Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
  • Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
  • Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
  • Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
  • Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
  • Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
Find Similar Products
  • Overview
  • Features
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NBR
Condition
New
Hardness
Hardened Tooth Surface
Installation
90 Degree
Layout
Coaxial
Gear Shape
Conical - Cylindrical Gear
Step
Four-Step
Type
Gear Reducer
Application
Cooling Tower
Transport Package
Wooden Case
Trademark
NEWIN
Origin
China
HS Code
8419500090
Production Capacity
1000000mt Per Year

Product Description

High-Quality Cooling Tower Belt Pulley Reducer: Experience unparalleled reliability and performance with our top-of-the-line belt pulley reducer, designed to enhance the efficiency of your cooling tower operations.

NBR & NSR: These exceptional materials provide superior durability and resistance, ensuring your cooling systems operate smoothly and effectively in all conditions. The belt type reduction drive is a versatile solution, perfect for a variety of applications. It utilizes the tension in the pulley systems of both the driving and driven wheels, seamlessly transferring power through a mechanical transmission. Notably, it features a straightforward design and stable transmission capabilities, with the added benefits of vibration absorption and buffering. This system excels in long-distance power transmission between shafts, offering a cost-effective solution that requires no lubrication and minimal maintenance. It is widely utilized in cooling towers and various mechanical equipment due to these outstanding attributes.

This complete belt drive system, featuring a motor pulley, fan pulley, and V belts, ensures optimal performance and reliability for your cooling tower applications. Our designs accommodate diverse installation needs with two distinct types: upright mounting and upside-down mounting. Each type is meticulously crafted to meet the specific requirements of different cooling tower configurations.
Robust Cooling Tower Belt Pulley Reducer for Long-Lasting UseRobust Cooling Tower Belt Pulley Reducer for Long-Lasting Use

Features

Our Superior Belt: Crafted with precision by a well-recognized manufacturer, this belt embodies exceptional elasticity, offering unparalleled adaptability. Easily select the desired length within a specified range to perfectly meet the center distance requirements of even the most demanding working conditions.

Belt Pulley Reducer: Experience the excellence of our belt pulley reducer, boasting a simple yet robust structure that ensures stable and reliable operation. Delight in the reduced vibration and low noise levels, along with an extended service life, making it a quintessential choice for those who prioritize durability.
Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use

Drive type Drive efficiency Main components Maintenance Note.
Belt 90~95% Belt, motor pulley, fan pulley, big bearing Check belt tightness to prevent slipping.
Belt damaged need to be replaced.
Low installation requirement that it just need to keep the belt level.
Product Parameters

Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use

Model Nos.of
Groove
H H1 H2 H3 Ø1 Ø2 Ø3 Ø4 N-ØD K T
NBR-5 2 45 50 175 76 355 300 263 34 4-Ø13 37 8
NBR-6 3 65 60 225 105 456 348 300 38 4-Ø14 41 8
NBR-8 4 85 62 265 120 456 428 390 50 6-Ø16 53 12
NBR-10 4 85 62 310 135 608 500 450 50 4-Ø16 53 12
NBR-12 5 105 62 310 143 660 500 450 60 4-Ø16 63 12
NBR-14 6 125 62 320 153 660 500 450 75 6-Ø16 79.5 20
 
Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
Model Nos.of
Groove
H H1 H2 H3 Ø1 Ø2 Ø3 Ø4 N-ØD K T
NSR-8 4 85 55 420 105 430 580 540 38 4-Ø14 41 8
NSR-10 4 85 55 480 117 430 580 540 50 4-Ø14 53 12
NSR-12 4 85 205 700 133 608 730 688 50 4-Ø16 53 12
NSR-14 5 105 205 700 143 660 765 720 60 4-Ø18 63 12
NSR-16 8 165 205 800 153 660 765 720 75 4-Ø18 79.5 20
NEWIN Manufacturing Base

Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
NEWIN FACTORY
Our state-of-the-art manufacturing base is strategically located in Huizhou, Guangdong, spanning an impressive 10,000 square meters. This expansive facility is the heart of our innovative production capabilities.

ISO CERTIFICATION
NEWIN proudly holds the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, underscoring our commitment to excellence and sustainable practices.

WORKSHOPS
Welding Workshop - Where precision meets craftsmanship in every weld.
Filler Thermoforming Workshop - Crafting the components that power our cutting-edge cooling solutions.
Sheet Metal Processing Workshop - A hub of innovation where raw materials are transformed into pioneering products.
Cooling Tower Assembly Workshop - The birthplace of our robust cooling solutions, ensuring quality and reliability.

TESTING
Independent Testing LAB - Where rigorous testing ensures our products meet the highest standards of quality and performance.

Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN - These series represent our Closed Type Cooling Tower Solutions, designed for optimal efficiency. Closed Type Cooling Tower Series
· NSH/ NST - Our Open Type Cooling Tower Series, engineered for performance and durability. Open Type Cooling Tower Series
· NTG - An Industrial Type Cooling Tower Series, capable of handling the most demanding industrial applications. Industrial Type Cooling Tower Series
· NECN/NECH - Evaporative condensers, merging efficiency with reliability. Evaporative condenser
· NWFL - Our Dry Air Cooler, designed for superior performance in diverse environments. Dry Air Cooler

Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
NEWIN is your trusted partner, offering a comprehensive range of cooling tower accessories to enhance and maintain any cooling tower system. Contact us to tailor the perfect accessories for your specific needs.

CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.) - Essential for powering efficient cooling.
· Water distribution (nozzles/ drift eliminator etc.) - Ensuring even and effective water management.
· Heat exchange (PVC infills/ cooling coil etc.) - Critical components for optimal heat transfer.
· Other accessories (air inlet louver/ valve etc.) - Enhancing functionality and performance of your cooling tower.
 
Packaging & Shipping

Our open type cooling towers are meticulously prepared for shipment to ensure their pristine condition and optimal functionality upon arrival. With precision packaging, each unit embarks on its journey to your location, safeguarding the innovative technology within and guaranteeing unparalleled performance durability.

Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
The delivery of our closed type cooling towers is handled with exceptional care and attention, ensuring each product reaches you in perfect working order. Through expert packaging solutions, these sophisticated units are protected during transit, preserving the integrity of their advanced design and guaranteeing superior efficiency and longevity.
Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
Technical Strength& Standards

Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use
Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use

Certifications

Robust Cooling Tower Belt Pulley Reducer for Long-Lasting UseRobust Cooling Tower Belt Pulley Reducer for Long-Lasting UseRobust Cooling Tower Belt Pulley Reducer for Long-Lasting UseRobust Cooling Tower Belt Pulley Reducer for Long-Lasting Use

Robust Cooling Tower Belt Pulley Reducer for Long-Lasting Use

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More