NWF Series Mixed Flow Evaporative Fluid Coolers/Closed Cooling Tower
NWF This series of closed cooling towers integrates cutting-edge composite flow cooling technology to ensure stable operation while promoting energy efficiency and environmental sustainability. After the spray water cools the heat exchange coil, it flows into the cold water basin via a PVC heat exchange layer, which significantly lowers the tower's internal temperature and minimizes noise typically generated by water falling directly into the basin.
Unparalleled High-Efficiency Mixed Flow Closed Circuit System
Seamless Operation
The fluid medium that requires cooling traverses a highly efficient serpentine coil heat exchanger. A perpetual external spray system keeps the coil surface wet, facilitating uninterrupted cooling. This allows the cooled medium to transfer heat with the spray water through a partition wall heat exchanger, establishing a closed loop for optimal cooling. Fresh, low-temperature dry air enters the tower laterally and crosses vertically with the spray water's flow, creating a composite heat transfer driven by powerful fans. Post heat exchange, the high-temperature saturated air exits the tower as the spray water undergoes a secondary heat transfer within a PVC heat exchange layer before settling into a water collection basin, effectively enhancing cooling efficiency to new heights.
Distinctive Advantages
> The Innovative Mixed Flow Closed-Loop Circulation System ensures the purity of the media, substantially reduces maintenance costs, and conserves valuable water resources, while ensuring exceptional cooling performance.
> The sophisticated combination of a stainless steel coil heat exchanger and a PVC heat exchange layer not only offers exceptional efficiency but also exudes elegance. This forward-thinking design maximizes heat transfer areas, boosts heat exchange efficiency, and even helps to reduce noise pollution.
> The ingenious single-side air intake design effectively reduces noise emissions at the rear of the tower, rendering it perfectly suited for noise-sensitive environments.
> The product boasts a compact and space-efficient design,enabling seamless integration of multiple cooling towers.
Features
COOLING TOWER PARTS
1. Axial Flow Fan
The aluminum alloy axial flow fan operates with low noise, stability, and efficiency. The motor is equipped with a protection grade of IP55 and an insulation grade of F, ensuring heightened safety and reliability.
2. External Spray System
Spray cool water into heat exchange coil,continuously wets the surface of the coil for cooling.
3. Stainless Steel Heat Exchange Coil
Stainless steel coils exhibit superior heat exchange efficiency, enhanced corrosion resistance, light weight, prolonged equipment lifespan, and are environmentally sustainable due to their recyclability.
4. MAH PVC Fill Film ( PVC heat exchange layer)
The PVC filler heat exchange layer utilizes an integrated design of filler, air inlet grille, and drift eliminator to guarantee consistent air intake, significantly minimize water drift loss, and ensure optimal heat transfer performance. Furthermore, the unique surface texture provides ample heat exchange surface area, thereby enhancing overall efficiency. The filler could be upgraded to high-temperature materials to align with the specific working conditions of the project.
5. MBD PVC Drift Eliminator
The exclusive drift eliminatordesigned for closed cooling towers is adept at efficiently extracting airborne water droplets, boasting minimal wind resistance and an impressive capture rate of 99.99%, thus guaranteeing optimal heat transfer performance.
6. Air Inlet Louver
Ensure cool dry air evenly sucked in and passed through the coil and the PVC heat exchange layer, Limiting sun exposure and microbial growth.
7. Heavy-duty construction
The high-quality Z700 galvanized steel frame and shell,offering corrosion resistance. For particularly harsh environments, the optional SUS314/316 or NWN-Armour anti-corrosion coated steel provides exceptional protection.
8. Access Door
Into the tower inner maintenance platform through the access door.
The presence of an inspection platform within the cooling tower enhances the convenience of conducting inspections and maintenance.
Product Parameters
Design Condition
NWF |
Dimension (mm) |
Weight (kg) |
Model |
L |
W |
H |
Dry |
Wet |
NWF-120-Z7-S |
2300 |
1910 |
2850 |
843 |
1935 |
NWF-180-Z7-S |
2300 |
1910 |
2930 |
883 |
2006 |
NWF-230-Z7-S |
2850 |
2110 |
2930 |
1140 |
2701 |
NWF-290-Z7-S |
3550 |
2110 |
2930 |
1377 |
3396 |
NWF-350-Z7-S |
4150 |
2110 |
2930 |
1601 |
4013 |
NWF-450-Z7-S |
4550 |
2250 |
3480 |
2055 |
4706 |
NWF-600-Z7-S |
4550 |
2250 |
3720 |
2197 |
4899 |
NWF-750-Z7-S |
5200 |
2250 |
4270 |
3201 |
6920 |
NWF-900-Z7-S |
5200 |
2250 |
4490 |
3549 |
7535 |
NWF-1000-Z7-S |
5200 |
2870 |
4490 |
4045 |
8589 |
NWF-1150-Z7-S |
5900 |
2870 |
4540 |
4536 |
9677 |
NWF-1450-Z7-S |
5900 |
3150 |
4690 |
5321 |
12230 |
NWF-1750-Z7-S |
6500 |
3150 |
4690 |
5943 |
13744 |
NWF-2300-Z7-S |
7500 |
3250 |
4900 |
6963 |
15214 |
Optional Various Additional Functions
Enhance the versatility of your system with our array of optional features: Two-speed and VFD variable frequency motor for seamless operation, vibration cut-off switch for enhanced safety, and an electronic descaler for optimum maintenance. Further options include state-of-the-art water treatment equipment, an anti-freeze automatic heating system to combat harsh climates, and noise reduction upgrades for a quieter environment. Secure workspaces with external maintenance platforms and guardrails, alongside convenient installation and maintenance boom, make operations smoother and safer.
Cost-effective Anti-Corrosion Solution
NWN-Armour Anti-corrosion Technology
Our products, fortified with the NWN-Armour anti-corrosion coating, display exceptional resistance against corrosion, closely rivaling the durability and performance of stainless steel. This technology offers a remarkably cost-effective alternative to traditional stainless steel solutions, ensuring robust protection and longevity.el.
The Closed Circuit Mixed Flow Cooling Tower from Newin (Guangdong) Machinery Co., Ltd. is meticulously engineered to cater to a diverse range of industrial sectors, ensuring optimal performance and efficiency. This versatile cooling solution finds its indispensable place in the Energy industry, providing reliable and efficient cooling for power generation systems. In the Pharmaceutical industry, it guarantees the necessary environmental conditions for sensitive processes and products. The HVAC sector benefits from its unmatched ability to maintain desired temperature levels, enhancing comfort and efficiency in various buildings. The Chemical industry relies on its robust design to support complex cooling requirements, ensuring safety and reliability. In Machinery manufacturing and Metal processing, it aids in maintaining the integrity of high-performance machinery and processed metals. Manufacturers of Plastic products utilize it to ensure consistent quality and precision in their outputs. As a cornerstone of Industrial cooling, it addresses the unique demands across various industrial applications, providing a tailored cooling experience. Lastly, in the Food processing industry, it ensures that products are processed under ideal temperature conditions, maintaining freshness and quality throughout production.
NEWIN Manufacturing Base
Explore the Efficient NEWIN FACTORY
Strategically located in Huizhou, Guangdong, our expansive manufacturing base spans over 10,000 square meters, poised to deliver excellence.
Prestigious ISO CERTIFICATION
Proudly holding the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification.
State-of-the-Art WORKSHOPS
Innovative Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Efficient Cooling Tower Assembly Workshop
RIGOROUS TESTING
Our Independent Testing LAB ensures top-quality output.
NEWIN COOLING TOWERS: A Spectrum of Excellence
·
NWN/ NWF/ NCFN Our renowned Closed Type Cooling Tower Series
·
NSH/ NST Innovative Open Type Cooling Tower Series
·
NTG Specialized Industrial Type Cooling Tower Series
·
NECN/NECH Efficient Evaporative Condenser
·
NWFL Advanced Dry Air Cooler
NEWIN offers a comprehensive range of cooling tower accessories, fully stocked to cater to maintenance and replacement needs, regardless of size or type. Contact us to tailor the perfect accessories for your cooling tower.
INCLUDES:
· Fan drive system (encompassing fan, fan stack, reducer, motor, shaft, and more)
· Water distribution components (including nozzles and drift eliminator)
· Heat exchange essentials (such as PVC infills and cooling coil)
· Additional accessories (such as air inlet louvers and valves)
Packaging & Shipping
Open Type Cooling Towers Shipment: Experience seamless logistics with our open type cooling towers. Every unit is expertly packed to withstand the journey, maintaining the superior performance and reliability that Newin (Guangdong) Machinery Co., Ltd. is renowned for. Our efficient shipping solutions guarantee timely delivery, keeping your projects on schedule.
Closed Type Cooling Towers Shipment: Our closed circuit mixed flow cooling towers are shipped with precision and attention to detail. Each cooling unit is secured and packaged to prevent any damage during transit, ensuring that you receive a product that lives up to Newin (Guangdong) Machinery Co., Ltd.'s high standards of quality and durability. Trust us for prompt and dependable delivery.
Technical Strength& Standards
Certifications