Open Air Contact Drift Eliminator for Cooling Tower Systems

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Open Air Contact Drift Eliminator for Cooling Tower Systems
  • Open Air Contact Drift Eliminator for Cooling Tower Systems
  • Open Air Contact Drift Eliminator for Cooling Tower Systems
  • Open Air Contact Drift Eliminator for Cooling Tower Systems
  • Open Air Contact Drift Eliminator for Cooling Tower Systems
  • Open Air Contact Drift Eliminator for Cooling Tower Systems
Find Similar Products
  • Overview
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MBD
Condition
New
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Material
PVC
Transport Package
Wooden Case or 20gp/40gp Container
Specification
Height: 146 mm
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
500000/Year

Product Description

Introducing our Drift Eliminator, a precision-engineered solution crafted specifically for cooling tower applications, ensuring optimal efficiency and performance.

Open Air Contact Drift Eliminator for Cooling Tower Systems

MBD Newin MBD series cellular drift eliminator is an advanced design that effectively removes minute water droplets entrained in exhaust air. This innovative solution significanntly reduces potential health risks and annoyance caused by escaping droplets through the tower's top, which accompany the heated air. The MBD series is expertly engineered to produce a complex path for the air stream. As water droplets navigate through, they are compelled to alter their path, resulting in impacts against the eliminator's side walls. This process facilitates coalescence and redirects the water back into the cooling tower's wet section, enhancing efficiency and water conservation.
 


FEATURES

- Designed with anti-aging properties, our product boasts superior water absorption capabilities.
- Featuring low airflow resistance and exceptional structural strength, it excels in performance.
- Offers effortless installation paired with an impressive long service life for sustained use.
- Versatile enough to serve as a replacement for air inlet louvers, enhancing system adaptability.
Parameter

PROPERTIES

At Newin (Guangdong) Machinery Co., Ltd., we recognize the diverse needs for our MBD drift eliminators. Whether it's a specific length, width, material, or thickness, share your precise requirements with us to ensure a tailored solution and accurate offer. Our product line is designed to meet all customer specifications. Additionally, upon request, we offer fill media with flame retardant or anti-bacterial properties to enhance the safety and efficiency of your cooling systems.
Module Length (Max)  mm 2440
Module Width  (Max)  mm 500
Module Height  mm 146
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.38
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.



STRUCTURE & INSTALLATION DRAWING

Newin is proud to provide comprehensive support with structure and installation drawing guidance, ensuring seamless integration at your jobsite. We also offer jobsite storage advice and a detailed quality control report with every shipment to guarantee the highest standards upon material arrival. For specialized needs, we offer OEM services and can design custom molds to meet specific project demands. Your satisfaction and success are our priority.

Open Air Contact Drift Eliminator for Cooling Tower Systems
Application

APPLICATION & USAGE

The Newin MBD cellular drift eliminator is expertly designed for use in replacing cooling tower systems. Tested rigorously to SGS standards, in line with ASTM guidelines, this product ensures superior quality infill, maximizing the efficiency of your cooling tower. Simply provide us with your tower model or size, and we will expertly estimate the number of sheets required for your cooling tower replacement, ensuring seamless integration and enhanced performance.Open Air Contact Drift Eliminator for Cooling Tower Systems


Applicable Commercial Standards

Our sheet materials undergo strict testing, adhering to SGS standards and ASTM guidelines. We offer testing for each or all properties listed below, available at your request. This commitment guarantees the highest quality and reliability for your specific needs.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Cellular Drift Eliminator Replacement

Please provide the measurement data below for your cooling tower maintenance or repair projects. Demand the highest quality and reliability with Newin. Whether you require a site visit or maintenance services, our engineering expertise ensures the perfect fit of cooling tower fills or components, enhancing your system's performance.
Open Air Contact Drift Eliminator for Cooling Tower Systems
NEWIN Manufacturing Base

Open Air Contact Drift Eliminator for Cooling Tower Systems
NEWIN FACTORY
Embark on an inspiring journey through our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Spanning an expansive 10,000 square meters, this facility is a beacon of innovation and technological advancement. Immerse yourself in an environment where pioneering breakthroughs and excellence converge, setting new standards in manufacturing.

ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: ISO9001:2015 Quality Management and ISO14001:2015 Environmental Management. These certifications exemplify our dedication to setting industry benchmarks for excellence and responsible practices.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Open Air Contact Drift Eliminator for Cooling Tower Systems
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Immerse yourself in unrivaled efficiency and groundbreaking innovation with our Closed Type Cooling Tower Series. Each model is meticulously designed to deliver superior performance and unmatched reliability, embodying the pinnacle of cooling tower technology.
· NSH/ NST Discover the unwavering reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance. These towers set industry standards and consistently exceed expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty applications. These towers ensure resilience and power at every turn, meeting the demands of the most challenging environments.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models. These models set new standards in performance and operational excellence, revolutionizing the cooling industry with unparalleled innovation.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler. Expertly designed for superior airflow and maximum efficiency, this cooler optimizes every facet of cooling, delivering unmatched results.

Open Air Contact Drift Eliminator for Cooling Tower Systems
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit a variety of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories for optimal cooling tower performance.

CONTAIN:
· A robust Fan drive system, featuring a fan, fan stack, reducer, motor, and shaft. Engineered for durability and precision, this system ensures seamless operation.
· Highly efficient Water distribution components, with precision-engineered nozzles and advanced drift eliminators. These components optimize water management for superior performance.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils. Crafted for optimal performance and energy efficiency, these options enhance thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system. These accessories enhance overall functionality and efficiency, elevating performance.
 
Packaging & Shipping

Open type cooling towers shipment: Our meticulously engineered open-type cooling towers are expertly packaged, ensuring they reach you in immaculate condition. We prioritize the utmost safety and security, employing premium materials and strategic packing techniques to provide an impregnable shield against any potential transit damages. Revel in seamless logistics and prompt delivery, ensuring that your cooling solutions become operational without delay for maximum efficiency and performance. Relish in the peace of mind that comes with knowing your high-quality cooling systems are handled with the utmost care and precision, ready to boost productivity.

Open Air Contact Drift Eliminator for Cooling Tower Systems
Closed type cooling towers shipment: Experience peace of mind with our robust packaging solutions for closed-type cooling towers. Each unit is meticulously encased to endure the rigors of transport, ensuring arrival at your site in pristine condition and ready to deliver top-tier performance. Our steadfast dedication to quality control and punctual shipping empowers you to concentrate on what truly matters - harnessing our cutting-edge cooling technology to enhance your applications and achieve unparalleled outcomes. Trust in our commitment as your partner in progress, facilitating seamless integration and unwavering support for your success.
Open Air Contact Drift Eliminator for Cooling Tower Systems
Open Air Contact Drift Eliminator for Cooling Tower Systems
Technical Strength& Standards

Open Air Contact Drift Eliminator for Cooling Tower Systems
Open Air Contact Drift Eliminator for Cooling Tower Systems

Certifications

Open Air Contact Drift Eliminator for Cooling Tower SystemsOpen Air Contact Drift Eliminator for Cooling Tower SystemsOpen Air Contact Drift Eliminator for Cooling Tower SystemsOpen Air Contact Drift Eliminator for Cooling Tower Systems

Open Air Contact Drift Eliminator for Cooling Tower Systems



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More