• Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)
  • Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)
  • Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)
  • Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)
  • Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)
  • Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)

Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)

Customized: Yes
Brand: Newin
Usage: Replace for Marley, Bac, Newin Cooling Tower
Cooling Tower Type: Round(Bottle) Type Counter Flow Cooling Tower
Water Volume: 5000g/Kg
Fill Type: PVC Film
Samples:
US$ 20/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
Round type cooling tower(NRT-400)
Dimension
230mm, 250mm, 300mm, 350mm
Mateiral
PVC
Color
Green, Blue, Black, White
Transport Package
20/40/40hq Container with Loose Packing
Specification
CTI
Trademark
NEWIN
Origin
China
HS Code
3926901000
Production Capacity
1000000mt Per Year

Product Description

YN Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)

Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)

YN counter flow film fill is widely used in counter flow cooling towers, the product is a cellular block after bonding molding, according to the interval size of the tower bracket, cut into different sizes. Easy to installation. High heat exchange efficiency, small wind resistance, no-easy plugged. PVC, PP material are both available. Customers can choose according to cooling media temperature.

A type of corrugated PVC film fill, which is special design for counter flow round type cooling tower.It is most popular heat-eliminating medium for round type cooling tower.

Features
-This type of infill made flame retardant PVC material, thermal formed by mold.
-The corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill.
-The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space
   
Specification
Model--YN PVC,PP,UPVC
Max.length Depend on customer demand
Width 230/250/300/350 mm
Continuous
operation temperature
50ºC
Max. Application temp.
(short term)
60ºC
Color Green, black, blue, white (customizable)
Corrugation height 18/25 mm
Installation method Glued

Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container
Trade Terms: EXW, FOB, CFR,CIF, DDU.
Payment term: T/T, L/C, West Union
Minimum Order Quantity: 1000pcs

 

YN Infill Pictures --- cooling tower cross flow film fill
Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)



Packing & Shipment
Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)


PVC Plastic sheet(after molding) Physical and mechanical property 
No. Item symbol unit index test method
1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008
2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-1991
crosswise ≥38.0
3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91
crosswise ≥160
4 Folded in half Coldness
Resistance Temperature
ordinary type tb ºC ≤-8  DL/T 742-2001
Frigostabile type ≤-18
5 oxygen index OI   -- ≥30 GB/T 2406 1-2008

Cooling tower plastic parts code and standard
GB/T 1033-1986 plastic density and relative density experiment method
GB/T 1040-1992 plastic tensile performance test methods
GB/T 1633-1979 thermoplastic softening point (d) test method
GB/T 1843-1996 plastic cantilever beam impact test method
GB/T 2406-1993 plastic combustion performance test method, oxidation index
GB/T 13022-1991 plastic film tensile performance test methods
GB/T 1190-1991 plastic rectangular tear performance test methods

Counter cooling tower infill
Yn Series Cooling Tower Film Fill /Infill PVC (for bottle type cooling tower)


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
OEM/ODM Availability
Yes