Discover the unparalleled NEWIN NWF Series Mixed Flow Closed Type Cooling Tower, a marvel of modern engineering.
NWF: The epitome of advanced cooling technology. This elite series of closed cooling towers merges advanced composite flow cooling innovations to ensure steadfast operation, fostering energy efficiency and environmental stewardship. As the spray water cools the heat exchange coil, it descends into the cold water basin through a PVC heat exchange layer, profoundly reducing the tower's internal temperature while significantly decreasing the noise typically produced by water directly spilling into the basin.
Unrivaled High-Efficiency Mixed Flow Closed Circuit System
Flawless and Seamless Operation
The cooling process for the fluid medium flows through a supremely efficient serpentine coil heat exchanger. An uninterrupted external spray system keeps the coil surface continuously moist, enabling ceaseless cooling. This permits the cooled medium to efficiently transfer heat with the spray water via a partition wall heat exchanger, constructing a closed loop for supreme cooling effectiveness. Fresh, low-temperature dry air enters the tower laterally, crossing vertically with the spray water's flow, orchestrating a composite heat transfer powered by robust fans. After the heat exchange, the high-temperature saturated air exits the tower, and the spray water undergoes a secondary heat transfer within a PVC heat exchange layer before gathering in a water collection basin, thereby elevating the cooling efficiency to unprecedented levels.
Exclusive and Distinctive Advantages
> TheRevolutionary Mixed Flow Closed-Loop Circulation Systemguarantees media purity, slashes maintenance costs, and preserves precious water resources, while delivering unparalleled cooling performance.
>The dynamic fusion of a stainless steel coil heat exchanger with a PVC heat exchange layerprovides not only superior efficiency but also an aura of elegance. This visionary design amplifies heat transfer areas, heightens heat exchange efficiency, and contributes to noise reduction.
> The brilliantly engineered single-side air intake design substantially diminishes noise emissions at the tower's rear, rendering itabsolutely ideal for noise-sensitive settings.
> The product features asleek and space-saving design,allowing for effortless integration of multiple cooling towers.
Features
COOLING TOWER PARTS
1. Axial Flow Fan
The aluminum alloy axial flow fan is engineered for low noise performance, stability, and high efficiency. The motor's top-tier protection with an IP55 rating and F-grade insulation ensures exceptional safety and reliability, making it an ideal choice for demanding operations.
2. External Spray System
This system expertly sprays cool water onto the heat exchange coil, maintaining a consistently wet surface for superior cooling effectiveness and efficiency.
3. Stainless Steel Heat Exchange Coil
Our stainless steel coils provide unparalleled heat exchange efficiency and exceptional corrosion resistance. Their lightweight design contributes to a longer equipment lifespan, while their recyclability underscores our commitment to environmental sustainability.
4. MAH PVC Fill Film (PVC Heat Exchange Layer)
This PVC filler integrates seamlessly with the air inlet grille and drift eliminator, ensuring consistent air intake and significantly reducing water drift loss. The unique surface texture maximizes heat exchange surface area, boosting efficiency. Upgrading to high-temperature materials is possible to meet specific project conditions.
5. MBD PVC Drift Eliminator
Specially designed for closed cooling towers, this drift eliminator excels in extracting airborne water droplets with minimal wind resistance and a remarkable 99.99% capture rate, assuring optimal heat transfer performance.
6. Air Inlet Louver
This louver ensures that cool, dry air is drawn in evenly and flows through the coil and PVC heat exchange layer, reducing sun exposure and inhibiting microbial growth efficiently.
7. Heavy-duty Construction
Constructed with a high-quality Z700 galvanized steel frame and shell,it offers outstanding corrosion resistance. For extreme conditions, optional SUS314/316 or NWN-Armour anti-corrosion coated steel provides unparalleled protection.
8. Access Door
Facilitates entry to the tower's inner maintenance platform, ensuring easy access for routine checks and essential upkeep.
The presence of an inspection platform within the cooling tower significantly enhances convenience for conducting thorough inspections and efficient maintenance.
Product Parameters
Design Condition
NWF |
Dimension (mm) |
Weight (kg) |
Model |
L |
W |
H |
Dry |
Wet |
NWF-120-Z7-S |
2300 |
1910 |
2850 |
843 |
1935 |
NWF-180-Z7-S |
2300 |
1910 |
2930 |
883 |
2006 |
NWF-230-Z7-S |
2850 |
2110 |
2930 |
1140 |
2701 |
NWF-290-Z7-S |
3550 |
2110 |
2930 |
1377 |
3396 |
NWF-350-Z7-S |
4150 |
2110 |
2930 |
1601 |
4013 |
NWF-450-Z7-S |
4550 |
2250 |
3480 |
2055 |
4706 |
NWF-600-Z7-S |
4550 |
2250 |
3720 |
2197 |
4899 |
NWF-750-Z7-S |
5200 |
2250 |
4270 |
3201 |
6920 |
NWF-900-Z7-S |
5200 |
2250 |
4490 |
3549 |
7535 |
NWF-1000-Z7-S |
5200 |
2870 |
4490 |
4045 |
8589 |
NWF-1150-Z7-S |
5900 |
2870 |
4540 |
4536 |
9677 |
NWF-1450-Z7-S |
5900 |
3150 |
4690 |
5321 |
12230 |
NWF-1750-Z7-S |
6500 |
3150 |
4690 |
5943 |
13744 |
NWF-2300-Z7-S |
7500 |
3250 |
4900 |
6963 |
15214 |
Optional Various Additional Functions
Unlock the full potential of your cooling system with our versatile range of optional features. Experience the ultimate in operational efficiency with our two-speed and VFD variable frequency motors, designed for flawless performance. Enhance safety with our advanced vibration cut-off switch, and ensure peak maintenance with cutting-edge electronic descaler technology. Enjoy the benefits of modern water treatment systems and an anti-freeze automatic heating solution, perfect for extreme climates. Elevate your environment with superior noise reduction upgrades. Our thoughtfully designed external maintenance platforms, equipped with secure guardrails and convenient installation and maintenance booms, ensure both enhanced safety and streamlined operations.
Affordable and Effective Anti-Corrosion Solution
NWN-Armour Anti-corrosion Technology
By integrating our NWN-Armour anti-corrosion technology, our products boast exceptional corrosion resistance, rivaling that of stainless steel. This innovative coating provides a cost-effective and robust alternative to traditional stainless steel options, offering unparalleled protection and longevity. Choose our solution for unmatched durability and performance.el.
The Closed Circuit Mixed Flow Cooling Tower from Newin (Guangdong) Machinery Co., Ltd. is meticulously engineered to cater to a diverse range of industrial sectors, ensuring optimal performance and unmatched efficiency. This versatile cooling solution stands as an indispensable asset in the Energy industry, providing steadfast and efficient cooling for power generation systems. Within the Pharmaceutical industry, it guarantees the essential environmental conditions necessary for sensitive processes and products. The HVAC sector benefits from its remarkable capacity to maintain desired temperature levels, significantly enhancing comfort and efficiency across various buildings. The Chemical industry places its trust in its robust design to support and execute complex cooling requirements with unwavering safety and reliability. In the fields of Machinery manufacturing and Metal processing, it plays a crucial role in preserving the integrity of high-performance machinery and processed metals. For manufacturers of Plastic products, it ensures consistent quality and precision, resulting in superior outputs. As a cornerstone of Industrial cooling, this system adeptly addresses the unique demands across various industrial applications, delivering a tailored and exceptional cooling experience. Lastly, in the Food processing industry, it guarantees that products are processed under ideal temperature conditions, thus maintaining freshness and quality throughout the entire production process.
NEWIN Manufacturing Base
Discover the Efficiency and Precision of the NEWIN FACTORY
Nestled strategically in Huizhou, Guangdong, our sprawling manufacturing base covers an impressive 10,000 square meters, meticulously designed to consistently deliver outstanding quality and innovation.
Our Prestigious ISO CERTIFICATION: A Commitment to Quality and Sustainability
With pride, we uphold the esteemed ISO9001:2015 Quality Management System Certification alongside the ISO14001:2015 Environmental Management System Certification, ensuring our commitment to excellence and environmental stewardship.
Explore Our State-of-the-Art WORKSHOPS: Where Innovation Meets Craftsmanship
Step into Our Cutting-Edge Welding Workshop: Precision at Its Best
Experience the Advanced Filler Thermoforming Workshop: Where Quality Shapes
Discover the Precision of Our Sheet Metal Processing Workshop
Join Us at the Efficient Cooling Tower Assembly Workshop: Crafting Excellence
Engage in Our RIGOROUS TESTING Standards: Ensuring Unmatched Quality
Our Independent Testing LAB: Rigorously Ensuring Superior Quality Output
NEWIN COOLING TOWERS: Experience a Spectrum of Excellence in Every Model
·
NWN/ NWF/ NCFN Series Explore Our Renowned Closed Type Cooling Tower Series, Defined by Quality
·
NSH/ NST Series Delve into Our Innovative Open Type Cooling Tower Series, Showcasing Cutting-Edge Design
·
NTG Series Our Specialized Industrial Type Cooling Tower Series: Engineered for Performance
·
NECN/NECH Series Efficient Evaporative Condenser Systems: Excellence in Every Drop
·
NWFL Series The Advanced Dry Air Cooler: Leading-edge Cooling Solutions
NEWIN provides a comprehensive assortment of cooling tower accessories, readily available to meet all maintenance and replacement requirements, regardless of size or type. Reach out to us for bespoke accessory solutions tailored to your cooling tower.
OUR INCLUSIVE RANGE INCLUDES:
· Fan Drive System: An All-Inclusive Set (featuring fan, fan stack, reducer, motor, shaft, and more)
· Water Distribution Components: Essential Elements (including nozzles and drift eliminator)
· Heat Exchange Essentials: Core Components (such as PVC infills and cooling coil)
· Additional Accessories: Vital Extras (such as air inlet louvers and valves)
Packaging & Shipping
Open Type Cooling Towers Shipment: Embark on a journey of seamless logistics excellence with our state-of-the-art open type cooling towers. Each unit is meticulously packed to endure the rigors of transit, ensuring that the renowned superior performance and unmatched reliability of Newin (Guangdong) Machinery Co., Ltd. is impeccably upheld. Our streamlined shipping solutions are designed to guarantee timely delivery, ensuring your projects stay on track and on schedule without a hitch.
Closed Type Cooling Towers Shipment: Experience the epitome of careful handling and meticulous attention with the shipment of our closed circuit mixed flow cooling towers. Each cooling unit is expertly secured and packaged to avert any transit damage, delivering a product that epitomizes the esteemed quality and durability you expect from Newin (Guangdong) Machinery Co., Ltd. Rely on us for delivery that is as swift as it is reliable, ensuring your peace of mind every step of the way.
Technical Strength& Standards
Certifications