High Frequency Closed Circuit Cooling Tower for Optimal Performance

Product Details
Customization: Available
After-sales Service: Consult Newin Sales Representative
Warranty: Consult Newin Sales Representative
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • High Frequency Closed Circuit Cooling Tower for Optimal Performance
  • High Frequency Closed Circuit Cooling Tower for Optimal Performance
  • High Frequency Closed Circuit Cooling Tower for Optimal Performance
  • High Frequency Closed Circuit Cooling Tower for Optimal Performance
  • High Frequency Closed Circuit Cooling Tower for Optimal Performance
  • High Frequency Closed Circuit Cooling Tower for Optimal Performance
Find Similar Products
  • Overview
  • Features
  • Reference Projects
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NCFN-GS
Cooling Method
Dry Wet Hybrid Cooling
Ventilation Mode
Forced Draft
Material
Aluminum Zinc
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ordinary
Application Fields
Industial & Air Conditioning
Certification
ISO, CE, CTI
Condition
New
Model
Ncfn-GS-L-850/1150/1300
Cooling Capacity
863kw to 1793kw
Free Cooling
Capacity 120kw to 247kw ( Under 12/7/0 Celsius)
Fan Motor Without Silencer
11kw to 37kw
Transport Package
Container
Specification
CE, UL, CTI
Trademark
NEWIN
Origin
Shenzhen China
HS Code
84195000
Production Capacity
1000sets/Month

Product Description

Revolutionary Advanced Dry-Wet Hybrid Cooling Tower: Engineered for Superior Heat Dissipation Efficiency

High Frequency Closed Circuit Cooling Tower for Optimal Performance
Features
NCFN-GS Series Dry-Wet Hybrid Forced Draft Closed Cooling Tower

The innovative NCFN-GS series cooling system masterfully combines the distinct elements of both wet and dry cooling, expertly delivering unparalleled cooling efficiency, significantly reduced energy consumption, and remarkable water conservation regardless of fluctuating ambient temperatures. This system thrives in arid desert regions and withstands harsh cold climates. Its advanced forced draft system ensures a remarkably low-noise operation, making it the ultimate cooling solution for areas with poor ventilation and noise sensitivity.
High Frequency Closed Circuit Cooling Tower for Optimal Performance

ADVANTAGE
 
High Frequency Closed Circuit Cooling Tower for Optimal Performance

Dry-Wet Hybrid Cooling Mode

NCFN-GS cooling tower is engineered to intelligently adapt its operational modes, responding dynamically to changes in ambient temperature for optimal performance.

Dry Cooling Mode
During temperatures below -10ºC or when the output temperature is beneath the set threshold, the spray pump halts its operation, seamlessly transitioning the cooling tower to dry cooling mode. This transition effectively curtails water evaporation in cold seasons and provides an ice water alternative to traditional refrigeration, fostering notable water and energy savings.

Wet Cooling Mode
When ambient conditions exceed a certain threshold (-2ºC) or the output temperature rises above a preset level, the spray pump activates, ushering the cooling tower into wet cooling mode. This mode harnesses the power of evaporative cooling to deliver robust cooling capacity.


Water saving, Energy conservation, Environmental protection

> Compared to traditional wet cooling towers, the system significantly reduces spray water usage, leading to overall water consumption reduction.
> Incorporating intelligent control systems and state-of-the-art cooling technology, this system efficiently reduces energy consumption and enhances energy utilization, resulting in substantial electricity savings.
> The dry-wet hybrid cooling design sharply minimizes water mist emissions, leading to a lower environmental footprint and improved eco-friendliness.

High Frequency Closed Circuit Cooling Tower for Optimal Performance

High Frequency Closed Circuit Cooling Tower for Optimal Performance

Operation& Maintenance Cost Saving

> The closed-circuit circulation design ensures the purity of the cooling medium, minimizing water contamination and slashing water treatment costs. Additionally, utilizing dry cooling mode during winter dramatically decreases the risk of freezing components, reducing operation and maintenance expenses while ensuring long-term stable equipment performance.
> Factory-assembled, the product is designed for seamless transportation and installation, ultimately conserving valuable time and effort.



MAIN PARTS
 

Forced Draft Centrifugal Fan Drive System

This premier centrifugal fan, proudly bearing the AMCA Seal for air performance, sound, and FEG, features precision-engineered wheel blades and belt pulley driving. It has undergone meticulous static and dynamic testing, ensuring a balance to the G2.5 grade, which optimizes cooling tower heat transfer performance while maintaining minimal noise. It boasts a substantial air volume with a flow range from 1000m3h-100000m3h, showcasing robust stability, impressive efficiency, low noise levels, and reduced power consumption.

High Frequency Closed Circuit Cooling Tower for Optimal Performance
 

Key Parts for Closed Circuit System And Dry-Wet Cooling Modes.

The cooling-required fluid medium circulates smoothly through the
fin tube heat exchanger and stainless steel heat exchange coil within the closed circuit system, ensuring pristine cleanliness, significantly reducing water treatment and maintenance costs, and conserving vital water resources while providing efficient cooling.

Fin tube heat exchanger and stainless steel heat exchange coil are not merely essential components of closed circuit systems, but also vital elements of Dry-wet cooling modes.
 

 
High Frequency Closed Circuit Cooling Tower for Optimal Performance

Finned Tube Heat Exchanger

Our fin tube heat exchanger is expertly crafted with high-grade stainless steel tubes and aluminum spiral fins. This construction not only ensures robust anti-corrosion properties but also significantly enhances the stability of the exchanger.. The ingenious structural design of the fin tube is meticulously optimized to expand the heat exchange area, thereby maximizing efficiency in heat transfer. This allows for a complete and seamless air exchange with the fin tube, ultimately facilitating water-saving operations during both the dry cooling and wet cooling phases. Moreover, it effectively prevents the formation of 'white smoke' during the winter operations of the cooling tower. This crucial feature ensures a favorable working environment for the equipment, significantly extending its service life.

 


Stainless Steel Heat Exchange Coil

Our high-quality heat exchange coil features a meticulously designed stainless steel serpentine bending tube along with a robust framework, delivering exceptional thermal performance by ensuring full contact with spray water. This design guarantees efficient heat exchange and highly effective cooling. The stainless steel heat exchange pipes stand out for their exceptional resistance to corrosion, all while being lightweight and fully recyclable.

High Frequency Closed Circuit Cooling Tower for Optimal Performance

High Frequency Closed Circuit Cooling Tower for Optimal Performance
Optional Various Additional Functions
Enhance your experience with our range of optional features: Two-speed and VFD variable frequency motors, vibration cut-off switch, electronic descaler, water treatment equipment, anti-freeze automatic heating system, noise reduction upgrades, external maintenance platform and guardrail, as well as installation and maintenance boom, etc.
 

Cost-effective Anti-Corrosion Solution
NWN-Armour Anti-corrosion Technology

Our NWN-Armour anti-corrosion coating empowers products with outstanding resistance to corrosion, rivaling the qualities of stainless steel. This technology provides a remarkably cost-effective alternative to stainless steel.
High Frequency Closed Circuit Cooling Tower for Optimal Performance
Reference Projects

High Frequency Closed Circuit Cooling Tower for Optimal Performance

Product Parameters

High Frequency Closed Circuit Cooling Tower for Optimal Performance

Model Wet Cooling Free Cooling Fan Motor Spray Pump Total Dimension
(without silencer)
Weight
Fluid flow Cooling capacity Capacity
12/7/0ºC
Power Power L W H Shipping Operation
m³/h kW kW kW kW mm mm mm kg kg
NCFN-GS-L-510-F 66 340 77 5.5  2.2  4680 2200 2920 3468 5184
NCFN-GS-L-510-S 66 340 108 7.5  2.2  4680 2200 3040 3636 5421
NCFN-GS-L-640-S 97 499 111 7.5  2.2  4680 2200 3240 3908 5812
NCFN-GS-L-640-E 97 499 142 11.0  2.2  4680 2200 3360 4082 6041
NCFN-GS-L-1000-F 119 612 139 15.0  4.0  6920 2200 2990 5438 8061
NCFN-GS-L-1000-S 119 612 211 18.5  4.0  6920 2200 3110 5647 8213
NCFN-GS-L-1250-S 175 900 218 22.0  4.0  6920 2200 3310 5898 8698
NCFN-GS-L-1250-E 175 900 273 30.0  4.0  6920 2200 3430 6107 9019
NCFN-GS-L-1560-F 225 1158 206 37.0  5.5  7520 2400 3190 6291 9928
NCFN-GS-L-1560-S 225 1158 273 37.0  5.5  7520 2400 3310 6534 10311
NCFN-GS-L-1560-E 225 1158 273 45.0  5.5  7520 2400 3430 6777 10694
Note:
1. Standard Design Working Condition: Fluid in/out temperature: 35/30ºC.
2. Standard design ambient wet/dry bulb temperature: 21/31ºC.
3. Above data sheet based on 40% ethylene glycol solution fluid.
4. Please contact NEWIN sales representative if working condition not same as above standard design condition.
 
NEWIN Manufacturing Base

High Frequency Closed Circuit Cooling Tower for Optimal Performance
NEWIN FACTORY
Nestled in the vibrant Huizhou, Guangdong, our expansive manufacturing base spans an impressive 10,000 square meters, offering a state-of-the-art environment for innovation and production excellence.

ISO CERTIFICATION
Boasting prestigious ISO certifications, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin exemplifies a commitment to superior quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

High Frequency Closed Circuit Cooling Tower for Optimal Performance
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Cutting-edge Closed Type Cooling Tower Series engineered for optimal performance.
· NSH/ NST Highly efficient Open Type Cooling Tower Series designed for diversified applications.
· NTG Robust Industrial Type Cooling Tower Series tailored for demanding environments.
· NECN/NECH Sophisticated Evaporative Condenser systems that deliver superior cooling efficiency.
· NWFL Innovative Dry Air Cooler solutions offering high-capacity, energy-efficient performance.

High Frequency Closed Circuit Cooling Tower for Optimal Performance
NEWIN provides a comprehensive inventory of premium cooling tower accessories, catering to maintenance and replacement demands across a variety of cooling tower sizes and types. Reach out to us to tailor the precise cooling tower accessories you require.

CONTAIN:
· Fan drive system components including fan, fan stack, reducer, motor, and shaft, expertly crafted to enhance functionality.
· Water distribution elements like nozzles and drift eliminators, designed for optimal fluid management.
· Heat exchange components such as PVC infills and cooling coils, ensuring efficient thermal transfer.
· Additional accessories including air inlet louvers and valves, meticulously engineered for seamless integration.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Experience seamless transit with our expertly coordinated shipping solutions, ensuring your equipment arrives on time and in pristine condition.

High Frequency Closed Circuit Cooling Tower for Optimal Performance
Closed Type Cooling Towers Shipment: Discover the assurance of secure and efficient delivery, with our meticulous handling process safeguarding your valuable assets throughout their journey.
High Frequency Closed Circuit Cooling Tower for Optimal Performance
High Frequency Closed Circuit Cooling Tower for Optimal Performance
Technical Strength& Standards

High Frequency Closed Circuit Cooling Tower for Optimal Performance
High Frequency Closed Circuit Cooling Tower for Optimal Performance

Certifications

High Frequency Closed Circuit Cooling Tower for Optimal PerformanceHigh Frequency Closed Circuit Cooling Tower for Optimal PerformanceHigh Frequency Closed Circuit Cooling Tower for Optimal PerformanceHigh Frequency Closed Circuit Cooling Tower for Optimal Performance

High Frequency Closed Circuit Cooling Tower for Optimal Performance

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier