Experience unparalleled tranquility and performance with our Low Noise High Efficiency Water Cooling Tower. This masterpiece of engineering is meticulously crafted to cater to those who demand both silence and supreme efficiency in their cooling solutions.
Product Description
NST The NST series stands as the epitome of high-performance technology with its cross-flow design, embodying an induced draft open-loop cooling tower. This marvel is frequently employed across small and medium industrial sectors, air-conditioning units, and mechanical ventilation systems. Its versatility extends to projects that demand lower water quality, providing an efficient and reliable solution.
FEATURES
CTI Certified, Performance Assurance
> High Efficiency Cooling
- Innovative design with two-sided fully opened air intake ensures comprehensive air contact, amplifying cooling effectiveness.
- Expansive infills area enables superior heat exchange efficiency, driving unparalleled cooling performance.
- Dynamic high frequency transverse water flow fosters robust turbulent mixing, enhancing cooling efficiency to unprecedented levels.
> Maximise Resource Utilization
- Optimize water utilization by minimizing wastage. Promotes broad ventilation, significantly curbing energy consumption and improving sustainability.
- Predominantly recyclable materials fortify environmental protection efforts, safeguarding the planet for future generations.
> High Impact Resistant
- Engineered with a robust infills layer and internal framework, this structure boasts exceptional impact resistance, lowering the risk of infills damage and blockage.
> Ease to Operate & Maintain
- Featuring a corrosion-resistant main structure, this design ensures easy operation and maintenance, alongside reduced operating costs, delivering unrivaled convenience and efficiency.
MAIN PARTS
1. High Efficiency Axial Fan
> Renowned aluminum alloy axial fan brand offers superior performance, reduced power consumption, and exceptionally low noise for tranquil operation.
> Premium V-belt and pulley guarantee stable, smooth operation, and effortless maintenance, maximizing uptime.
> TEFC cooling tower duty motor available with optional gear reducer. Choose from two-speed, variable speed, or explosion-proof motor options for customized solutions.
> Upgrade to a Permanent magnetic direct drive system for reduced power usage, achieving energy efficiency ratings up to IE5.
2. Uniform Water Distribution System
> Gravity-driven, this system ensures even water distribution, providing consistent performance and optimal cooling.
> Features large diameter, non-clogging PP nozzles offering extensive spraying coverage for maximum efficacy.
> Removable steel cover facilitates easy inspection and maintenance, keeping the system running smoothly.
> Optional high-low flowrate nozzles ensure uniform water distribution, even under low flowrate conditions, ensuring adaptability in various scenarios.
3. Integrated Baffle Type Infill
> Constructed with high-quality, self-extinguishing PVC infill, ensuring safety and efficiency.
> Seamlessly integrated infill and drift eliminator provide a larger heat exchange area and impressive drift reduction below 0.005%, enhancing performance.
> Options for high or low temperature resistant infills are available to meet specific operating conditions, ensuring reliability across diverse environments.
4. Cold Water Basin
> Equipped with an automatic makeup water system, utilizing a stainless-steel mechanical float valve for corrosion resistance and exceptional flexibility.
> To address cold season requirements, a water basin heater installation is available, ensuring frost protection.
5. Heavy Duty & High Stability Structure
> The main framework boasts Z700 HDGS corrosion-resistant material, secured with 304 Stainless Steel bolts and nuts, promising unmatched durability and stability.
> Available in 304 / 316 Stainless Steel or NWN-Armour materials, offering versatile options to meet specific needs and environments.
6. SMC Compressed Moulded
> Fiberglass Fan Stack crafted from corrosion-resistant and UV-resistant fiberglass material, ensuring long-lasting performance.
> Enhances airflow uniformity within the tower and reduces airflow resistance, ensuring the fan operates with peak efficiency.
7. High Quality Fiberglass Panel
> Constructed from durable, corrosion and UV-resistant fiberglass material, guaranteeing longevity and resilience in diverse conditions.
> The innovative corrugated design significantly enhances durability, effectively extending the lifespan of the product, ensuring it withstands the test of time.
> Choose from premium materials: 304 / 316 Stainless Steel or the robust NWN-Armour, offering unmatched resilience and reliability for your unique requirements.
8. Access Door
> Designed for your convenience, the access door facilitates seamless entry for thorough inspection and maintenance of the tower, ensuring optimal performance at all times.
9. Maintenance Platform
> Engineered with a secure double-layer maintenance platform, this design elevates safety and convenience, particularly during essential fan maintenance and internal cooling tower servicing.
10. Cage Ladder & Handrail
Product Parameters
Tower Model |
Outline dimensions (mm) |
Weight (Kg) |
NST |
W |
L |
H |
Dry |
Wet |
NST-18-A15-2A11-C1 |
3310 |
1800 |
3500 |
1030 |
2480 |
NST-20-B15-2A12-C1 |
3310 |
2000 |
3700 |
1110 |
2730 |
NST-26-D18-3A14-C1 |
4080 |
2600 |
4110 |
1660 |
4130 |
NST-30-D21-3A16-C1 |
4220 |
3000 |
4540 |
1890 |
4860 |
NST-33-E24-3A17-C1 |
4540 |
3300 |
4790 |
2080 |
5520 |
NST-35-F26-4A17-C1 |
5350 |
3500 |
4890 |
2960 |
8290 |
NST-40-F30-4B17-C1 |
5750 |
4000 |
4940 |
3310 |
9690 |
NST-43-G32-4B18-C1 |
5950 |
4300 |
5140 |
3550 |
10620 |
NST-46-H34-4B20-C1 |
6150 |
4600 |
5560 |
3900 |
11740 |
NST-48-H40-5B18-C1 |
7420 |
4800 |
5390 |
4560 |
13970 |
NST-50-I42-5B20-C1 |
7560 |
5000 |
5610 |
5190 |
15280 |
NST-54-J42-5B22-C1 |
7560 |
5400 |
6010 |
5650 |
16690 |
NST-60-J47-5B22-C1 |
8040 |
6000 |
6210 |
6330 |
19120 |
Explore the Enhanced NST Series FRP Cooling Tower Solutions - Crafted to Satisfy Diverse Operational Conditions Efficiently.
OPTIONS
Advanced Permanent Magnetic Direct-Driven Fan System
Innovative Energy Saving Design
> Experience variable frequency control that promotes low-speed functioning, ensuring exceptional efficiency and an elevated power factor.
> Benefit from a direct-driven fan system, eliminating transmission losses while being completely maintenance-free.
> Achieve an outstanding energy efficiency rating of up to IE5, delivering substantial savings in power and energy usage.
NWN-Armour Corrosion Resistant Technology
Superior Corrosion Resistant Design
Crafted with galvanized steel panels coated in continuously enhanced NWN-Armour anti-corrosion technology. This design offers corrosion resistance comparable to Stainless Steel, presenting a cost-effective alternative to Stainless Steel materials.
Additional Accessories
Comprehensive Options: PLC Control System, Side Stream Filtration System, Davit Arm, and Noise Level Reduction - Tailored for Optimal Performance.
NEWIN Manufacturing Base
Explore the Impressive Facilities at NEWIN FACTORY
Our state-of-the-art manufacturing base is strategically located in Huizhou, Guangdong, sprawling over an expansive 10,000 square meters of innovation and productivity.
Prestigious ISO CERTIFICATION
Achieving excellence with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification.
Sophisticated WORKSHOPS
Precision and Expertise at the Welding Workshop
Innovative Solutions in the Filler Thermoforming Workshop
Cutting-edge Techniques in the Sheet Metal Processing Workshop
Advanced Cooling Tower Assembly Workshop
TESTING Excellence
Our Independent Testing LAB ensures the highest standards of quality and performance.
NEWIN COOLING TOWERS: Engineered for Optimal Performance
·
NWN/ NWF/ NCFN Discover the efficiency of our Closed Type Cooling Tower Series.
·
NSH/ NST Explore the versatility of our Open Type Cooling Tower Series.
·
NTG Industrial Type Cooling Tower Series: Robust and Reliable.
·
NECN/NECH Evaporative Condenser: Advanced cooling technology.
·
NWFL Efficient Cooling with our Dry Air Cooler.
NEWIN provides a comprehensive range of cooling tower accessories to fulfill maintenance and replacement needs for diverse cooling tower models and sizes. Contact us to personalize the accessories for your specific requirements.
All-Inclusive CONTAIN:
· Fan drive system (including fan, fan stack, reducer, motor, shaft, and more)
· Water distribution systems (such as nozzles and drift eliminators)
· Heat exchange components (featuring PVC infills, cooling coils, and others)
· Additional accessories (like air inlet louvers, valves, etc.)
Packaging & Shipping
Open Type Cooling Towers Shipment: Our commitment to excellence shines through in the secure and efficient shipping of our open type cooling towers, guaranteeing that they reach you without a hitch.
Closed Type Cooling Towers Shipment: With precision and reliability, our closed type cooling towers are shipped with unparalleled care, ensuring a seamless delivery experience.
Technical Strength& Standards
Certifications