Counter Flow Cooling Tower Drift Eliminator with Evapak Fill

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
  • Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
  • Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
  • Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
  • Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
  • Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
Find Similar Products
  • Overview
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
MBD
Condition
New
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Material
PVC
Transport Package
Wooden Case or 20gp/40gp Container
Specification
Height: 146 mm
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
500000/Year

Product Description

Our Drift Eliminator is meticulously engineered to elevate the efficiency and performance of your cooling tower.

Counter Flow Cooling Tower Drift Eliminator with Evapak Fill

MBD Newin MBD series cellular drift eliminator from Newin is a state-of-the-art solution designed to effectively remove those minute water droplets entrapped in the exhaust air, thereby significantly reducing potential nuisances and health hazards. This innovative series of drift eliminators are expertly designed to forge a complex path for the air stream. As water droplets navigate through this labyrinth, they are compelled to alter their direction, resulting in an impact against the drift eliminator's side walls. This process facilitates the coalescence and redirection of droplets back into the cooling tower's wet section, enhancing operational efficiency.
 


FEATURES

- Remarkably resistant to aging, coupled with superior water absorption capabilities.
- minimal airflow resistance, robust structural integrity.
- effortless installation paired with an extensive service life.
- versatile enough to serve as a replacement for air inlet louvers.
Parameter

PROPERTIES

At Newin (Guangdong) Machinery Co., Ltd., we welcome diverse requirements for MBD drift eliminators. Be it length, width, material type, or thickness, share your specific needs with us to receive an accurate and tailored solution. We cater to every customer requirement with precision. Additionally, upon request, we offer fill media in flame-retardant or anti-bacterial variants to meet your specialized needs.
Module Length (Max)  mm 2440
Module Width  (Max)  mm 500
Module Height  mm 146
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.38
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.



STRUCTURE & INSTALLATION DRAWING

Newin ensures a seamless experience by providing comprehensive structure and installation drawing guidance, along with detailed jobsite storage advice and a quality control report accompanying your shipment. This attention to detail facilitates smooth material reception. We also offer OEM services or custom mold designs upon request to better serve unique project specifications.

Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
Application

APPLICATION & USAGE

The Newin MBD cellular drift eliminator, crafted with precision and excellence, is ideally suited for replacing cooling towers. Rigorously tested under SGS standards alongside ASTM criteria, this product ensures superior quality infill, guaranteeing the ultimate efficiency of your cooling tower. Simply share your tower model or dimensions with us, and we'll expertly estimate the required number of sheets for your cooling tower replacement, ensuring a seamless and efficient upgrade.Counter Flow Cooling Tower Drift Eliminator with Evapak Fill


Applicable Commercial Standards

Our sheet materials adhere strictly to SGS testing protocols, aligned with ASTM standards. Whether you're in need of testing for individual properties or a comprehensive suite of evaluations, all necessary assessments are available upon request to ensure your product meets the highest standards.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Cellular Drift Eliminator Replacement

Provide the measurements below for your cooling tower maintenance or repair projects, where excellence and reliability are paramount. Trust in Newin for on-site visits or maintenance services engineered to custom-fit cooling tower fills or components, delivering unparalleled quality and performance.
Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
NEWIN Manufacturing Base

Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
NEWIN FACTORY
Embark on a journey of inspiration and innovation as you explore our state-of-the-art manufacturing base, strategically located in the bustling industrial epicenter of Huizhou, Guangdong. With an impressive expanse of 10,000 square meters, this facility stands as a testament to cutting-edge technology and visionary progress. Immerse yourself in an environment where pioneering advancements and excellence converge, setting unprecedented standards in the realm of manufacturing.

ISO CERTIFICATION
At Newin, we take immense pride in our steadfast dedication to superior quality and environmental responsibility, underscored by our esteemed ISO certifications: ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management. These accolades encapsulate our commitment to establishing industry benchmarks for excellence and sustainable practices.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Immerse yourself in a realm of unparalleled efficiency and groundbreaking innovation with our Closed Type Cooling Tower Series. Each model is expertly crafted to deliver top-tier performance and unmatched reliability, exemplifying the apex of cooling tower technology.
· NSH/ NST Experience the steadfast reliability of our Open Type Cooling Tower Series, engineered with precision for optimal operation and robust performance. These towers set industry benchmarks, consistently surpassing expectations with their enduring excellence.
· NTG Explore the formidable capabilities of our Industrial Type Cooling Tower Series, meticulously crafted to tackle the most demanding heavy-duty applications. These towers guarantee resilience and power at every turn, expertly meeting the challenges of any environment.
· NECN/NECH Integrate seamlessly cutting-edge efficiency with our state-of-the-art Evaporative Condenser models. These groundbreaking models redefine performance and operational excellence, revolutionizing the cooling industry with their unparalleled innovation.
· NWFL Harness the transformative power of cutting-edge technology with our Dry Air Cooler. Expertly designed for superior airflow and maximum efficiency, this cooler optimizes every facet of cooling, delivering results that are simply unmatched.

Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet all your maintenance and replacement needs. Customize your selection to fit a variety of cooling tower sizes and types. Reach out to us to tailor the perfect suite of accessories that ensure optimal cooling tower performance.

CONTAIN:
· A robust Fan drive system, featuring a fan, fan stack, reducer, motor, and shaft. Engineered with precision and durability in mind, this system guarantees seamless operation.
· Highly efficient Water distribution components, boasting precision-engineered nozzles and advanced drift eliminators. These components optimize water management for superior performance.
· Premium Heat exchange options, equipped with top-quality PVC infills and cooling coils. Designed for optimal performance and energy efficiency, these options enhance thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, crafted to seamlessly complete your system. These accessories boost overall functionality and efficiency, elevating performance.
 
Packaging & Shipping

Open type cooling towers shipment: Our meticulously engineered open-type cooling towers are expertly packaged, ensuring they reach you in immaculate condition. We prioritize the utmost safety and security, employing premium materials and strategic packing techniques to provide an impregnable shield against any potential transit damages. Revel in seamless logistics and prompt delivery, ensuring that your cooling solutions become operational without delay for maximum efficiency and performance.

Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
Closed type cooling towers shipment: Indulge in a seamless experience with our robust packaging solutions tailored for closed-type cooling towers. Each unit is meticulously encased to withstand the rigors of transportation, guaranteeing that it arrives at your site in pristine condition and primed for superior performance. Our unwavering dedication to exceptional quality control and timely shipping empowers you to focus on harnessing our advanced cooling technology. Elevate your applications and achieve extraordinary outcomes with confidence.
Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
Technical Strength& Standards

Counter Flow Cooling Tower Drift Eliminator with Evapak Fill
Counter Flow Cooling Tower Drift Eliminator with Evapak Fill

Certifications

Counter Flow Cooling Tower Drift Eliminator with Evapak FillCounter Flow Cooling Tower Drift Eliminator with Evapak FillCounter Flow Cooling Tower Drift Eliminator with Evapak FillCounter Flow Cooling Tower Drift Eliminator with Evapak Fill

Counter Flow Cooling Tower Drift Eliminator with Evapak Fill



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups