Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)

Product Details
Customization: Available
Cooling Method: Cross Flow
Ventilation Mode: Mixing Ventilation
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
  • Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
  • Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
  • Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
  • Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
  • Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
Find Similar Products
  • Overview
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NST series
Material
FRP
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
ISO
Condition
New
Nominal Flow
900 M3/H
Motor Power
5.5*6kw
Fan Diameter
2100mm
Net Weight
6730kg
Running Weight
19930kg
Water Pressure
42 Kpa
Transport Package
20/40/40hq Container with Loose Packing
Specification
15600*3800*3700mm
Trademark
NEWIN
Origin
China
HS Code
841950090
Production Capacity
15000 Sets / Year

Product Description

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)

Open Type Cross Flow Cooling Tower NST-S series Stainless Steel Cooling Tower


Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
NST-S series Full-Steel Cross Flow Square Cooling Tower is available in capacity for single cell from 100 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements.This cooling tower is highly used in heating, ventilation, air-conditioning, and light to medium processing applications.

Features

- Adopts Cross flow open-loop technology, enough air inlet from both side, even spray water distribution, efficient heat exchanger pvc layer.
- Full-Steel Modular design, adopts Zinc-Aluminum/Stainless steel 304 /316L material, high strength, good rigidity, nice appearance.
- Resistant to acid and alkali, effectively eliminate the oxidation on the surface of the galvanized/Stainless steel 304 /316L.



Cross Flow Cooling Tower Structure

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)

Components Instruction


CASING AND BASIN
Using 304/316 stainless steel materials plate, high strength , high corrosion resistant and light weight.

FAN & DRIVING SYSTEM
Adopting low speed, big chord length, and width of blade fan, with stable wind speed, low noise, and high efficiency, etc. Enough airflow can easily get at low rotating speed of the fan, what's more, blade angle can be adjusted according to different climate conditions. Used aluminum alloy fan blades, solid fan or hollow type available for different customers' request.
Using motor with IP55 protection grade, F class insulation grade, smooth operation, low failure rate. Options: Siemens, ABB

DISTRIBUTION SYSTEM
Using the unique overflow device to realize smooth and even water distribution under different system load, the device completely eliminates the drift loss of coolig tower. Hot water basin cover avoids water pollution by foreign objects falling into hot basin. Meantime, it avoids direct sunlight and inhabit growth of algae.

FILL PACKING
Used high quality & improved performance PVC with good material, it is high cooling efficiency and anti-corrosive & UL V-0. Brand new PVC materials, integrated eliminators and louvers. The infills are hanging type, environmental friendly and  big coefficient of heat transfer, good hydrophilicity. Small wind resistance, high ventilation performance. Special material for option if high entering water temperature.

FRAME STRUCTURE AND FASTENERS
Leading structure design and high-quality materials to make frame structure and fasteners, the standard configuration of structure and fasteners is superior hot-dip galvanized steel, good anti-corrosion, design lifespan is more than 15 years. Stainless steel or F.R.P frame structure available for poor water soltion, and SUS304 or SUS316L for fasteners.  


Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)


Technical Specification of NST-S/SS Series Cooling Tower
 
Model Cooling Capacity
(RT)
Motor
kw
Fan Diameter
mm
Dimension (mm) Water Inlet
DN
Water Outlet
DN
Weight (kg)
H W L Dry Wet
NST-S/SS-19-A16-3A12-C1 100 3(A) 1600 3680 3800 1900 100*2 125 1250 2650
NST-S/SS-22-B16-3A12-C1 125 4(B) 1600 380 3800 2200 125*2 150 1350 2750
NST-S/SS-22-B18-3A14-C1 150 4(B) 1800 4080 4010 2200 125*2 150 1450 2950
NST-S/SS-26-C22-3A14-C1 175 5.5(C) 2200 4080 4420 2600 125*2 200 1550 3250
NST-S/SS-26-C22-3A15-C1 200 5.5(C) 2200 4280 4420 2600 150*2 200 1720 3530
NST-S/SS-26-D22-3A16-C1 225 7.5(D) 2200 4480 4420 2600 150*2 200 1820 4170
NST-S/SS-30-D24-3A16-C1 250 7.5(D) 2400 4680 4620 3000 150*2 250 2280 4700
NST-S/SS-30-D24-4A14-C1 300 7.5(D) 2400 4280 5230 3000 150*2 250 2620 5470
NST-S/SS-30-E24-4A16-C1 350 11(E) 2400 4680 5230 3000 150*2 250 2750 5700
NST-S/SS-33-E28-4B18-C1 400 11(E) 2800 5130 5640 3300 150*4 300 3050 6600
NST-S/SS-33-F28-4B20-C1 450 15(F) 2800 5500 5640 3300 150*4 300 3450 7000
NST-S/SS-38-F28-4B20-C1 500 15(F) 2800 5500 5640 3800 150*4 300 3750 7800
NST-S/SS-38-F34-4B20-C1 550 15(F) 3400 5630 6240 3800 150*4 350 4250 8600
NST-S/SS-46-G34-4B20-C1 600 18.5(G) 3400 5630 6240 4600 150*4 350 4850 10200
NST-S/SS-46-G36-4B22-C1 700 18.5(G) 3600 6030 6450 4600 150*4 350 5250 14500
NST-S/SS-51-I36-4B22-C1 800 30(I) 3600 6080 6450 5100 200*4 400 5650 15500
NST-S/SS-53-I42-4B24-C1 900 30(I) 4200 6530 7060 5300 200*4 400 6450 17800
NST-S/SS-53-J42-4B26-C1 1000 37(J) 4200 6930 7440 5300 200*4 400 7150 19500


Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
OPTIONS

Revolutionary Permanent Magnetic Direct-Driven Fan System
Innovative Energy Saving Design

> Experience superior variable frequency control that ensures low-speed operation while achieving high efficiency and a remarkable high power factor.
> Benefit from a direct-driven fan designed to eliminate transmission losses and maintenance requirements, providing a hassle-free experience.
> Achieve unparalleled energy efficiency with a rating up to IE5, delivering notable power savings and impressive energy conservation.
Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
NWN-Armour Advanced Corrosion Resistant Technology
Resilient Corrosion Resistant Design

Our galvanized steel panel, enhanced with the continuously upgraded NWN-Armour anti-corrosion coating, offers corrosion resistance comparable to Stainless Steel. This makes it an economically smart choice and a cost-effective alternative to Stainless Steel materials.

Additional Accessories to Enhance Functionality
Include premium features like a PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction to tailor your cooling tower to your specific requirements.
 
NEWIN Manufacturing Base

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
NEWIN FACTORY
Discover the expansive manufacturing base of NEWIN, nestled in the industrial heartland of Huizhou, Guangdong. This state-of-the-art facility spans a sprawling 10,000 square meters, dedicated to excellence in every facet of production.

ISO CERTIFICATION
NEWIN proudly upholds the highest standards with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, ensuring impeccable quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Revolutionary Closed Type Cooling Tower Series, engineered for optimal efficiency and performance.
· NSH/ NST Innovative Open Type Cooling Tower Series, designed for versatility and reliability in diverse applications.
· NTG Robust Industrial Type Cooling Tower Series, crafted for heavy-duty cooling solutions.
· NECN/NECH Advanced Evaporative Condenser, for superior thermal management and energy efficiency.
· NWFL Efficient Dry Air Cooler, offering reliable performance in varied cooling requirements.

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
At NEWIN, we manufacture and maintain an extensive inventory of essential cooling tower accessories, ready to meet the diverse maintenance and replacement needs for any size or type of cooling tower. Reach out to us for customized solutions tailored to your specific requirements.

CONTAIN:
· Comprehensive Fan Drive System (including fan, fan stack, reducer, motor, shaft, etc.)
· Advanced Water Distribution Components (featuring nozzles, drift eliminator, etc.)
· Superior Heat Exchange Elements (such as PVC infills, cooling coil, etc.)
· Additional Accessories (including air inlet louver, valve, etc.)
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Ensuring the safe and secure delivery of our remarkable open type cooling towers, we meticulously package each unit to withstand the rigors of transport. Our commitment to excellence extends beyond manufacturing to include reliable shipping solutions, ensuring your equipment arrives in pristine condition.

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
Closed Type Cooling Towers Shipment: We take immense pride in our thoughtful shipping process for closed type cooling towers. Each unit is packaged with precision and care, guaranteeing that it reaches its destination intact and ready for seamless integration into your operations. Trust in our dedicated approach to deliver not just a product, but a promise of quality.
Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
Technical Strength& Standards

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)
Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)

Certifications

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)

Newin Large Capacity Cross Flow Cooling Tower (NST-900/M)



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier