NEWIN NSH-F series FRP Counter Flow Cooling Tower
NSH-F series F.R.P ( Fiber Reinforced Plastic ) framework cooling tower is a type of open circuit cooling tower designed to special applicant in corrosive liquid cooling process. such as, sea water, chemical fluids, wood industrial, steel plant water, waste water, waste water treatment etc. due to its higher corrosion resistance, design life is up to 30 years. The pultruded structural fiberglass is a good replacement material of old treated wood structure cooling tower.
Components Instruction
F.R.P ( Fiber Reinforced Plastic)Framework
The pultruded F.R.P ( Fiber Reinforced Plastic) profiles has good strength which can compare to carbon steel profiles, but better acid-base resistance property.
Cooling Tower Water Distribution System
Using large orificum non-clog ABS nozzles mounted on high corrsion resistant FRP spray pipes, multi spray patterns ensure proper water coverage to increase the heat exchange surface, so as to improve the cooling capacity of the cooling tower.
High Efficient Fan Drive System
Using big brand axial flow fan, stable, high efficiency, low noise and corrosion resistance.
LAN Series Fill Packing and EVD Series Drift Eliminator
Using NEWIN LAN series Fill packing & EVD series Drift Eliminator, made of advanced self-extinguishing PVC materials with high thermal performance, the standard heat temperature of 55ºC.Special materials for high temp. condition is optional.
- LAN series Fill packing
The special drainage tips of LAN series cooling tower infill allow high water loading without excessive pressure drops, LAN filler sheets are bonded into the fill blocks and used in the cooing tower, the structural integrity of the fills is greatly enhanced and superior heat transfer.
- EVD series Drift eliminator
EVD series Drift eliminators are installated above the water distribution system and efficiently capture large water droplets caught in the cooling tower air stream, maximum drift capture and improving thermal transfer performance.
Optional Accessories
♦ Noise reduction upgrade ♦ Anti-Freeze heater
♦ Vibration isolator & rubber mat ♦ Stainless steel framework / bolts and nuts (304 / 316)
♦ High-temperature upgrade ♦ Dual-speed Motor & VFD motorAnti-Freeze heater
Technical Specification of NSH Series Cooling Tower
Model |
Cooling Capacity
(RT) |
Motor
kw |
Fan Diameter
mm |
Dimension (mm) |
Water Inlet
DN |
Water Outlet
DN |
Weight (kg) |
H |
W |
L |
Dry |
Wet |
NSH-88-A16-319-C1 |
100 |
1600 |
3 |
2000 |
2000 |
3600 |
150 |
150 |
1150 |
2370 |
NSH-99-B18-319-C1 |
150 |
1800 |
4 |
2250 |
2250 |
3650 |
150 |
150 |
1250 |
2550 |
NSH-1010-B22-319-C1 |
175 |
2200 |
4 |
2500 |
2500 |
3700 |
150 |
150 |
1450 |
2980 |
NSH-1111-C22-319-C1 |
200 |
2200 |
5.5 |
2750 |
2750 |
3800 |
150 |
150 |
1620 |
3300 |
NSH-1212-C24-319-C1 |
250 |
2400 |
5.5 |
3000 |
3000 |
4100 |
200 |
200 |
1800 |
4690 |
NSH-1313-D24-319-C1 |
300 |
2400 |
7.5 |
3250 |
3250 |
4350 |
200 |
200 |
1950 |
4515 |
NSH-1414-D28-319-C1 |
400 |
2800 |
7.5 |
3500 |
3500 |
4350 |
200 |
200 |
2350 |
5685 |
NSH-1515-E28-319-C1 |
450 |
2800 |
11 |
3750 |
3750 |
4750 |
250 |
250 |
2820 |
6450 |
NSH-1616-E34-319-C1 |
500 |
3400 |
11 |
4000 |
4000 |
4800 |
250 |
250 |
3150 |
6990 |
NSH-1818-F34-319-C1 |
600 |
3400 |
15 |
4500 |
4500 |
5250 |
300 |
300 |
3720 |
8250 |
NSH-2020-F34-319-C1 |
700 |
3400 |
15 |
5000 |
5000 |
5400 |
300 |
300 |
3950 |
8480 |
NSH-2020-F38-319-C1 |
800 |
3800 |
15 |
5000 |
5000 |
5400 |
300 |
300 |
4350 |
9580 |
NSH-2121-F38-319-C1 |
900 |
3800 |
18.5 |
5250 |
5250 |
5700 |
350 |
350 |
4880 |
10620 |
NSH-2222-H42-319-C1 |
1000 |
4200 |
22 |
5500 |
5500 |
5900 |
350 |
350 |
5660 |
11780 |
NSH-2424-I42-319-C1 |
1200 |
4200 |
30 |
6000 |
6000 |
6550 |
400 |
400 |
6720 |
13700 |
NSH-2626-I47-319-C1 |
1300 |
4700 |
30 |
6500 |
6500 |
6550 |
400 |
400 |
7750 |
15670 |
NSH-2828-I47-319-C1 |
1500 |
4700 |
30 |
7000 |
7000 |
6950 |
450 |
450 |
8400 |
17270 |
NEWIN NSH cooling tower project cases
Factory
Cooling Tower Shipment
NEWIN COOLING TOWER