Introducing the NEWIN NWF Series: a state-of-the-art Mixed Flow Closed Type Cooling Tower. Experience a fusion of innovation and efficiency like never before.
NWF: The Pinnacle of Closed Cooling Tower Design. The NWF series closed cooling tower is a masterpiece of engineering, utilizing advanced, efficient composite flow cooling technology to ensure stable operation. This product is a testament to energy-saving and environmentally friendly design. As the spray water cools the heat exchange coil, it effortlessly transitions into the cold water basin via the PVC heat exchange layer. This clever design significantly reduces the tower's internal temperature while also minimizing noise from direct water spray, ensuring a quieter, more efficient cooling experience.
Product Description
High-Efficiency Mixed Flow Closed Circuit System
Operation
Experience unparalleled cooling efficiency with our advanced fluid medium technology. The medium requiring cooling seamlessly traverses the innovative serpentine coil heat exchanger, where a strategic external spray system diligently moistens the coil surface. This process enhances cooling efficacy as the cooled medium interacts with spray water via a partition wall heat exchanger, ensuring a closed loop for consistent cooling. Low-temperature dry air enters the tower laterally, engaging vertically with the spray water flow. This synergy forms a composite heat transfer, driven by robust fans. After optimal heat exchange, the high-temperature saturated air exits the tower, while the spray water undergoes an additional heat transfer through a sophisticated PVC heat exchange layer. Finally, it descends into a collection basin, expelling surplus heat with exceptional cooling efficiency.
Advantage
> The Mixed flow close-loop circulation system ensures media purity, significantly reduces maintenance costs, and conserves valuable water resources while delivering remarkable cooling performance.
> The harmonious blend of a stainless steel coil heat exchanger and a PVC heat exchange layer is both efficient and aesthetically pleasing. This pioneering design maximizes the heat transfer area, remarkably boosts heat exchange efficiency, and contributes to sound reduction.
> The innovative single-side air intake design significantly curtails noise emissions at the tower's rear, ensuring it is perfect for noise-sensitive environments.
> The product boasts a compact and space-conserving design, facilitating the integration of multiple cooling towers effortlessly.
Features
COOLING TOWER PARTS
1. Axial Flow Fan
Experience the pinnacle of performance with our aluminum alloy axial flow fan, engineered for low noise operation, stability, and unparalleled efficiency. The motor proudly features a superior protection grade of IP55 and an insulation grade of F, ensuring an elevated level of safety and reliability that stands the test of time.
2. External Spray System
Our innovative spray system efficiently distributes cool water over the heat exchange coil, keeping its surface consistently wetted for optimal cooling performance.
3. Stainless Steel Heat Exchange Coil
Crafted from premium stainless steel, these coils offer outstanding heat exchange efficiency and enhanced corrosion resistance. Their lightweight design contributes to a longer equipment lifespan and promotes environmental sustainability thanks to their recyclability.
4. MAH PVC Fill Film (PVC heat exchange layer)
Engineered for excellence, our PVC filler heat exchange layer integrates the filler, air inlet grille, and drift eliminator, ensuring consistent air intake and significantly reducing water drift loss. This optimal design guarantees superior heat transfer performance. The thoughtfully textured surface maximizes heat exchange area, enhancing overall efficiency. Adaptability is key, as the filler can be upgraded to high-temperature materials to suit your project's specific requirements.
5. MBD PVC Drift Eliminator
This precision-engineered drift eliminator, tailored for closed cooling towers, excels in effectively capturing airborne water droplets. It features minimal wind resistance and an outstanding capture rate of 99.99%, ensuring superior heat transfer performance.
6. Air Inlet Louver
Designed to perfection, it ensures the even intake of cool, dry air through the coil and PVC heat exchange layer, while effectively minimizing sun exposure and microbial growth.
7. Heavy-duty construction
Built with high-quality Z700 galvanized steel for frame and shell durability,our construction offers excellent corrosion resistance. For challenging environments, the optional SUS314/316 or NWN-Armour anti-corrosion coated steel delivers exceptional protection.
8. Access Door
Gain seamless entry to the tower's inner maintenance platform via the conveniently located access door.
The presence of an inspection platform inside the cooling tower greatly enhances ease of inspections and maintenance, ensuring smooth operations at all times.
Product Parameters

Design Conditions
NWF |
Dimension (mm) |
Weight (kg) |
Model |
L |
W |
H |
Dry |
Wet |
NWF-120-Z7-S |
2300 |
1910 |
2850 |
843 |
1935 |
NWF-180-Z7-S |
2300 |
1910 |
2930 |
883 |
2006 |
NWF-230-Z7-S |
2850 |
2110 |
2930 |
1140 |
2701 |
NWF-290-Z7-S |
3550 |
2110 |
2930 |
1377 |
3396 |
NWF-350-Z7-S |
4150 |
2110 |
2930 |
1601 |
4013 |
NWF-450-Z7-S |
4550 |
2250 |
3480 |
2055 |
4706 |
NWF-600-Z7-S |
4550 |
2250 |
3720 |
2197 |
4899 |
NWF-750-Z7-S |
5200 |
2250 |
4270 |
3201 |
6920 |
NWF-900-Z7-S |
5200 |
2250 |
4490 |
3549 |
7535 |
NWF-1000-Z7-S |
5200 |
2870 |
4490 |
4045 |
8589 |
NWF-1150-Z7-S |
5900 |
2870 |
4540 |
4536 |
9677 |
NWF-1450-Z7-S |
5900 |
3150 |
4690 |
5321 |
12230 |
NWF-1750-Z7-S |
6500 |
3150 |
4690 |
5943 |
13744 |
NWF-2300-Z7-S |
7500 |
3250 |
4900 |
6963 |
15214 |
Optional Various Additional Functions
Unleash the full potential of your Mixed Flow Cooling Tower with our exceptional range of optional enhancements. Choose from our Two-speed & VFD variable frequency motor for adaptable performance, a Vibration Cut-off Switch to ensure stability, an innovative Electronic descaler, and top-tier Water treatment equipment. Embrace our Anti-freeze automatic heating system for reliability in any climate, and opt for our Noise reduction upgrade to maintain a serene environment. Our External maintenance platform and guardrail offer unmatched safety during upkeep. Elevate your installation and maintenance efficiency with our practical boom and more, tailored to meet all operational needs.
Cost-effective Anti-Corrosion Solution
NWN-Armour Anti-corrosion Technology
Experience the pinnacle of protection with NWN-Armour Anti-corrosion Technology. Our specialized coating significantly enhances the durability and life span of our products, providing an exceptional barrier against corrosion. This state-of-the-art solution rivals the robustness of stainless steel, offering an economically savvy alternative that doesn't compromise on quality.el.
Application
Our Mixed Flow Cooling Tower with Powerful 7.5*3kw Fan Power is brilliantly designed for a wide array of applications, serving as a backbone in diverse sectors. It stands as an essential component in the Energy industry, offering robust support to ensure efficiency and reliability. Within the Pharmaceutical industry, it plays a critical role in maintaining precise environmental conditions necessary for the production of safe and effective drugs. In the realm of HVAC, it guarantees optimal climate control, enhancing comfort and functionality. The Chemical industry benefits from its efficient cooling capabilities, ensuring process stability and safety. In Machinery manufacturing and Metal processing, it provides essential cooling, enabling precision and effectiveness in operations. For Plastic products and Industrial cooling, it ensures seamless production processes. Finally, in Food processing, it is instrumental in preserving quality and safety throughout the production chain. Experience unparalleled versatility and efficiency with the cutting-edge cooling solutions of Newin (Guangdong) Machinery Co., Ltd.
NEWIN Manufacturing Base

NEWIN FACTORY
Our expansive manufacturing hub is strategically located in the vibrant city of Huizhou, Guangdong, sprawling across a substantial area of 10,000 square meters.
ISO CERTIFICATION
Proudly holding the prestigious ISO9001:2015 Quality Management System Certification, alongside the ISO14001:2015 Environmental Management System Certification, Newin stands as a beacon of quality and environmental responsibility.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
State-of-the-art Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Closed Type Cooling Tower Series
·
NSH/ NST Open Type Cooling Tower Series
·
NTG Industrial Type Cooling Tower Series
·
NECN/NECH Evaporative condenser
·
NWFL Dry Air Cooler
NEWIN is your go-to solution for all cooling tower accessories, ensuring that we meet your every maintenance and replacement requirement with a comprehensive stock for towers of all shapes and sizes. Reach out to us for tailored cooling tower accessory solutions that perfectly fit your needs.
CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (nozzles/ drift eliminator etc.)
· Heat exchange (PVC infills/ cooling coil etc.)
· Other accessories (air inlet louver/ valve etc.)
Packaging & Shipping
Shipment for Open Type Cooling Towers
Shipment for Closed Type Cooling Towers
Technical Strength& Standards


Certifications



