CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC

Cooling Method: Cross Flow
Ventilation Mode: Mechanical Ventilation
Material: FRP
Air Contact Form: Wet
Air Contact Way: Open
Tower Shape: Square
Customization:

Contact Supplier

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
RT-175/S
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, ISO, CTI
Condition
New
Applications
Industrial Water Enhance Cooling/ HVAC etc
Water Pump Motor
IP55, Insulation Class F
Character
Energy Saving and Easy Maintainance
Drift Loss
Less 0.002%
Structure
Hdgs/ Ss/ FRP and So on
Casing/ Body
Hdgs/ Ss/ FRP and So on
Transport Package
20/40/40hq Container with Loose Packing
Specification
customized
Trademark
NEWIN
Origin
China
HS Code
841950
Production Capacity
15000 Sets / Year

Product Description

CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC
CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC
NST series cross flow square  cooling tower is available in capacity for single cell from 100 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements.This cooling tower is highly used in heating, ventilation, air-conditioning, and light to medium processing applications.

CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC
Features

♦Space Saving, Light-duty Structures
Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly.

♦Energy Saving, Low Noise
Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Double speed motor for optional to power saving according to customers' special requirements.
Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). 

♦Good Corrosion Resistance
Tower casing, tank and panel are made up of high corrosion resistance performance FRP material, and Galvanized steel structure improves the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life.

♦Convenient combination and Easy Maintenance
Combinations can be used to meet the requirements of different working condition.If limited space in end user, we can also design for the special cooling tower to meet users' requirements for the performance of thermal and noise.
 

Components Instruction

CASING AND BASIN

Fiberglass reinforced polyester (FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed.
 

FAN & DRIVING SYSTEM

Adopting low speed, big chord length and width of blade fan, with stable wind speed, low noise, and high efficiency, etc. Enough air flow can be easily get at low rotating speed of the fan, what's more, blade angle can  be  adjusted according to different climate condition. Used aluminum alloy fan blades, solid fan or hollow type available for different customers' request.
Using motor with IP55 protection grade, F class insulation grade, smooth operation, low failure rate. Options: Siemens, ABB
 

DISTRIBUTION SYSTEM

Using the unique overflow device to realize smooth and even water distribution under different sustem load, the device completely eliminates the drift loss of coolig tower. Hot water basin cover avoids water pollution by foreign objects falling into hot basin. Meantime, it avoids direct sunlight and inhabit growth of algae.
 

FILL PACKING

Used high quality & improved performance PVC with good material, it is high cooling efficiency and anti-corrosive & UL V-0. Brand new PVC materials, integrated eliminators and louvers. The infills are hanging type, environmental friendly and  big coefficient of heat transfer, good hydrophilicity. Small wind resistance, high ventilation performance. Special material for option if high entering water temperature.
 

FRAME STRUCTURE AND FASTENERS

Leading structure design and high-quality materials to make frame structure and fasteners, the standard configuration of structure and fasteners is superior hot-dip galvanized steel, good anti-corrosion, design lifespan is more than 15 years. Stainless steel or F.R.P frame structure available for poor water soltion, and SUS304 or SUS316L for fasteners.  

CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC

Optional Accessories

♦ Noise reduction upgrade                       ♦ Anti-Freeze heater                             
♦ Vibration isolator & rubber mat             ♦ Handrail & Safety caged ladder
♦ High-temperature upgrade                   ♦ Dual-speed Motor & VFD motorAnti-Freeze heater

Technical Specification of NST Series Cooling Tower
 
Model Cooling Capacity
(RT)
Motor
kw
Fan Diameter
mm
Dimension (mm) Water Inlet
DN
Water Outlet
DN
Weight (kg)
H W L Dry Wet
NST-19-A16-3A12-C1 100 3(A) 1600 3680 3800 1900 100*2 125 1250 2650
NST-22-B16-3A12-C1 125 4(B) 1600 380 3800 2200 125*2 150 1350 2750
NST-22-B18-3A14-C1 150 4(B) 1800 4080 4010 2200 125*2 150 1450 2950
NST-26-C22-3A14-C1 175 5.5(C) 2200 4080 4420 2600 125*2 200 1550 3250
NST-26-C22-3A15-C1 200 5.5(C) 2200 4280 4420 2600 150*2 200 1720 3530
NST-26-D22-3A16-C1 225 7.5(D) 2200 4480 4420 2600 150*2 200 1820 4170
NST-30-D24-3A16-C1 250 7.5(D) 2400 4680 4620 3000 150*2 250 2280 4700
NST-30-D24-4A14-C1 300 7.5(D) 2400 4280 5230 3000 150*2 250 2620 5470
NST-30-E24-4A16-C1 350 11(E) 2400 4680 5230 3000 150*2 250 2750 5700
NST-33-E28-4B18-C1 400 11(E) 2800 5130 5640 3300 150*4 300 3050 6600
NST-33-F28-4B20-C1 450 15(F) 2800 5500 5640 3300 150*4 300 3450 7000
NST-38-F28-4B20-C1 500 15(F) 2800 5500 5640 3800 150*4 300 3750 7800
NST-38-F34-4B20-C1 550 15(F) 3400 5630 6240 3800 150*4 350 4250 8600
NST-46-G34-4B20-C1 600 18.5(G) 3400 5630 6240 4600 150*4 350 4850 10200
NST-46-G36-4B22-C1 700 18.5(G) 3600 6030 6450 4600 150*4 350 5250 14500
NST-51-I36-4B22-C1 800 30(I) 3600 6080 6450 5100 200*4 400 5650 15500
NST-53-I42-4B24-C1 900 30(I) 4200 6530 7060 5300 200*4 400 6450 17800
NST-53-J42-4B26-C1 1000 37(J) 4200 6930 7440 5300 200*4 400 7150 19500

CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC
NEWIN NST cooling tower project cases


CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC

Cooling Tower Shipment

CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC

NEWIN COOLING TOWER


CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC
CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC
CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC


CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC CTI Industrial Cross Flow FRP Modules Cooling Tower for HVAC

Send your message to this supplier

*From:
*To:
avatar Mr. Kelvin
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now