Drift Eliminator Internal for Superior Cooling Tower Performance

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Drift Eliminator Internal for Superior Cooling Tower Performance
  • Drift Eliminator Internal for Superior Cooling Tower Performance
  • Drift Eliminator Internal for Superior Cooling Tower Performance
  • Drift Eliminator Internal for Superior Cooling Tower Performance
  • Drift Eliminator Internal for Superior Cooling Tower Performance
  • Drift Eliminator Internal for Superior Cooling Tower Performance
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
BAD
Condition
New
Ventilation Mode
Mechanical Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Noise Level
Low
After-Sales Service
One Year
Warranty
One Year
Material
PVC
Tower Shape
Blade or Cellular
Application Fields
Cooling Tower
Transport Package
20/40/40hq Container with Loose Packing
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000

Product Description

Introducing the Newin Cellular Type Drift Eliminator, your ultimate solution for optimizing the efficiency and performance of your cooling towers. Specifically engineered with high-quality PVC, this Drift Eliminator is designed to drastically minimize water loss and ensure superior operational capability. Whether referred to as a PVC Drift Eliminator or simply a Drift Eliminator for Cooling Towers, this essential component by Newin guarantees reliability, durability, and unmatched performance in all cooling applications.
Drift Eliminator Internal for Superior Cooling Tower Performance
Product Description

BAD Newin BAExperience the pinnacle of cooling tower efficiency with our D cellular drift eliminator. Expertly engineered to eliminate the smallest water droplets entrained in exhaust air, it significantly reduces the risk of nuisance and health issues. The innovative design of our BAD series creates a complex airflow path, ensuring that water droplets are diverted, coalescing against the eliminator's side walls for efficient drainage back into the cooling tower's wet section, enhancing its performance and safety.

FEATURES

- Remarkably resistant to aging, with excellent water absorption capabilities.
- Engineered for minimal airflow resistance, offering unmatched strength.
- Effortless installation with a design that guarantees an extended service life.
- Versatile enough to replace traditional air inlet louvers.
Parameter

PROPERTIES

For those seeking the utmost in customization, Newin (Guangdong) Machinery Co., Ltd. presents the Drift Eliminator Internal for Superior Cooling Tower Performance. Catering to diverse demands in drift eliminators—be it variations in length, width, materials, or thickness—Newin assures a tailored solution that meets precise specifications. Simply share your detailed requirements with us to receive an accurate proposal and pricing. Additionally, we offer fill media in both flame-retardant and anti-bacterial formats, designed to elevate safety and hygiene, available upon request.
Module Length (Max)  mm 2440
Module Width  (Max)  mm 500
Module Height  mm 140
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.38
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


STRUCTURE & INSTALLATION DRAWING

Newin is committed to excellence, providing comprehensive support with structure and installation drawings, jobsite storage recommendations, and a thorough quality control report at the point of shipment. This ensures that all customers are well-informed upon receipt of their materials. For those with unique needs, OEM or specialized mold designs are also available upon request, showcasing our capacity for innovation and customization.

Drift Eliminator Internal for Superior Cooling Tower Performance

Application

APPLICATION & USAGE

The Newin BAD cellular drift eliminator is expertly crafted for the seamless replacement of BAC systems. A perfect fit for your cooling needs. Our drift eliminators are designed for optimal performance in cooling towers, rigorously tested to SGS standards within the ASTM framework. This ensures unparalleled quality of infill, enhancing the efficiency of your cooling tower. Provide us with the tower model or dimensions, and we will calculate the precise number of sheets needed for your replacement project.

Drift Eliminator Internal for Superior Cooling Tower Performance

APPLICABLE COMMERCIAL STANDARDS

The sheets material strictly adheres to rigorous SGS testing and complies with ASTM standards. Each property, as detailed below, can be tested upon request to guarantee the utmost quality and reliability of your products.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.


FIELD DATA FOR CELLULAR DRIFT ELIMINATOR REPLACEMENT

Provide the measurements data requested below for maintenance or repair projects involving cooling towers, where quality and reliability are paramount. Trust Newin for expert site visits or maintenance services, engineered specifically to meet your cooling tower's fill and component requirements.
Drift Eliminator Internal for Superior Cooling Tower Performance

NEWIN Manufacturing Base

Drift Eliminator Internal for Superior Cooling Tower Performance
NEWIN FACTORY
Embark on a remarkable journey to our cutting-edge manufacturing base, strategically situated in the vibrant industrial heart of Huizhou, Guangdong. Spanning an impressive 10,000 square meters, this facility stands as a beacon of innovation, extraordinary excellence, and remarkable technological advancements.

ISO CERTIFICATION
We proudly highlight our steadfast dedication to unparalleled quality and environmental responsibility with our esteemed ISO certifications: ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, setting the standard for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Drift Eliminator Internal for Superior Cooling Tower Performance
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unparalleled efficiency and ground-breaking innovation with our Closed Type Cooling Tower Series, meticulously engineered to deliver superior performance and unmatched reliability, representing the pinnacle of cooling tower technology.
· NSH/ NST Discover the unwavering reliability of our Open Type Cooling Tower Series, expertly crafted for optimal operation and robust performance, setting industry standards and consistently exceeding expectations for enduring excellence.
· NTG Explore the extraordinary capabilities of our Industrial Type Cooling Tower Series, specifically engineered to tackle heavy-duty and demanding applications, ensuring resilience and power at every juncture.
· NECN/NECH Seamlessly merge cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new benchmarks in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative potential of advanced technology with our Dry Air Cooler, expertly engineered for superior airflow and maximum efficiency, optimizing every aspect of cooling for unmatched results.

Drift Eliminator Internal for Superior Cooling Tower Performance
NEWIN stands as your trusted ally in premier cooling tower solutions, offering a comprehensive range of accessories to meet your maintenance and replacement demands. Tailor your choice to fit an extensive array of cooling tower sizes and types. Reach out to us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Our meticulously engineered open-type cooling towers are expertly packaged, guaranteeing they reach you in immaculate condition. We prioritize the utmost safety and security, employing premium materials and strategic packing techniques to provide an impregnable shield against any potential transit damages. Revel in seamless logistics and prompt delivery, ensuring that your cooling solutions become operational without delay for maximum efficiency and performance.

Drift Eliminator Internal for Superior Cooling Tower Performance
Closed type cooling towers shipment: Experience peace of mind with our robust packaging solutions for closed-type cooling towers. Each unit is meticulously encased to endure the rigors of transport, ensuring arrival at your site in pristine condition and ready to deliver top-tier performance. Our steadfast dedication to quality control and punctual shipping empowers you to concentrate on what truly matters - harnessing our cutting-edge cooling technology to enhance your applications and achieve unparalleled outcomes.
Drift Eliminator Internal for Superior Cooling Tower Performance
Drift Eliminator Internal for Superior Cooling Tower Performance
Technical Strength& Standards

Drift Eliminator Internal for Superior Cooling Tower Performance
Drift Eliminator Internal for Superior Cooling Tower Performance

Certifications

Drift Eliminator Internal for Superior Cooling Tower PerformanceDrift Eliminator Internal for Superior Cooling Tower PerformanceDrift Eliminator Internal for Superior Cooling Tower PerformanceDrift Eliminator Internal for Superior Cooling Tower Performance

Drift Eliminator Internal for Superior Cooling Tower Performance


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More