High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

Product Details
Customization: Available
After-sales Service: Consult Newin Sales Representative
Warranty: Consult Newin Sales Representative

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
  • High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
  • High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
  • High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
  • High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
  • High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
Find Similar Products
  • Overview
  • Advantages
  • Components
  • Reference Projects
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NCFN-GS
Cooling Method
Dry Wet Hybrid Cooling
Ventilation Mode
Forced Draft
Material
Aluminum Zinc
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ordinary
Application Fields
Industial & Air Conditioning
Certification
ISO, CE, CTI
Condition
New
Model
Ncfn-GS-L-850/1150/1300
Cooling Capacity
863kw to 1793kw
Free Cooling
Capacity 120kw to 247kw ( Under 12/7/0 Celsius)
Fan Motor Without Silencer
11kw to 37kw
Transport Package
Container
Specification
CE, UL, CTI
Trademark
NEWIN
Origin
Shenzhen China
HS Code
84195000
Production Capacity
1000sets/Month

Product Description

Introducing an Advanced Dry Wet Hybrid Cooling Tower: the epitome of efficient heat dissipation! This state-of-the-art cooling marvel is engineered to meet the most demanding cooling requirements with unparalleled efficiency, effectively supporting your operations by maintaining optimal temperatures.

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
NCFN-GS Series Dry-Wet Hybrid Forced Draft Closed Cooling Tower

The NCFN-GS series cooling system is a marvel of engineering that harmoniously combines the benefits of both wet and dry cooling technologies. It provides exceptional cooling performance, significantly reduces energy usage, and conserves water effectively, adapting seamlessly to various ambient temperature conditions. This cooling tower is the perfect fit for challenging environments such as arid desert landscapes and extreme cold climates. Moreover, its innovative forced draft system ensures ultra-quiet operation, making it the ideal cooling solution for areas with poor ventilation and locations sensitive to noise disturbances.
High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
 
Advantages

ADVANTAGE

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

Dry-Wet Hybrid Cooling Mode

The NCFN-GS cooling tower is engineered with an innovative capability to seamlessly transition its operational modes, adapting gracefully to the ever-changing ambient temperatures.

Dry Cooling Mode
As the mercury dips below -10ºC or the output temperature registers lower than the set point, the spray pump halts, allowing the cooling tower to seamlessly switch to an efficient dry cooling mode. This smart transition reduces water evaporation in colder seasons and offers an economically sound alternative to refrigeration, delivering cooling efficiency with notable savings in both water and energy.

Wet Cooling Mode
When the thermometer climbs past a specific threshold of -2ºC, or the output temperature exceeds a predetermined level, the spray pump springs into action, engaging the cooling tower in the dynamic wet cooling mode. This process ensures robust evaporative cooling, delivering substantial cooling capacity when it's needed the most.

 

Water saving, Energy conservation, Environmental protection

> Compared to traditional wet cooling towers, this advanced system significantly reduces spray water usage, thereby decreasing overall water consumption, promoting superior sustainability.
> Through the implementation of cutting-edge intelligent control systems and state-of-the-art cooling technology, energy consumption is optimized, leading to remarkable reductions in electricity usage and enhanced energy utilization.
> The dry-wet hybrid cooling system efficiently minimizes water mist emissions, contributing to a lower environmental footprint and bolstering eco-friendliness.

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

Operation & Maintenance Cost Saving

> The closed-circuit circulation system maintains the purity of the cooling medium, significantly reducing water contamination and treatment costs. Moreover, utilizing the dry cooling mode in winter months greatly minimizes the risk of freezing, ensuring the components of the cooling tower are safeguarded. This strategic approach not only slashes operation and maintenance expenses but also guarantees the enduring, stable performance of the equipment.
> With factory assembly, transportation and installation are streamlined and efficient, ultimately conserving valuable time and effort in the setup process.


Components

MAIN PARTS

Forced Draft Centrifugal Fan Drive System

Our state-of-the-art Forced Draft Centrifugal Fan Drive System features a premium centrifugal fan, proudly bearing the AMCA Seal for excellence in air performance, sound control, and FEG standards. Equipped with advanced wheel blades and a belt pulley drive mechanism, each fan is meticulously subjected to stringent static and dynamic testing, achieving a perfect balance at G2.5 grade. This ensures supreme heat transfer performance within our cooling towers, all while maintaining an impressively low noise level. Capable of handling vast air volumes, the flow range extends from 1000m3h-100000m3h. This fan system stands out for its unparalleled stability, exceptional efficiency, whisper-quiet operation, and remarkable energy conservation.

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

Key Parts for Closed Circuit System And Dry-Wet Cooling Modes.

Within our sophisticated system, the fluid medium requiring efficient cooling circulates seamlessly through the
fin tube heat exchanger and stainless steel heat exchange coil enclosed within our closed circuit system. This innovative design ensures pristine cleanliness, significantly reduces water treatment and maintenance costs, and conserves valuable water resources, all while providing high-efficiency cooling.

Fin tube heat exchanger and stainless steel heat exchange coil serve as not only indispensable components of closed circuit systems but also as crucial elements of our Dry-Wet Cooling Modes.
 

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

Finned Tube Heat Exchanger

Crafted with precision, our finned tube heat exchanger incorporates stainless steel tubes combined with aluminum spiral fins, offering exceptional anti-corrosion properties and stability. The innovative structural design maximizes the heat exchange area, enhances heat transfer efficiency, and facilitates comprehensive air exchange with the fin tube. This ultimately leads to water-saving operation during both dry and wet cooling stages. Additionally, it effectively prevents the formation of 'white smoke' during winter operations, ensuring a superior working environment and extending the equipment's operational life.

 


Stainless Steel Heat Exchange Coil

Our premium heat exchange coil features a stainless steel serpentine bending tube and a robust framework, guaranteeing outstanding thermal performance and ensuring full contact with sprayed water for optimal heat exchange and efficient cooling. These stainless steel pipes are not only corrosion-resistant but also lightweight and recyclable, making them an eco-friendly choice.

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

High Capacity Hybrid Cooling Tower for Extreme Cooling NeedsOptional Various Additional Functions
Enhance your system with numerous optional features such as: Two-speed & VFD variable frequency motors, vibration cut-off switches, electronic descalers, advanced water treatment equipment, an anti-freeze automatic heating system, noise reduction upgrades, and external maintenance platforms with guardrails. Additionally, consider the installation and maintenance boom for comprehensive support.
 

Cost-effective Anti-Corrosion Solution
NWN-Armour Anti-corrosion Technology

Our products, treated with the cutting-edge NWN-Armour anti-corrosion coating, boast remarkable resistance to corrosion, rivaling the durability of stainless steel. This provides a highly cost-effective alternative to stainless steel.
High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
Reference Projects

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

Product Parameters

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

Model Wet Cooling Free Cooling Fan Motor Spray Pump Total Dimension
(without silencer)
Weight
Fluid flow Cooling capacity Capacity
12/7/0ºC
Power Power L W H Shipping Operation
m³/h kW kW kW kW mm mm mm kg kg
NCFN-GS-L-510-F 66 340 77 5.5  2.2  4680 2200 2920 3468 5184
NCFN-GS-L-510-S 66 340 108 7.5  2.2  4680 2200 3040 3636 5421
NCFN-GS-L-640-S 97 499 111 7.5  2.2  4680 2200 3240 3908 5812
NCFN-GS-L-640-E 97 499 142 11.0  2.2  4680 2200 3360 4082 6041
NCFN-GS-L-1000-F 119 612 139 15.0  4.0  6920 2200 2990 5438 8061
NCFN-GS-L-1000-S 119 612 211 18.5  4.0  6920 2200 3110 5647 8213
NCFN-GS-L-1250-S 175 900 218 22.0  4.0  6920 2200 3310 5898 8698
NCFN-GS-L-1250-E 175 900 273 30.0  4.0  6920 2200 3430 6107 9019
NCFN-GS-L-1560-F 225 1158 206 37.0  5.5  7520 2400 3190 6291 9928
NCFN-GS-L-1560-S 225 1158 273 37.0  5.5  7520 2400 3310 6534 10311
NCFN-GS-L-1560-E 225 1158 273 45.0  5.5  7520 2400 3430 6777 10694
Note:
1. Standard Design Working Condition: Fluid in/out temperature: 35/30ºC.
2. Standard design ambient wet/dry bulb temperature: 21/31ºC.
3. Above data sheet based on 40% ethylene glycol solution fluid.
4. Please contact NEWIN sales representative if working condition not same as above standard design condition.
NEWIN Manufacturing Base

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
NEWIN FACTORY
Nestled in the vibrant Huizhou, Guangdong, our expansive manufacturing base spans an impressive 10,000 square meters, offering a state-of-the-art environment for innovation and production excellence.

ISO CERTIFICATION
Boasting prestigious ISO certifications, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin exemplifies a commitment to superior quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Cutting-edge Closed Type Cooling Tower Series engineered for optimal performance.
· NSH/ NST Highly efficient Open Type Cooling Tower Series designed for diversified applications.
· NTG Robust Industrial Type Cooling Tower Series tailored for demanding environments.
· NECN/NECH Sophisticated Evaporative Condenser systems that deliver superior cooling efficiency.
· NWFL Innovative Dry Air Cooler solutions offering high-capacity, energy-efficient performance.

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
NEWIN provides a comprehensive inventory of premium cooling tower accessories, catering to maintenance and replacement demands across a variety of cooling tower sizes and types. Reach out to us to tailor the precise cooling tower accessories you require.

CONTAIN:
· Fan drive system components including fan, fan stack, reducer, motor, and shaft, expertly crafted to enhance functionality.
· Water distribution elements like nozzles and drift eliminators, designed for optimal fluid management.
· Heat exchange components such as PVC infills and cooling coils, ensuring efficient thermal transfer.
· Additional accessories including air inlet louvers and valves, meticulously engineered for seamless integration.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Experience seamless transit with our expertly coordinated shipping solutions, ensuring your equipment arrives on time and in pristine condition.

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
Closed Type Cooling Towers Shipment: Discover the assurance of secure and efficient delivery, with our meticulous handling process safeguarding your valuable assets throughout their journey.
High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
Technical Strength& Standards

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs
High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

Certifications

High Capacity Hybrid Cooling Tower for Extreme Cooling NeedsHigh Capacity Hybrid Cooling Tower for Extreme Cooling NeedsHigh Capacity Hybrid Cooling Tower for Extreme Cooling NeedsHigh Capacity Hybrid Cooling Tower for Extreme Cooling Needs

High Capacity Hybrid Cooling Tower for Extreme Cooling Needs

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More