• 1000t Newin Induced Draft Square Water Cooling Tower
  • 1000t Newin Induced Draft Square Water Cooling Tower
  • 1000t Newin Induced Draft Square Water Cooling Tower
  • 1000t Newin Induced Draft Square Water Cooling Tower
  • 1000t Newin Induced Draft Square Water Cooling Tower

1000t Newin Induced Draft Square Water Cooling Tower

Cooling Method: Counter Flow, Indirect Cooling
Ventilation Mode: Mixing Ventilation
Material: FRP
Air Contact Form: Wet and Dry
Air Contact Way: Open
Tower Shape: Square
Customization:

Contact Supplier

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
NST-1000H/M
Noise Level
Low
Application Fields
Manufacture
Certification
ISO
Condition
New
Nominal Flow
1000m3/H
Motor
7.5*4kw
Net Weight
8170kg
Running Weight
16150kg
Fan Diameter
2400mm
Water Pressure
42kpa
Usage
for Manufacture
Transport Package
20/40/40hq Container with Loose Packing
Specification
7000*7000*6100mm
Trademark
NEWIN
Origin
China
Production Capacity
15000 Sets/ Year

Product Description

The circulating working water heat energy of industrial cooling tower comes from the heat generated by the work done by industrial machinery. In the process of water heat exchange of the cooling tower, the surplus heat energy is distributed in the air in the form of evaporation, heat transfer, heat transfer by radiation, etc., and the circulating working water is sent to the main machine room.In terms of cooling efficiency, the cooling demand of industrial cooling tower is higher than that of air-conditioned cooling tower.Generally speaking, the circulating working water cooling temperature of industrial cooling tower reaches 10ºC-25ºC, or even higher, so this kind of cooling tower is also called high temperature cooling tower.
1000t Newin Induced Draft Square Water Cooling Tower
NSH series cooling towers are mainly used in the industrial manufacturing and processing system. Please refer to the information of this model below
1000t Newin Induced Draft Square Water Cooling Tower

NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

High Efficiency and Energy Saving
 Newin NSH series cooling tower using excellent quality PVC film as thermal interface material, corrosion resistant, no deformation, curved and diagonal design film effectively prolongs exchange time between high temperature water and air inside cooling tower, which makes air flow smoothly and resistance lower, meanwhile, making the water drift ratio lowest, furthermore, the axial and arc fan, specially designed basin with evenly distributed waterstoma, which highly improved heat exchange rate of cooling tower and lower the entire cooling tower's energy consumption and noise.

Excellent Design and Long lifetime
The shell of cooling tower adopts high quality and toughness glass fiber, beautiful shape, resistants to natural factors and chemical material erosion, looks brand new even after long time use. All the steel shelves are processed by immersive hot galvanized zinc and comply with British BSEN ISO1461:1999 standard, reducing the oxidation mostly, prolong the service life.

 Easy Installation, Reasonable and Practical Usage
 Newin NSH series counter flow square type cooling towers can be paralleled for multi-units, flexible combination, widely used. The body structure is tidy, standardized, compact and strong, which is easy for installation. The design and manufacture are all on basis of practical uses, so it can meet customers' requirement better with high quality.

Components Instruction

Infill
Specially designed S shape PVC infill is vacuum formed of 0.3 thickness or more thicker PVC film with excellent chemical and high distortion resistance, big coefficient of heat transfer, small wind resistance, high ventilation performance. We have different materials like PVC, UPVC, and PP  to suit different water temperature. 
Drift Eliminator
The NSH series cooling tower used easy installed PVC material drift eliminator to prevent water from splashing out of the cooling tower.  
Air Inlet Louver
The air inlet louver is used of F.R.P parts which makes the long life of the whole cooling tower. For sewage water cooling tower, we will use different type of the air inlet louver to meet customers' requirements.
Distribution Nozzles
The distribution nozzles used high quality A.B.S / PP material, easy to installed on the water pipe and make sure the water splashed evenly on the infill.
Steel Structure 
Hop-dip galvanized steel framework to keep the cooling tower great performance and long lifespan, good anti-corrosion, guarantee the use of more than 15 years. Stainless steel hardware parts are also available for options if somewhere special condition needed.  
Sea Water Solution 
Newin cooling tower also provide special solution for sea water application which is suite for sea side industrial project will use sea water as cooling media. Please contact your related sales manager for more details.  


1000t Newin Induced Draft Square Water Cooling Tower 1000t Newin Induced Draft Square Water Cooling Tower
                  Item Nominal 
Flow 
(m3/h)
Water
  Pressure   
  (× 104  Pa)
Exhuast  Fan Weight  (T) Overall  Dimension               
          (mm)
DB  (A)
  Model             Diameter 
(mm)
Motor   
(Kw× sets)
Net 
weight
Run.  
Weight
L W H
NST-80H/S 80 4 1500 3.0× 1 0.95 1.95 2000 2000 4000 60.0 
NST-100H/S 100 4 1800 4.0× 1 1.05 2.10  2250 2250 4000 60.0 
NST-125H/S 125 4 2100 4.0× 1 1.25 2.32  2500 2500 4000 61.0 
NST-150H/S 150 4 2100 5.5× 1 1.42 2.77  2750 2750 4000 62.0 
NST-175H/S 175 4.2 2400 5.5× 1 1.6 3.25  3000 3000 4200 62.0 
NST-200H/S 200 4.2 2400 7.5× 1 1.75 3.40  3250 3250 4200 62.5 
NST-250H/S 250 4.2 2400 7.5× 1 2.15 4.25  3500 3500 4200 63.0 
NST-300H/S 300 4.4 3200 11.0× 1 2.62 5.10  3750 3750 4400 63.5 
NST-350H/S 350 4.4 3200 11.0× 1 2.95 5.75  4000 4000 4400 64.0 
NST-400H/S 400 4.4 3400 15.0× 1 3.52 7.05  4500 4500 4400 64.5 
NST-160H/D 160 4 1500 3.0× 2 1.86 3.82  4000 2000 4000 62.0 
NST-200H/D 200 4 1800 4.0× 2 2.05 4.11  4500 2250 4000 62.0 
NST-250H/D 250 4 2100 4.0× 2 2.45 4.54  5000 2500 4000 63.0 
NST-300H/D 300 4 2100 5.5× 2 2.78 5.42  5500 2750 4000 64.5 
NST-350H/D 350 4.2 2400 5.5× 2 3.13 6.37  6000 3000 4200 64.5 
NST-400H/D 400 4.2 2400 7.5× 2 3.43 6.66  6500 3250 4200 65.0 
NST-500H/D 500 4.2 2400 7.5× 2 4.21 8.33  7000 3500 4200 65.0 
NST-600H/D 600 4.4 3200 11.0× 2 5.13 9.99  7500 3750 4400 66.5 
NST-700H/D 700 4.4 3200 11.0× 2 5.78 11.27  8000 4000 4400 66.0 
NST-800H/D 800 4.4 3400 15.0× 2 6.89 13.81  9000 4500 4400 66.5 
NST-240H/T 240 4 1500 3.0× 3 2.76 5.67 6000 2000 4000 63.0 
NST-300H/T 300 4 1800 4.0× 3 3.05 6.11  6750 2250 4000 63.0 
NST-375H/T 375 4 2100 4.0× 3 3.63 6.75  7500 2500 4000 64.0 
NST-450H/T 450 4 2100 5.5× 3 4.13 8.06  8250 2750 4000 65.5 
NST-525H/T 525 4.2 2400 5.5× 3 4.65 9.45  9000 3000 4200 65.5 
NST-600H/T 600 4.2 2400 7.5× 3 5.09 9.89  9750 3250 4200 66.5 
NST-750H/T 750 4.2 2400 7.5× 3 6.25 12.36  10500 3500 4200 66.5 
NST-900H/T 900 4.4 3200 11.0× 3 7.62 14.84  11250 3750 4400 67.0 
NST-1050H/T 1050 4.4 3200 11.0× 3 8.58 16.37  12000 4000 4400 67.5 
NST-1200H/T 1200 4.4 3400 15.0× 3 10.24 20.51  13500 4500 4400 68.0 
NST-320H/M 320 4 1500 3.0× 4 3.61 7.41  8000 2000 4000 64.5 
NST-400H/M 400 4 1800 4.0× 4 3.99 7.98  9000 2250 4000 64.5 
NST-500H/M 500 4 2100 4.0× 4 4.75 8.81  10000 2500 4000 65.5 
NST-600H/M 600 4 2100 5.5× 4 5.39 10.52  11000 2750 4000 67.0 
NST-700H/M 700 4.2 2400 5.5× 4 6.08 12.35  12000 3000 4200 67.0 
NST-800H/M 800 4.2 2400 7.5× 4 6.65 12.92  13000 3250 4200 68.0 
NST-1000H/M 1000 4.2 2400 7.5× 4 8.17 16.15  14000 3500 4200 68.0 
NST-1200H/M 1200 4.2 3200 11.0× 4 9.95 19.38  15000 3750 4400 68.5 
NST-1400H/M 1400 4.4 3200 11.0× 4 11.21 21.85  16000 4000 4400 69.0 
NST-1600H/M 1600 4.4 3400 15.0× 4 13.37 26.79  18000 4500 4400 69.5 
1000t Newin Induced Draft Square Water Cooling Tower
FRQ:
1. Are you manufacturer?
Answer: Yes we are a cooling tower manufacturer located in Guangdong Province China. With 18 years of manufacturing and OEM service for several brand of famous cooling tower.
2. Can you provide the cooling tower parts different with the specification in above showing form?
Answer: We can manufacturer and newly design for special order based on your provided specification and drawing or performance requirements.
3. What products are you manufacturing?
Answer: Cooling towers with its accessories (motor, steel frame, plastic components, FRP panel, PVC infill, motor, water pump, motor fan, control box for fan)
4. What is the delivery time?
Answer: For round type cooling tower below 300RT, we have stock in warehouse. Other type cooling tower, need to production upon receive the PO. Leading time 15 working days.
5. What is your quality warranty?
Answer: 1 year for motor, 2 years for steel parts, 5 years for FRP pannel. Free parts available during garrantee peroid.
6. How many workers working in your factory?
Answer: 270 workers at the end of 2013.
7. Do you have any production management system or certification for products.
Answer: ISO 9001: 2008 quality and environment management system certificates. CTI certificate for cooling towers.

1000t Newin Induced Draft Square Water Cooling Tower


For cooling tower information please visit to newinmachine.en.made-in-china.com
For cooling tower parts information please visit to newinmachine.en.made-in-china.com
 

Send your message to this supplier

*From:
*To:
avatar Mr. Kelvin
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now