400 Ton FRP Material Open Type Cross Flow Cooling Tower

Product Details
Customization: Available
Cooling Method: Cross Flow
Ventilation Mode: Mechanical Ventilation
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 400 Ton FRP Material Open Type Cross Flow Cooling Tower
  • 400 Ton FRP Material Open Type Cross Flow Cooling Tower
  • 400 Ton FRP Material Open Type Cross Flow Cooling Tower
  • 400 Ton FRP Material Open Type Cross Flow Cooling Tower
  • 400 Ton FRP Material Open Type Cross Flow Cooling Tower
  • 400 Ton FRP Material Open Type Cross Flow Cooling Tower
Find Similar Products

Basic Info.

Model NO.
NST-400/D
Material
Metal
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Nominal Flow
400 M3/H
Motor Power
7.5*2 Kw
Fan Diameter
2400 Mm
Net Weight
3040 Kg
Running Weight
7650 Kg
Water Pressure
40 Kpa
Transport Package
20/40/40hq Container with Loose Packing
Specification
CTI
Trademark
NEWIN
Origin
China
HS Code
84195000
Production Capacity
15000 Sets / Year

Product Description

400 Ton FRP Material Open Type Cross Flow Cooling Tower

400 Ton FRP Material Open Type Cross Flow Cooling TowerNST series cross flow square  cooling tower is available in capacity for single cell from 100 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements.This cooling tower is highly used in heating, ventilation, air-conditioning, and light to medium processing applications.

Features

- Adopts Cross flow open-loop technology, enough air inlet from both side.
- Even spray water distribution, Efficient heat exchanger pvc layer.
- Zinc-Aluminum steel frame, F.R.P tower body, Resistant to acid and alkali.
- Modular design,high strength, good rigidity, nice appearance.

400 Ton FRP Material Open Type Cross Flow Cooling TowerSpace Saving, Light-duty Structures
Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly.

Energy Saving, Low Noise
Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Double speed motor for optional to power saving according to customers' special requirements.
Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). 


Good Corrosion Resistance
Tower casing, tank and panel are made up of high corrosion resistance performance FRP material, and Galvanized steel structure improves the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life.

Convenient Combination and Easy Manitenance
Combinations can be used to meet the requirements of different working condition.If limited space in end user, we can also design for the special cooling tower to meet users' requirements for the performance of thermal and noise.


Components Instruction
400 Ton FRP Material Open Type Cross Flow Cooling Tower

Motor
Fully enclosed type, with protection grade: IP55,   and insulation class:  F.  Smooth operation, low failure rate. Options: Siemens, ABB motor, etc.

Fan and Reducer
Adopting low speed, big chord length and width of blade fan, with characteristic of stable wind speed, low noise, few eddy current and high efficiency, etc. Enough air flow can be easily get at low rotating speed of the fan, what's more, the cooling tower fan blade angle can also be adjusted according to different climate condition, therefore, the cooling tower can not only be ensured in the rough conditions but meet the operation requirements of users.

Infill
Brand new PVC infill is vacuum formed of 0.3 thickness or more thicker PVC film with excellent chemical and high distortion resistance, big coefficient of heat transfer, small wind resistance, high ventilation performance. 
We have different materials to suit different water temperature. What's more, the PVC filler's compact package design is convenient to take out for cleaning, and the special designed configuration of the filling incorporates the function of drift eliminator, louver and wet deck surface.


Steel Structure
Hop-dip galvanized steel framework to keep the cooling tower great performance and long lifespan, good anti-corrosion, guarantee the use of more than 15 years. Stainless steel hardware parts are also available for options if somewhere special condition needed.

Distribution System
Hot water distribution system is used F.R.P parts, non-corrosive and long life, and are specially designed for uniform distributing and ease of inspection. A distribution cover is attached on top to prevent    water from splashing out and other dirt to come into the water.   

Inspection Door
Inspection doors are used to provide a convenient access to the interior for inspection, maintenance, adjustment of the internal parts, like float valve, cleaning up the lift-out strainer and flushing of the water basin.
 

400 Ton FRP Material Open Type Cross Flow Cooling Tower

Technical Specification of NST Series Cooling Tower
 
Model Cooling Capacity
(RT)
Motor
kw
Fan Diameter
mm
Dimension (mm) Water Inlet
DN
Water Outlet
DN
Weight (kg)
H W L Dry Wet
NST-19-A16-3A12-C1 100 3(A) 1600 3680 3800 1900 100*2 125 1250 2650
NST-22-B16-3A12-C1 125 4(B) 1600 380 3800 2200 125*2 150 1350 2750
NST-22-B18-3A14-C1 150 4(B) 1800 4080 4010 2200 125*2 150 1450 2950
NST-26-C22-3A14-C1 175 5.5(C) 2200 4080 4420 2600 125*2 200 1550 3250
NST-26-C22-3A15-C1 200 5.5(C) 2200 4280 4420 2600 150*2 200 1720 3530
NST-26-D22-3A16-C1 225 7.5(D) 2200 4480 4420 2600 150*2 200 1820 4170
NST-30-D24-3A16-C1 250 7.5(D) 2400 4680 4620 3000 150*2 250 2280 4700
NST-30-D24-4A14-C1 300 7.5(D) 2400 4280 5230 3000 150*2 250 2620 5470
NST-30-E24-4A16-C1 350 11(E) 2400 4680 5230 3000 150*2 250 2750 5700
NST-33-E28-4B18-C1 400 11(E) 2800 5130 5640 3300 150*4 300 3050 6600
NST-33-F28-4B20-C1 450 15(F) 2800 5500 5640 3300 150*4 300 3450 7000
NST-38-F28-4B20-C1 500 15(F) 2800 5500 5640 3800 150*4 300 3750 7800
NST-38-F34-4B20-C1 550 15(F) 3400 5630 6240 3800 150*4 350 4250 8600
NST-46-G34-4B20-C1 600 18.5(G) 3400 5630 6240 4600 150*4 350 4850 10200
NST-46-G36-4B22-C1 700 18.5(G) 3600 6030 6450 4600 150*4 350 5250 14500
NST-51-I36-4B22-C1 800 30(I) 3600 6080 6450 5100 200*4 400 5650 15500
NST-53-I42-4B24-C1 900 30(I) 4200 6530 7060 5300 200*4 400 6450 17800
NST-53-J42-4B26-C1 1000 37(J) 4200 6930 7440 5300 200*4 400 7150 19500

400 Ton FRP Material Open Type Cross Flow Cooling Tower
Open Type Cross Flow Cooling Tower NST-S series Stainless Steel Cooling Tower

400 Ton FRP Material Open Type Cross Flow Cooling Tower
NST-S series Full-Steel Cross Flow Square Cooling Tower is available in capacity for single cell from 100 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements.This cooling tower is highly used in heating, ventilation, air-conditioning, and light to medium processing applications.

Features

- Adopts Cross flow open-loop technology, enough air inlet from both side, even spray water distribution, efficient heat exchanger pvc layer.
- Full-Steel Modular design, adopts Zinc-Aluminum/Stainless steel 304 /316L material, high strength, good rigidity, nice appearance.
- Resistant to acid and alkali, effectively eliminate the oxidation on the surface of the galvanized/Stainless steel 304 /316L.



Cross Flow Cooling Tower Structure

400 Ton FRP Material Open Type Cross Flow Cooling Tower

400 Ton FRP Material Open Type Cross Flow Cooling Tower

Components Instruction


CASING AND BASIN
Using 304/316 stainless steel materials plate, high strength , high corrosion resistant and light weight.

FAN & DRIVING SYSTEM
Adopting low speed, big chord length, and width of blade fan, with stable wind speed, low noise, and high efficiency, etc. Enough airflow can easily get at low rotating speed of the fan, what's more, blade angle can be adjusted according to different climate conditions. Used aluminum alloy fan blades, solid fan or hollow type available for different customers' request.
Using motor with IP55 protection grade, F class insulation grade, smooth operation, low failure rate. Options: Siemens, ABB

DISTRIBUTION SYSTEM
Using the unique overflow device to realize smooth and even water distribution under different system load, the device completely eliminates the drift loss of coolig tower. Hot water basin cover avoids water pollution by foreign objects falling into hot basin. Meantime, it avoids direct sunlight and inhabit growth of algae.

FILL PACKING
Used high quality & improved performance PVC with good material, it is high cooling efficiency and anti-corrosive & UL V-0. Brand new PVC materials, integrated eliminators and louvers. The infills are hanging type, environmental friendly and  big coefficient of heat transfer, good hydrophilicity. Small wind resistance, high ventilation performance. Special material for option if high entering water temperature.

FRAME STRUCTURE AND FASTENERS
Leading structure design and high-quality materials to make frame structure and fasteners, the standard configuration of structure and fasteners is superior hot-dip galvanized steel, good anti-corrosion, design lifespan is more than 15 years. Stainless steel or F.R.P frame structure available for poor water soltion, and SUS304 or SUS316L for fasteners.  


400 Ton FRP Material Open Type Cross Flow Cooling Tower


Technical Specification of NST-S/SS Series Cooling Tower
 
Model Cooling Capacity
(RT)
Motor
kw
Fan Diameter
mm
Dimension (mm) Water Inlet
DN
Water Outlet
DN
Weight (kg)
H W L Dry Wet
NST-S/SS-19-A16-3A12-C1 100 3(A) 1600 3680 3800 1900 100*2 125 1250 2650
NST-S/SS-22-B16-3A12-C1 125 4(B) 1600 380 3800 2200 125*2 150 1350 2750
NST-S/SS-22-B18-3A14-C1 150 4(B) 1800 4080 4010 2200 125*2 150 1450 2950
NST-S/SS-26-C22-3A14-C1 175 5.5(C) 2200 4080 4420 2600 125*2 200 1550 3250
NST-S/SS-26-C22-3A15-C1 200 5.5(C) 2200 4280 4420 2600 150*2 200 1720 3530
NST-S/SS-26-D22-3A16-C1 225 7.5(D) 2200 4480 4420 2600 150*2 200 1820 4170
NST-S/SS-30-D24-3A16-C1 250 7.5(D) 2400 4680 4620 3000 150*2 250 2280 4700
NST-S/SS-30-D24-4A14-C1 300 7.5(D) 2400 4280 5230 3000 150*2 250 2620 5470
NST-S/SS-30-E24-4A16-C1 350 11(E) 2400 4680 5230 3000 150*2 250 2750 5700
NST-S/SS-33-E28-4B18-C1 400 11(E) 2800 5130 5640 3300 150*4 300 3050 6600
NST-S/SS-33-F28-4B20-C1 450 15(F) 2800 5500 5640 3300 150*4 300 3450 7000
NST-S/SS-38-F28-4B20-C1 500 15(F) 2800 5500 5640 3800 150*4 300 3750 7800
NST-S/SS-38-F34-4B20-C1 550 15(F) 3400 5630 6240 3800 150*4 350 4250 8600
NST-S/SS-46-G34-4B20-C1 600 18.5(G) 3400 5630 6240 4600 150*4 350 4850 10200
NST-S/SS-46-G36-4B22-C1 700 18.5(G) 3600 6030 6450 4600 150*4 350 5250 14500
NST-S/SS-51-I36-4B22-C1 800 30(I) 3600 6080 6450 5100 200*4 400 5650 15500
NST-S/SS-53-I42-4B24-C1 900 30(I) 4200 6530 7060 5300 200*4 400 6450 17800
NST-S/SS-53-J42-4B26-C1 1000 37(J) 4200 6930 7440 5300 200*4 400 7150 19500


400 Ton FRP Material Open Type Cross Flow Cooling Tower


NEWIN NST cooling tower project cases

400 Ton FRP Material Open Type Cross Flow Cooling Tower

Cooling Tower Shipment

400 Ton FRP Material Open Type Cross Flow Cooling Tower

NEWIN COOLING TOWER


400 Ton FRP Material Open Type Cross Flow Cooling Tower
400 Ton FRP Material Open Type Cross Flow Cooling Tower
400 Ton FRP Material Open Type Cross Flow Cooling Tower


400 Ton FRP Material Open Type Cross Flow Cooling Tower400 Ton FRP Material Open Type Cross Flow Cooling Tower400 Ton FRP Material Open Type Cross Flow Cooling Tower
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier