Introducing the Newin NWN Counter Flow Closed Type Cooling Tower-a pinnacle of innovation in cooling technology.
NWNThe NWN series offers a revolutionary counter flow closed type cooling tower, engineered with a closed loop system. This advanced design supports dry operation mode without the need for spray water during winter months, effectively replacing traditional chillers. As a result, it significantly reduces energy consumption and operational costs.
Operational Excellence: Experience superior cooling efficiency as the fluid medium circulates within the high-performance serpentine heat exchanger. The external spray system persistently moistens the coil surface, enhancing cooling effectiveness. This process ensures the medium is optimally cooled as it navigates through the partition heat exchanger, coupled with strategic spray water heat exchange.
Features
- Experience the brilliance of pure coil cooling, capable of handling high-temperature water effortlessly, enabling an efficient and effective heat exchange process.
- Embrace the innovation of a closed-loop system-it's not just about clean medium; it's about an energy-efficient, water-conserving marvel that resists scaling.
- Enjoy the benefits of a compact, economically-space-optimizing structure that ensures ease of shipping and a breeze of installation.
COOLING TOWER PARTS
1. Axial Flow Fan
Harness the power of a cooling tower's specialized aluminum alloy axial flow fan. Its forward-type blade structure design minimizes wind resistance while maximizing air volume, performance, and efficiency with low noise. The streamlined, high-strength fan stack ensures uniform airflow through the fan inlet and outlet area, significantly reducing energy consumption. The fan motor is well-protected with an IP55 protection class and an F-class insulation. Choose from options like a two-speed, VFD, or anti-explosion motor for customized performance.
2. EVD PVC Drift Eliminator
Masterfully engineered, the EVD PVC Drift Eliminator efficiently extracts airborne water droplets with minimal wind resistance and boasts an impressive 99.99% capture rate, ensuring optimal heat transfer performance at all times.
3. Uniform Water Distribution
Discover the precision of strategically positioned Three-splashed-Nozzles, delivering even water distribution under low-pressure flow. The large caliber and three-splash design minimize blockages while enhancing spray coverage, guaranteeing continuous effective spraying and ensuring the cooling tower's efficient performance.
4. Stainless Steel Heat Exchange Coil
Our high-quality heat exchange coil boasts a stainless steel serpentine bending tube supported by a robust framework. This ensures superior thermal performance through full contact with spray water, fostering efficient heat exchange and effective cooling. The stainless steel pipes are resistant to corrosion, lightweight, and recyclable, offering a lasting environmental solution.
5. EVL Inlet Grille
The special 3D stereo 45-degree ventilation channel significantly enhances product rigidity and wind load resistance, offering unparalleled strength.
Engineered to reduce noise while preventing algae growth, transforming your cooling tower experience.
Designed to be anti-corrosion, anti-ultraviolet, and maintenance-free, for a worry-free operation.
6. Heavy-duty Construction
Built with high-quality Z700 galvanized steel frame and shell, offering robust corrosion resistance. In particularly harsh environments, choose the optional SUS314/316 or NWN-Armour anti-corrosion coated steel for exceptional protection.
Options
· Vibration Cut-off Switch
· Elevate your experience with a noise reduction upgrade.
· Electronic descaler for superior maintenance.
· Advanced water treatment equipment.
· Anti-freeze automatic heating system, ready for any climate.
NWN-Armour Corrosion Resistant Technology
Corrosion Resistant Design
Our galvanized steel panel is robustly fortified with the cutting-edge NWN-Armour anti-corrosion coating. It boasts corrosion resistance that rivals stainless steel, presenting a cost-effective alternative that significantly enhances both durability and longevity.
Product Parameters
Design Conditions
Entrance Temperature: A refreshing 37ºC Leaving Temperature: A cool 32ºC
Wet Bulb Temperature: A comfortable 28ºC Dry Bulb Temperature: A pleasant 31.5ºC Atmospheric Pressure: Optimal at 9.94 x 10 Pa
NWN |
Dimension (mm) |
Weight (kg) |
Model |
L |
W |
H |
Dry |
Wet |
NWN-60-Z7-S |
1800 |
900 |
2580 |
650 |
1050 |
NWN-90-Z7-S |
1800 |
900 |
2680 |
700 |
1100 |
NWN-120-Z7-S |
2300 |
1100 |
2520 |
850 |
1600 |
NWN-180-Z7-S |
2850 |
1100 |
2570 |
1100 |
2000 |
NWN-230-Z7-S |
2850 |
1100 |
2780 |
1150 |
2100 |
NWN-290-Z7-S |
2850 |
1100 |
2780 |
1250 |
2200 |
NWN-350-Z7-S |
2850 |
1200 |
2940 |
1400 |
2500 |
NWN-450-Z7-S |
4600 |
1450 |
3140 |
2700 |
3800 |
NWN-600-Z7-S |
4600 |
1450 |
3140 |
2900 |
4100 |
NWN-750-Z7-S |
4650 |
1750 |
3610 |
3400 |
5200 |
NWN-850-Z7-S |
4650 |
2250 |
3740 |
3800 |
6200 |
NWN-1000-Z7-S |
4650 |
2250 |
3910 |
4000 |
6500 |
NWN-1150-Z7-S |
6200 |
2250 |
4020 |
4800 |
8500 |
NWN-1300-Z7-S |
6200 |
2250 |
4020 |
5000 |
8800 |
NWN-1450-Z7-S |
6250 |
2500 |
4280 |
5400 |
9700 |
NWN-1750-Z7-S |
6250 |
3000 |
4380 |
6100 |
11200 |
Reference Projects
The pioneering NEWIN NWN series closed type cooling tower showcases remarkable versatility, finding extensive applications across diverse sectors: from the environmentally conscious Eco-Industry, to the innovative New Energy Industry, the precision-driven Chemical Industry, vital Test Centres, efficient Boiler Cooling systems, and robust Furnace Cooling solutions. Experience the synergy of advanced cooling technology tailored to meet your industry's dynamic cooling demands with unmatched efficiency and reliability.
NEWIN Manufacturing Base
NEWIN FACTORY: The Pinnacle of Precision and Quality
Manufacturing Base Situated in Huizhou, Guangdong. Spanning an impressive area of 10,000 square meters, our facility is a testament to our commitment to cutting-edge machinery and superior craftsmanship.
ISO CERTIFICATION: Exemplifying Standards and Quality Assurance
Certified with ISO9001:2015 for Quality Management Systems and ISO14001:2015 for Environmental Management Systems. These certifications underscore our dedication to outstanding quality and sustainable practices.
WORKSHOPS: Where Expertise Meets Innovation
Welding Workshop: Precision in Every Weld, Craftsmanship in Every Joint
Filler Thermoforming Workshop: Molding Excellence, Shaping the Future
Sheet Metal Processing Workshop: Forging Strength and Reliability
Cooling Tower Assembly Workshop: Assembling Efficiency, Building Performance
TESTING: Ensuring Unmatched Quality and Performance
Independent Testing LAB: Rigorous Assessments for Superior Outcomes
NEWIN COOLING TOWERS: Engineered for Excellence
·
NWN/ NWF/ NCFN: Innovatively Designed Closed Type Cooling Tower Series Closed Type Cooling Tower Series: Engineered for Optimal Thermal Efficiency
·
NSH/ NST: Leading-Edge Technology in Open Type Cooling Tower Series Open Type Cooling Tower Series: Unmatched in Performance and Reliability
·
NTG: Industrial Type Cooling Towers Built for Rigorous Demands Industrial Type Cooling Tower Series: Robust Solutions for Industrial Needs
·
NECN/NECH: Pioneering Evaporative Condensers for Modern Applications Evaporative Condenser: Maximum Efficiency, Zero Compromise
·
NWFL: Innovative Dry Air Cooler for All-Weather Performance Dry Air Cooler: Advanced Technology for Dependable Cooling
NEWIN manufactures and stocks a comprehensive range of cooling tower accessories to cater to maintenance and replacement requirements of virtually any size and type of cooling tower. Reach out to us to customize the cooling tower accessories tailored to your specifications.
CONTAIN: A Full Spectrum of Essential Components
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.): Precision-engineered for optimum performance
· Water distribution (nozzles/ drift eliminator etc.): Ensuring even flow and effective distribution
· Heat exchange (PVC infills/ cooling coil etc.): Superior materials for enhanced transfer efficiency
· Other accessories (air inlet louver/ valve etc.): Quality components for seamless operation
Packaging & Shipping
Open Type Cooling Towers Shipment: Delight in the flawless shipping experience of our Open Type Cooling Towers, crafted with precision for optimal air conditioning efficiency. Each unit is meticulously transported, adhering to the highest standards of quality and safety, ensuring they arrive in pristine condition and are fully prepared to elevate your cooling operations to new heights.
Closed Type Cooling Towers Shipment: Indulge in the peace of mind offered by our Closed Type Cooling Towers shipping process, where safety and reliability are paramount. From our cutting-edge facilities, these durable and highly efficient cooling systems embark on a secure journey to your location, ready to provide unparalleled cooling performance and satisfy your every cooling requirement.
Technical Strength& Standards
Certifications