Injection molding is a method for the production of industrial products. The products are usually injection molded with rubber and plastic. Injection molding can also be divided into injection molding and die casting. Injection molding machines (referred to as injection machines or injection molding machines) are thermoplastic or thermosetting materials. The main molding equipment for plastic products of various shapes is made by using plastic molding die. Injection molding is realized by injection molding machine and mold. The temperature of hot water generated by the cooling system of injection molding equipment is relatively higher than that of other industries (such as cast iron). Low, the cooling tower cooling capacity is relatively low. The cooling tower is a device that uses water as a circulating coolant to absorb heat from a system and discharge it into the atmosphere to lower the water temperature. The cold is cooled by the contact of water and air. The heat exchange generates steam, and the steam volatilizes the heat to achieve the principles of evaporative heat dissipation, convection heat transfer and radiation heat transfer to dissipate the waste heat generated in the industrial or refrigeration air-conditioning to reduce the water temperature, so as to ensure the normal operation of the system. The device is generally barrel or bottle shaped.
NRT series cooling towers are mainly used in the central industrial system. Please refer to the information of this model below
NRT series cooling towers are high efficiency that designed by our veteran engineers on basis of different environment and climate around the world, with reference to China standard "medium and small sizes glass fiber reinforced plastics cooling tower GB7190.0-2008", which fit with various environmental changes in different countries, better solved the problem that environment changes affect the cooling effect of the cooling tower, which also guarantee the matched equipment run normally and save energy to the largest extent.
Features:
1. Frame
Designed by using chains structure, the frame is stable and with good rigidity. The load is evenly distributed among each foundation, which makes operation more smooth. All structure parts are processed by hot dip galvanized zinc and has excellent performance of anti-rust and anti-corrosion.
2. Glass fiber reinforced plastics
Using good quality surface sizing, UPR and glass fiber as raw materials, with standardized abrasive tools for production, glass fiber reinforced plastics surface is glossy, evenly colored, aging resistance, fastcolours and durable.
3. Motor
Using totally closed cooling tower's exclusive motor, protection level IP54, good sealing, which is suitable for running in damp and hot environment with low noise and long lifetime.
4. Fan
Using wide blade, raked space twisted, low rotate speed and aluminum alloy axial fan, which is low rotate speed, large air quantity, low noise in operation and good dynamic balance etc., its angle is adjustable, which suits customers' requirements on air quantity and noise etc. Aspects very well
5. Reducing gear
Reducer casing using imported bearings and triangle belt, which guarantee cooling tower's reducing gear run smoothly with low noise and makes tower's lifetime longer.
6. In fill
Made of good P. V. C plain film that is processed through hot water heating and compression, which makes cooling tower's reducing gear run smoothly with low noise and lifetime longer.
7. Sprinkler head
Using aluminum alloy, imported bearings inside, high precision installation, close fit, smooth running, long lifetime.
8. Water basin
Designed on basis of large water reservation and high water level, which avoids pump-out while starting and guarantees equipment run normally.
Parts |
Material |
Remark |
Water Basin |
F.R.P |
Water-resistance resin and high quality fiberglass mat |
Casing |
F.R.P |
Water-resistance resin and high quality fiberglass mat |
Motor |
Cast Iron |
Fully enclosed anti water type, other brand motors for optional |
Motor support |
Hot dip galvanized steel |
In accordance with BS EN ISO1461:1999 standard |
Fan |
A.B.S |
Aluminum alloy material for optional |
Infill |
P.V.C film |
For high temperature inlet water, UPVC and PP material for optional |
Air inlet screen |
P.V.C |
F.R.P for optional |
Sprinkler head |
A.B.S |
Aluminum alloy material for optional |
Sprinkler pipe |
P.V.C |
For high temperature inlet water, hot-dip galvanized steel for optional |
Bolts & Nuts |
Electroplated |
Stainless steel 304, 316 for optional |
Item |
Nominal
Flow
(m3/h) |
Dimension
(mm) |
Motor
(Kw) |
Fan
Diam.
(mm) |
Air Flow
(cmm) |
water
pressure
(Kpa) |
Weight
(kg) |
Model |
Diam.
Max. |
Height |
Net
weight |
Run.
Weight |
NRT-8 |
6.2 |
945 |
1380 |
0.18 |
525 |
70 |
13 |
42 |
180 |
NRT-10 |
7.8 |
945 |
1530 |
0.18 |
600 |
85 |
13 |
46 |
190 |
NRT-15 |
11.7 |
1195 |
1415 |
0.37 |
600 |
140 |
13 |
54 |
290 |
NRT-20 |
15.6 |
1195 |
1590 |
0.55 |
730 |
160 |
14 |
67 |
300 |
NRT-25 |
19.5 |
1400 |
1820 |
0.75 |
730 |
200 |
16 |
98 |
500 |
NRT-30 |
23.4 |
1650 |
1705 |
0.75 |
730 |
230 |
16 |
116 |
530 |
NRT-40 |
31.2 |
1650 |
1775 |
1.5 |
890 |
280 |
16 |
130 |
550 |
NRT-50 |
39.2 |
1830 |
1835 |
1.5 |
890 |
330 |
17 |
190 |
975 |
NRT-60 |
46.8 |
2145 |
1955 |
1.5 |
1150 |
420 |
17 |
240 |
1250 |
NRT-80 |
62.6 |
2145 |
2035 |
1.5 |
1150 |
450 |
18 |
260 |
1280 |
NRT-100 |
78.1 |
2900 |
2370 |
2.2 |
1410 |
700 |
21 |
500 |
1690 |
NRT-125 |
97.5 |
2900 |
2555 |
2.2 |
1410 |
830 |
23 |
540 |
1640 |
NRT-150 |
117 |
2900 |
2555 |
2.2 |
1410 |
950 |
23 |
580 |
1680 |
NRT-175 |
136.8 |
3310 |
3165 |
4 |
1750 |
1150 |
30 |
860 |
1960 |
NRT-200 |
156.2 |
3310 |
3165 |
4 |
1750 |
1250 |
30 |
880 |
1980 |
NRT-225 |
175.5 |
4120 |
3580 |
5.5 |
2100 |
1500 |
33 |
1050 |
2270 |
NRT-250 |
195.1 |
4120 |
3580 |
5.5 |
2100 |
1750 |
33 |
1080 |
2800 |
NRT-300 |
234 |
4730 |
3680 |
7.5 |
2400 |
2000 |
34 |
1760 |
3930 |
NRT-350 |
273.2 |
4730 |
3680 |
7.5 |
2400 |
2200 |
34 |
1800 |
3790 |
NRT-400 |
312.1 |
5600 |
3840 |
11 |
2745 |
2400 |
36 |
2840 |
5740 |
NRT-500 |
392.4 |
5600 |
3840 |
15 |
2745 |
2600 |
36 |
2900 |
5800 |
NRT-600 |
468 |
6600 |
4470 |
15 |
3400 |
3750 |
42 |
3950 |
9350 |
NRT-700 |
547.2 |
6600 |
4470 |
18.5 |
3400 |
3750 |
42 |
4050 |
9450 |
NRT-800 |
626.4 |
7600 |
4720 |
22 |
3700 |
5000 |
45 |
4700 |
11900 |
NRT-1000 |
781.2 |
7600 |
4720 |
22 |
3700 |
5400 |
45 |
4900 |
12100 |
OPTIONS
Revolutionary Permanent Magnetic Direct-Driven Fan System
Innovative Energy Saving Design
> Experience superior variable frequency control that ensures low-speed operation while achieving high efficiency and a remarkable high power factor.
> Benefit from a direct-driven fan designed to eliminate transmission losses and maintenance requirements, providing a hassle-free experience.
> Achieve unparalleled energy efficiency with a rating up to IE5, delivering notable power savings and impressive energy conservation.
NWN-Armour Advanced Corrosion Resistant Technology
Resilient Corrosion Resistant Design
Our galvanized steel panel, enhanced with the continuously upgraded NWN-Armour anti-corrosion coating, offers corrosion resistance comparable to Stainless Steel. This makes it an economically smart choice and a cost-effective alternative to Stainless Steel materials.
Additional Accessories to Enhance Functionality
Include premium features like a PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction to tailor your cooling tower to your specific requirements.
NEWIN Manufacturing Base
NEWIN FACTORY
Discover the expansive manufacturing base of NEWIN, nestled in the industrial heartland of Huizhou, Guangdong. This state-of-the-art facility spans a sprawling 10,000 square meters, dedicated to excellence in every facet of production.
ISO CERTIFICATION
NEWIN proudly upholds the highest standards with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, ensuring impeccable quality and sustainable practices.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Revolutionary Closed Type Cooling Tower Series, engineered for optimal efficiency and performance.
·
NSH/ NST Innovative Open Type Cooling Tower Series, designed for versatility and reliability in diverse applications.
·
NTG Robust Industrial Type Cooling Tower Series, crafted for heavy-duty cooling solutions.
·
NECN/NECH Advanced Evaporative Condenser, for superior thermal management and energy efficiency.
·
NWFL Efficient Dry Air Cooler, offering reliable performance in varied cooling requirements.
At NEWIN, we manufacture and maintain an extensive inventory of essential cooling tower accessories, ready to meet the diverse maintenance and replacement needs for any size or type of cooling tower. Reach out to us for customized solutions tailored to your specific requirements.
CONTAIN:
· Comprehensive Fan Drive System (including fan, fan stack, reducer, motor, shaft, etc.)
· Advanced Water Distribution Components (featuring nozzles, drift eliminator, etc.)
· Superior Heat Exchange Elements (such as PVC infills, cooling coil, etc.)
· Additional Accessories (including air inlet louver, valve, etc.)
Packaging & Shipping
Open Type Cooling Towers Shipment: Ensuring the safe and secure delivery of our remarkable open type cooling towers, we meticulously package each unit to withstand the rigors of transport. Our commitment to excellence extends beyond manufacturing to include reliable shipping solutions, ensuring your equipment arrives in pristine condition.
Closed Type Cooling Towers Shipment: We take immense pride in our thoughtful shipping process for closed type cooling towers. Each unit is packaged with precision and care, guaranteeing that it reaches its destination intact and ready for seamless integration into your operations. Trust in our dedicated approach to deliver not just a product, but a promise of quality.
Technical Strength& Standards
Certifications