High-Capacity Dry Air Cooler for Effective Cooling Solutions

Product Details
Customization: Available
Ventilation Mode: Mechanical Ventilation
Material: Metal

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • High-Capacity Dry Air Cooler for Effective Cooling Solutions
  • High-Capacity Dry Air Cooler for Effective Cooling Solutions
  • High-Capacity Dry Air Cooler for Effective Cooling Solutions
  • High-Capacity Dry Air Cooler for Effective Cooling Solutions
  • High-Capacity Dry Air Cooler for Effective Cooling Solutions
  • High-Capacity Dry Air Cooler for Effective Cooling Solutions
Find Similar Products
  • Overview
  • Features
  • Working Principle
  • Parameter
  • Components& Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWFL-V
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Cooling Capacity
207~936kw
Transport Package
20/40/40hq Container
Specification
Multi-cells is available
Trademark
NEWIN
Origin
China
HS Code
84195000

Product Description

Unveiling the High-Capacity Dry Air Cooler: Your Gateway to Innovative Cooling Solutions


NWFL-V Introducing the NWFL-V series, an exceptional V-type dry air cooler meticulously crafted with an advanced Free Cooling System. This series is engineered to deliver efficient cooling prowess, making it an ideal choice for HVAC systems and various other facilities. Enjoy superior cooling performance with the added benefit of zero water consumption, setting it apart from traditional evaporative cooling systems. Elevate your cooling strategy with the NWFL-V, where innovation meets efficiency.

High-Capacity Dry Air Cooler for Effective Cooling Solutions
Features
· Ingeniously crafted with a V-type design integrated with a Free Cooling System,
Delivering superior cooling efficiency while ingeniously eliminating the need for water consumption.

· Incorporates optimal, high-efficiency components, such as the state-of-the-art EC motor,
Ensuring unparalleled system efficiency coupled with significant energy savings.

· Enhanced with substantial redundancy,
Thwarting any potential loss in thermal performance.

· Exhibits exceptional reliability and facilitates effortless maintenance.
High-Capacity Dry Air Cooler for Effective Cooling Solutions
 
Working Principle

High-Capacity Dry Air Cooler for Effective Cooling Solutions
When the NWFL-V adiabatic cooler is activated:
Our state-of-the-art NWFL-V adiabatic cooler utilizes a sophisticated EC fan system to draw in refreshingly cool, dry air. This air is then seamlessly channeled through the tower via a cutting-edge V-shaped finned tube heat exchanger. The ingenious V-shaped design maximizes the contact surface, dramatically accelerating the cooling process for both air and hot process fluid. This results in a substantial enhancement of heat exchange efficiency. Once the hot process fluid has undergone thorough partition wall heat exchange with the invigorating cool dry air, the hot saturated air is efficiently expelled from the tower. This remarkable process achieves superior Free Cooling-non-evaporative cooling-ensuring optimal performance and reliability.

Series Type Capacity 1. Fan Drive System 2. Heat Exchange System
NWFL-V V Range EC axial fans Finned coil
Maximum thermal performance 207~936kw Intelligent frequency conversion, 
more energy saving
Maximum heat transfer surface
Free cooling 
system
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption.
Application Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc.
Parameter
 
High-Capacity Dry Air Cooler for Effective Cooling Solutions
Model Cooling Capacity Total Dimension Fan Weight
L W H Nos of Fans Noise Level Power Shipping Operation
kw mm mm mm Nos dB(A) kw kg kg
NWFL-231-4D10-800V 200 2740 2050 2190 4 79.4 3.14  1187  1386 
NWFL-231-6D10-800V 250 2740 2050 2190 4 82.7 3.76  1332  1586 
NWFL-231-8D10-800V 290 2740 2050 2190 4 87.8 4.89  1477  1786 
NWFL-241-4D10-800V 255 2740 2050 2550 4 80 4.43  1329  1590 
NWFL-241-6D10-800V 315 2740 2050 2550 4 81.8 5.47  1522  1854 
NWFL-241-8D10-800V 360 2740 2050 2550 4 84.5 6.49  1714  2119 
NWFL-251-4D10-800V 310 2740 2050 2980 4 81.5 6.44  1493  1817 
NWFL-251-6D10-800V 400 2740 2050 2980 4 83 7.61  1732  2146 
NWFL-251-8D10-800V 450 2740 2050 2980 4 85 8.81  1971  2475 
NWFL-261-4D10-900V 375 2740 2250 3300 4 80.8 7.37  1675  2060 
NWFL-261-6D10-900V 470 2740 2250 3300 4 84.9 8.35  1961  2453 
NWFL-261-8D10-900V 535 2740 2250 3300 4 86.4 9.75  2247  2847 
Note:
1. Standard design working condition- Fluid in/out Temp. Difference: 5ºC.
2. Standard design ambient temperature- Temp. Approach: 15ºC.
3. Thermal design based on pure water.
4. Please contact NEWIN sales representative if the working condition is different from the above standard design condition.
Components& Options
High-Capacity Dry Air Cooler for Effective Cooling Solutions
· Built to Last with Heavy-Duty Construction

Crafted from galvanized steel panels enhanced with our proprietary NEWIN Armour anti-corrosion coating, this design delivers formidable resistance akin to stainless steel. This robust protection allows for high concentration cycles, significantly reducing water consumption. Furthermore, any coating damage can be effortlessly repaired, ensuring longevity and sustainable performance.
 
· Advanced V Type Finned Coil Heat Exchanger

This state-of-the-art finned coil heat exchanger features copper tubes and aluminum fins positioned for optimal heat transfer. The copper tubes are securely brazed to the coil headers and flared to the finned coil, maximizing thermal conduction and efficiency.
High-Capacity Dry Air Cooler for Effective Cooling Solutions
 
High-Capacity Dry Air Cooler for Effective Cooling Solutions
· High-Efficiency EC Axial Fan

- Our EC motor incorporates a straight-shaft drive with an IP55 protection grade and F insulation grade, expertly designed for continuous operation in extreme hot and humid environments. It provides exceptional smoothness, achieving remarkable energy efficiency that meets IE4 standards or higher.

- Integrated with durable tapered roller bearings, these fans deliver superior load-bearing capacity and boast an astounding service life of over 20,000 hours, ensuring unmatched performance and reliability.

- Through comprehensive static and dynamic testing, noise is meticulously minimized while upholding exceptional heat exchange capabilities. With integrated PFC technology, harmonics are kept to under 35%, ensuring the EC fan system sustains high static efficiency even at lower speeds.
 
· Cutting-Edge Adiabatic Intelligent Controls

- EC fans employ intelligent frequency conversion, adapting seamlessly to various on-site conditions, thereby enhancing energy savings.

- Optional dry operation mode is available when water usage is restricted, ensuring uninterrupted performance.
High-Capacity Dry Air Cooler for Effective Cooling Solutions

 

· Customization Options

- Enhance coil resistance capabilities for tougher applications.
- Implement coil freeze-up safeguards for operational security.
- Opt for a low noise upgrade to ensure quieter operations.
- Increase redundancy to bolster system reliability.
NEWIN Manufacturing Base

High-Capacity Dry Air Cooler for Effective Cooling Solutions
NEWIN FACTORY
Nestled in the vibrant heart of Huizhou, Guangdong, our expansive manufacturing base covers an impressive area of 10,000 square meters. This state-of-the-art facility stands as a beacon of innovation and excellence in production.

ISO CERTIFICATION
Proudly holding prestigious ISO certifications, such as ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin is a shining example of unwavering commitment to superior quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

High-Capacity Dry Air Cooler for Effective Cooling Solutions
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Discover our cutting-edge Closed Type Cooling Tower Series, expertly engineered for optimal performance and efficiency.
· NSH/ NST Explore our highly efficient Open Type Cooling Tower Series, meticulously designed for a wide range of applications, delivering exceptional performance.
· NTG Engage with our robust Industrial Type Cooling Tower Series, specially tailored for the most demanding environments, ensuring reliability and durability.
· NECN/NECH Experience our sophisticated Evaporative Condenser systems, engineered to deliver superior cooling efficiency and performance.
· NWFL Discover our innovative Dry Air Cooler solutions, offering high-capacity and energy-efficient performance, perfect for your unique cooling requirements.

High-Capacity Dry Air Cooler for Effective Cooling Solutions
NEWIN offers a comprehensive inventory of premium cooling tower accessories, catering to maintenance and replacement needs across various cooling tower sizes and types. Contact us to customize the precise cooling tower accessories for your specific needs.

CONTAIN:
· Expertly crafted fan drive system components, including fan, fan stack, reducer, motor, and shaft, designed to enhance functionality and performance.
· Optimally designed water distribution elements like nozzles and drift eliminators, ensuring superior fluid management.
· Efficient heat exchange components, such as PVC infills and cooling coils, ensuring effective thermal transfer capabilities.
· Additional meticulously engineered accessories, including air inlet louvers and valves, crafted for seamless integration and performance.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Experience seamless transit with our expertly coordinated shipping solutions, ensuring your equipment arrives on time and in pristine condition. Our commitment to excellence guarantees that every shipment is handled with the utmost care, delivering both reliability and satisfaction.

High-Capacity Dry Air Cooler for Effective Cooling Solutions
Closed Type Cooling Towers Shipment: Discover the assurance of secure and efficient delivery, with our meticulous handling process safeguarding your valuable assets throughout their journey. Trust in our precision-driven operations to provide you with peace of mind, knowing your equipment is protected from start to finish.
High-Capacity Dry Air Cooler for Effective Cooling Solutions
High-Capacity Dry Air Cooler for Effective Cooling Solutions
Technical Strength& Standards

High-Capacity Dry Air Cooler for Effective Cooling Solutions
High-Capacity Dry Air Cooler for Effective Cooling Solutions

Certifications

High-Capacity Dry Air Cooler for Effective Cooling SolutionsHigh-Capacity Dry Air Cooler for Effective Cooling SolutionsHigh-Capacity Dry Air Cooler for Effective Cooling SolutionsHigh-Capacity Dry Air Cooler for Effective Cooling Solutions

High-Capacity Dry Air Cooler for Effective Cooling Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More