Durable PVC Cooling Tower Air Intake Louver for Efficient Performance

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE, ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
  • Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
  • Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
  • Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
  • Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
  • Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
EVL
Condition
New
Material
PVC/PP
Colour
White,Black
Usage
Cooling Tower
Transport Package
Woodencase 20gp/40gp Container
Trademark
newin
Origin
China
HS Code
8419909000
Production Capacity
500000/Year

Product Description

EVL Cooling Tower Air Inlet Louver
Introducing the Newin EVL Series Air Inlet Louver, expertly crafted from high-strength PVC sheet and meticulously bonded to ensure durability. The robust surrounding frame offers versatility with options in galvanized steel or stainless steel, catering to specific needs. Featuring an advanced honeycomb inlet grille design, this innovative louver optimizes airflow into the cooling tower. It is engineered to efficiently filter out impurities and prevent water splash, thereby reducing risks of icing, water damage, and unnecessary water loss, ensuring a seamless and effective performance.

Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
Features

Features

- Enhances airflow efficiently into the cooling tower, ensuring optimal performance.
- Prevents unwanted debris from entering, safeguarding the internal components.
- Minimizes the splash of water droplets, maintaining a clean and professional environment.
- Limits sunlight ingress into the tower, effectively reducing algae growth and prolonging efficiency.
- Significantly diminishes operational noise, creating a more pleasant and quieter workspace.
- Delivers exceptionally low pressure drop results for superior energy efficiency.
- Facilitates easy installation, featuring straightforward access for cleaning and maintenance to ensure longevity.
- Versatile in its application, the louver is ideal for both new installations and retrofits, including efficient air inlets for both package
and field-erected counter flow and straight-sided cross flow towers. It's also perfect for fresh air make-up systems, air pollution control scrubbers, and VOC strippers, providing a comprehensive solution for various industrial needs.

 
Parameter

Properties
For any specific requirements regarding the EVL air inlet louver, such as desired length, width, materials, or thickness, we encourage you to share your detailed needs with us. This ensures you receive the most accurate solutions and offers. At Newin, we pride ourselves on meeting all customer specifications. Additionally, we offer fill media with optional flame retardant or anti-bacterial properties, available upon request.

Module Length (Max)  mm 2440
Module Width (Max)  mm 800
Module Thickness  mm 80
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.5
Sheet Thickness - After  Forming  mm 0.4
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing
Newin provides comprehensive structure and installation drawing guidance, backed with practical jobsite storage advice and a quality control report accompanying every shipment. This ensures customers have all necessary information upon receiving materials. Moreover, OEM or special mold design options are also available upon request, catering to unique client needs and preferences.
Durable PVC Cooling Tower Air Intake Louver for Efficient Performance

Application

Application & Usage
The Newin EVL air inlet louver is expertly designed for maximum compatibility with counter flow cooling towers. Equipped with rigorous SGS testing under ASTM Standards, this louver ensures the highest quality infill, enhancing the efficiency of your cooling tower. Simply provide us with the model or size of your tower, and we'll precisely gauge the ideal air inlet louver size for seamless replacement.Durable PVC Cooling Tower Air Intake Louver for Efficient Performance

Applicable Commercial Standards
Our sheet materials are meticulously crafted to adhere to the SGS test requirements, conforming to ASTM standards. Upon request, we offer comprehensive testing of each property or all properties, ensuring our products meet your highest expectations.

Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.
 


Filed Data for Cross Flow Film Fill Replacement
To meet your maintenance or repair demands, Newin invites you to fill in the measurements below for your cooling tower projects. We pledge supreme quality and reliability, offering site visits and maintenance services tailored to fit your cooling tower's fills or components. Trust Newin for engineered precision and dependable performance.
Durable PVC Cooling Tower Air Intake Louver for Efficient Performance

NEWIN Manufacturing Base

Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
NEWIN FACTORY
Our state-of-the-art manufacturing base, nestled in the vibrant and industrious region of Huizhou, Guangdong, proudly extends over an impressive 10,000 square meters. This expansive facility serves as a robust foundation for pioneering innovation and achieving outstanding excellence in our field.

ISO CERTIFICATION
Proudly adhering to the industry's highest standards, our prestigious certifications include ISO9001:2015 for exceptional Quality Management and ISO14001:2015 for our unwavering commitment to leading Environmental Management practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Explore our state-of-the-art Closed Type Cooling Tower Series, expertly engineered to deliver precision, maximum efficiency, and superior performance.
· NSH/ NST Introducing our meticulously designed Open Type Cooling Tower Series, crafted to ensure optimal performance and unwavering reliability every time.
· NTG Discover our Industrial Type Cooling Tower Series, skillfully crafted to meet the rigorous and demanding needs of industrial applications.
· NECN/NECH Our exceptional Evaporative Condenser guarantees superior cooling efficiency and outstanding performance, setting new benchmarks in the industry.
· NWFL Our Dry Air Cooler series stands as a beacon of cutting-edge design and unparalleled energy efficiency, setting new standards in cooling technology.

Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
NEWIN is your trusted partner in providing a comprehensive range of cooling tower accessories. We not only stock but also manufacture components to support maintenance and replacements for virtually any size or type. Reach out to us to tailor the perfect accessories that precisely meet your specific requirements.

CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (nozzles/ drift eliminator etc.)
· Heat exchange (PVC infills/ cooling coil etc.)
· Other accessories (air inlet louver/ valve etc.)
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Dive into a realm of unparalleled delivery excellence with our open type cooling towers. Crafted to exceed the highest safety and reliability standards, these towers ensure supreme performance with ease. Our skilled team orchestrates an impeccable logistics experience, guaranteeing that your order arrives swiftly at your specified location, without any complications. Trust us to elevate your delivery expectations with exemplary service that defines new heights of perfection.

Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
Closed Type Cooling Towers Shipment: Our closed type cooling towers are meticulously encased with precision and care, ensuring they arrive at your location in immaculate condition. We promise a secure and timely journey, maintaining the superior performance and integrity of our top-tier cooling systems, from our facility to your doorstep. Rely on our extensive expertise for a seamless, stress-free shipping experience, instilling confidence and peace of mind at every step.
Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
Durable PVC Cooling Tower Air Intake Louver for Efficient Performance
Technical Strength& Standards

Durable PVC Cooling Tower Air Intake Louver for Efficient Performance

Certifications

 

Durable PVC Cooling Tower Air Intake Louver for Efficient PerformanceDurable PVC Cooling Tower Air Intake Louver for Efficient Performance




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More