Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing

Product Details
Customization: Available
Cooling Method: Cross Flow, Cooling Tower
Certification: ISO, CE, ISO, CE, SGS
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
  • Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
  • Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
  • Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
  • Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
  • Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NAL Series
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Ordinary
Material
PVC
Application Fields
Cross Flow Cooling Tower
Model--Lah
PVC
Size
65/70thicknessx Any Length X Any Width
Continuous Operation Tempperature
50 Degree Centigrade
Max.Applicationtemp. (Short Term)
60 Degree Centigrade
Color
Black
Corrugation Height
18 mm
Thickness
65/70mm
Application
Cross Flow Square Cooling Tower
Transport Package
20/40/40hq Container with Loose Packing
Specification
65/70mm thickness
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

PVC Material Cooling Tower Fill Nal Air Inlet Louver

NAL series Newin NAL series air inlet louver icrafted with high-strength PVC sheets and securely bonded, the Newin air inlet louver is designed for ultimate durability. Choose between a robust galvanized steel or a sleek stainless steel frame, providing versatility to meet your specific needs. The innovative honeycomb inlet grille ensures optimized airflow into the cooling tower, efficiently filtering out impurities and preventing troublesome water splash. This design mitigates risks of icing, water damage, and unnecessary water loss, safeguarding your system with superior performance.

Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing

 
 
Features

Features

· Meticulously engineered to prevent debris from entering, ensuring long-lasting efficiency.
· Skillfully designed to prevent the splash of water droplets, maintaining optimal performance and cleanliness.
· Expert crafting restricts sunlight entry, effectively impeding algae growth to maintain a pristine environment within the cooling tower.
· Innovatively constructed to significantly reduce noise emissions from the tower, enhancing operational tranquility.
· Engineered to achieve an impressively low pressure drop, promoting efficient airflow and energy savings.
· Designed for effortless installation and simplified access, ensuring ease of cleaning and maintenance.
· Versatile in application, this product excels in new installations and retrofits alike, serving as a reliable air inlet for a multitude of systems.
Whether it's package or field-erected counter flow and straight-sided cross flow towers, fresh air make-up systems, or air pollution control scrubbers, its adaptability is unmatched.

 
Parameter

Properties
With an array of customizable features tailored to your specific needs in our NAL air inlet louver, including precise specifications on length, width, materials, and thickness, we invite you to communicate your detailed requirements. This ensures the delivery of perfectly tailored solutions and accurate proposals. At Newin, we pride ourselves on meeting all customer needs. Additionally, our fill media can be crafted in flame-retardant or anti-bacterial variants upon request, ensuring safety and hygiene.

Module Length (Max)  mm 2440
Module Width (Max)  mm 600
Module Thickness  mm 65
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing
Newin is dedicated to providing comprehensive support with our detailed structure and installation drawings, as well as jobsite storage recommendations. Accompanied by a quality control report, these resources are delivered with the shipment to ensure our clients receive their materials with confidence. We also offer OEM services and special mold designs tailored to your unique requirements upon request.Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing

Application

Application & Usage

The Newin EVL air inlet louver is expressly designed for counter flow cooling towers. It undergoes rigorous SGS testing in accordance with ASTM Standards, ensuring the highest quality of infill that significantly boosts the efficiency of your cooling tower. Simply provide us with your tower model or size, and we will precisely estimate the necessary air inlet louver size for seamless replacement.
Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing


Applicable Commercial Standards
The sheet materials adhere meticulously to the SGS testing protocols aligned with ASTM standards. Whether you require testing of individual properties or the entire range, we can accommodate your requests, ensuring your product meets these stringent standards.

Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Air Inlet Louver Replacement
Please provide the measurements below for your maintenance cooling tower or repair projects. When you demand unparalleled quality and reliability, trust Newin for site visits or maintenance services. Our solutions are expertly engineered to fit your cooling tower fills and components with precision and excellence. Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing

NEWIN Manufacturing Base

Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements.

ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model embodies the cutting-edge of cooling tower technology.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.

Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
 
Packaging & Shipping

Open type cooling towers shipment: Discover unparalleled security and precision with our expertly coordinated transportation service for open-type cooling towers. Each tower is thoughtfully encased with premium-grade materials and innovative packing techniques, ensuring they reach your destination in pristine condition. Our unwavering dedication to safeguarding your investment translates into comprehensive protection against potential transit risks. Enjoy the convenience of our streamlined logistics and punctual delivery, meticulously designed to activate your cooling solutions without delay.

Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
Closed type cooling towers shipment: Revel in the assurance of our exceptional packaging solutions tailored for closed-type cooling towers. Every unit is encapsulated with utmost care and resilience to withstand rigorous transit conditions, guaranteeing their pristine arrival and immediate readiness for deployment. Our unyielding commitment to excellence and swift delivery allows you to effortlessly integrate our state-of-the-art cooling innovations into your operations, freeing you from concerns over logistics.
Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
Technical Strength& Standards

Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing
Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing

Certifications

Durable Air Inlet Louver for Optimal Wet and Dry Air MixingDurable Air Inlet Louver for Optimal Wet and Dry Air MixingDurable Air Inlet Louver for Optimal Wet and Dry Air MixingDurable Air Inlet Louver for Optimal Wet and Dry Air Mixing

Durable Air Inlet Louver for Optimal Wet and Dry Air Mixing








 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More