High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling

Product Details
Customization: Available
Cooling Method: Mixed Flow
Ventilation Mode: Mechanical Ventilation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
  • High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
  • High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
  • High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
  • High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
  • High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Product Parameters
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWF Series
Material
Full Steel
Air Contact Form
Wet
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Cooling Capacity
1450kw
Fan Power
7.5*3kw
Spray Pump Power
5.5
Length
5600mm
Width
3250mm
Height
4950mm
Dry Weight
4150
Wet Weight
6800
Transport Package
Wood Packing, 20gp, 40gp Container Loading
Specification
Multi-cells is available
Trademark
NEWIN
Origin
China
HS Code
84195000
Production Capacity
500sets/Month

Product Description

Introducing the remarkable NEWIN NWF Series Mixed Flow Closed Type Cooling Tower, an epitome of advanced engineering and design.

NWF This exquisite series of closed cooling towers harnesses the power of cutting-edge composite flow cooling technology, ensuring unparalleled stability, remarkable energy savings, and a commitment to environmental sustainability. The elegantly designed system guides the spray water, once it has efficiently cooled the heat exchange coil, directly into the cold water basin through a meticulously crafted PVC heat exchange layer. This process not only effectively reduces the internal temperature of the tower but also significantly minimizes noise, as it prevents the disruptive impact of spray water directly falling into the bottom basin. Experience the seamless harmony of innovation and ecological responsibility with the NWF Series.

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
Product Description

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
High-Efficiency Mixed Flow Closed Circuit System

Operation
This state-of-the-art cooling tower features a fluid medium that efficiently travels through an advanced serpentine coil heat exchanger. An uninterrupted external spray system drenches the coil, optimizing cooling by facilitating heat exchange with spray water via a partition wall heat exchanger-creating a closed loop that ensures effective cooling. Low-temperature dry air enters the tower laterally, intersecting vertically with the spray water flow, achieving a dynamic composite heat transfer powered by high-performance fans. Once the air and water have fully exchanged heat, the high-temperature saturated air is expelled outside, while the spray water undergoes a secondary heat transfer through a specialized PVC heat exchange layer before descending into a water collection basin, removing excess heat and offering superior cooling efficiency.

Advantage
> The Mixed flow close-loop circulation system ensures the media remains pure, reduces maintenance costs, and is a stellar water-saving solution while providing exceptional cooling performance.
> The pairing of a stainless steel coil heat exchanger with a PVC heat exchange layer is both a marvel of efficiency and a tribute to elegant design. This cutting-edge configuration amplifies the heat transfer area, boosts heat exchange efficiency, and remarkably diminishes noise pollution.
> The innovative single-side air intake design reduces noise emissions at the rear of the tower, making it a perfect choice for noise-sensitive environments.
> The product boasts a compact structure with a space-saving design, enabling seamless integration of multiple cooling towers.
High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
Features

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
COOLING TOWER PARTS

1. Axial Flow Fan
The aluminum alloy axial flow fan operates with low noise, stability, and efficiency. The motor is equipped with a protection grade of IP55 and an insulation grade of F, ensuring heightened safety and reliability.

2. External Spray System
Spray cool water into heat exchange coil,continuously wets the surface of the coil for cooling.

3. Stainless Steel Heat Exchange Coil
Stainless steel coils exhibit superior heat exchange efficiency, enhanced corrosion resistance, light weight, prolonged equipment lifespan, and are environmentally sustainable due to their recyclability.

4. MAH PVC Fill Film ( PVC heat exchange layer)
The PVC filler heat exchange layer utilizes an integrated design of filler, air inlet grille, and drift eliminator to guarantee consistent air intake, significantly minimize water drift loss, and ensure optimal heat transfer performance. Furthermore, the unique surface texture provides ample heat exchange surface area, thereby enhancing overall efficiency. The filler could be upgraded to high-temperature materials to align with the specific working conditions of the project.

5. MBD PVC Drift Eliminator
The exclusive drift eliminatordesigned for closed cooling towers is adept at efficiently extracting airborne water droplets, boasting minimal wind resistance and an impressive capture rate of 99.99%, thus guaranteeing optimal heat transfer performance.

6. Air Inlet Louver
Ensure cool dry air evenly sucked in and passed through the coil and the PVC heat exchange layer, Limiting sun exposure and microbial growth.

7. Heavy-duty construction
The high-quality Z700 galvanized steel frame and shell,offering corrosion resistance. For particularly harsh environments, the optional SUS314/316 or NWN-Armour anti-corrosion coated steel provides exceptional protection.

8. Access Door
Into the tower inner maintenance platform through the access door. The presence of an inspection platform within the cooling tower enhances the convenience of conducting inspections and maintenance.

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
Product Parameters

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling

Design Conditions
 
NWF Dimension (mm) Weight (kg)
Model L W H Dry Wet
NWF-120-Z7-S 2300 1910 2850 843 1935
NWF-180-Z7-S 2300 1910 2930 883 2006
NWF-230-Z7-S 2850 2110 2930 1140 2701
NWF-290-Z7-S 3550 2110 2930 1377 3396
NWF-350-Z7-S 4150 2110 2930 1601 4013
NWF-450-Z7-S 4550 2250 3480 2055 4706
NWF-600-Z7-S 4550 2250 3720 2197 4899
NWF-750-Z7-S 5200 2250 4270 3201 6920
NWF-900-Z7-S 5200 2250 4490 3549 7535
NWF-1000-Z7-S 5200 2870 4490 4045 8589
NWF-1150-Z7-S 5900 2870 4540 4536 9677
NWF-1450-Z7-S 5900 3150 4690 5321 12230
NWF-1750-Z7-S 6500 3150 4690 5943 13744
NWF-2300-Z7-S 7500 3250 4900 6963 15214

Optional Various Additional Functions
Elevate performance with our sophisticated functions: Two-speed & VFD variable frequency motor for adaptable efficiency, Vibration Cut-off Switch for enhanced stability, and an Electronic descaler for maintenance ease. Our Water treatment equipment promises pristine quality, while the Anti-freeze automatic heating system ensures year-round operation. Experience tranquility with our noise reduction upgrade and the convenience of an External maintenance platform and guardrail. Simplify tasks with our Installation and maintenance boom, and much more.
 

Cost-effective Anti-Corrosion Solution
Unveil the future of anti-corrosion with NWN-Armour Anti-corrosion Technology.

Our products, coated with the revolutionary NWN-Armour anti-corrosion coating, boast exceptional resistance to corrosion, rivaling the superior attributes of stainless steel. This innovative technology offers a remarkably economical alternative to stainless steel, delivering unmatched value and longevity.
High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
Application

The High Capacity Mixed Flow Closed Type Cooling Tower from Newin (Guangdong) Machinery Co., Ltd. is an indispensable asset across a variety of industries, showcasing its versatility and reliability. It caters to the sophisticated requirements of the Energy industry, ensuring efficient cooling solutions. In the Pharmaceutical industry, it supports critical processes by maintaining optimal temperatures. It's a key player in the HVAC sector, providing robust performance for temperature regulation. The Chemical industry benefits from its precise cooling capabilities, while Machinery manufacturing sees enhanced operations due to its effectiveness. This exceptional cooling tower serves Metal processing and Plastic products industries with excellence, ensuring smooth production flows. In Industrial cooling contexts, its efficiency is unmatched, and it significantly contributes to Food processing, guaranteeing quality and safety through superior cooling.

 
High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
 
NEWIN Manufacturing Base

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
NEWIN FACTORY: Where advanced technology meets excellence.
Our state-of-the-art manufacturing base is strategically situated in Huizhou, Guangdong, sprawling over an impressive area of 10,000 square meters, designed for optimal efficiency and productivity.

ISO CERTIFICATION: A testament to our commitment to quality and sustainability.
We proudly hold the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, reflecting our dedication to superior quality and environmental stewardship.

WORKSHOPS: Dynamic spaces powering our production excellence.
Welding Workshop: Precision and strength in every weld.
Filler Thermoforming Workshop: Crafting essential components with precision.
Sheet Metal Processing Workshop: Shaping durability with precision engineering.
Cooling Tower Assembly Workshop: Assembling efficiency and reliability.

TESTING: Rigorous standards to ensure top-notch performance.
Independent Testing LAB: Uncompromising quality control and innovation.

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
NEWIN COOLING TOWERS: Revolutionizing cooling solutions for diverse needs.

· NWN/ NWF/ NCFN: A diverse range of Closed Type Cooling Tower Series for unmatched efficiency. Closed Type Cooling Tower Series: Engineered for high performance in closed environments.
· NSH/ NST: Innovative Open Type Cooling Tower Series for versatile applications. Open Type Cooling Tower Series: Designed for optimal cooling in open settings.
· NTG: High-efficiency Industrial Type Cooling Tower Series. Industrial Type Cooling Tower Series: Built for robust industrial demands.
· NECN/NECH: Advanced Evaporative condenser technology. Evaporative condenser: Cutting-edge solutions for efficient heat exchange.
· NWFL: State-of-the-art Dry Air Cooler for maximum cooling efficiency. Dry Air Cooler: Optimal cooling with exceptional reliability.

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
NEWIN is your ultimate partner in cooling solutions, manufacturing and stocking an extensive range of accessories to meet the maintenance and replacement needs of virtually any size and type of cooling tower. Contact us for customization to perfectly suit your requirements.

CONTAIN: Essential components for superior cooling tower performance.
· Fan drive system: Includes fan, fan stack, reducer, motor, shaft, and more for seamless operation.
· Water distribution: Features nozzles, drift eliminator, and other components for optimal water flow.
· Heat exchange: Incorporates PVC infills and cooling coil to enhance thermal performance.
· Other accessories: Such as air inlet louver and valves, ensuring comprehensive functionality.
 
Packaging & Shipping

Open type cooling towers shipment: Our high-performance open-type cooling towers are shipped with the utmost care. We ensure secure packaging and timely delivery, maintaining the integrity and efficiency of each unit.

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
Closed type cooling towers shipment: Experience worry-free shipping with our closed-type cooling towers. They are meticulously packaged to ensure no damage during transit, arriving ready for immediate installation and optimal performance.
High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
Technical Strength& Standards

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling
High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling

Certifications

High Capacity Mixed Flow Closed Type Cooling Tower for Water CoolingHigh Capacity Mixed Flow Closed Type Cooling Tower for Water CoolingHigh Capacity Mixed Flow Closed Type Cooling Tower for Water CoolingHigh Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling

High Capacity Mixed Flow Closed Type Cooling Tower for Water Cooling

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier