Industrial High Quality Round Water Cooling Tower

Cooling Method: Counter Flow
Ventilation Mode: Mechanical Ventilation
Material: FRP
Air Contact Form: Wet
Air Contact Way: Open
Tower Shape: Round
Customization:
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
NRT series
Noise Level
Ordinary
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Cooling Capacity
300 Ton
Brand Name
Newin
Warranty
1-2 Years
Transport Package
20/40gp/40hq Container Loading, Loose Packing
Specification
CTI
Trademark
NEWIN
Origin
China
HS Code
84195000
Production Capacity
15000 Sets/Year

Product Description

Industrial High Quality Round Water Cooling Tower

NRT series counter flow round type cooling towers were strictly examined by "Quality 
Supervision and Inspection Center of National Glass work" in 2006,  the result showed NRT series cooling towers completely comply with all national standards. NRT series counter flow induced draft cooling tower is designed with bottle type structure, so that the volume of prevailing air is minimized. Every part of the cooling tower is designed and made precisely and further permits easy installation and endurance due to light weight and strong structure. The testing report of cooling capacity proves its high efficiency. This series of cooling tower have passed the GB7190.1-1997 quality certification of super low noise.  


Design Features

Industrial High Quality Round Water Cooling Tower

NRT series counter flow induced draft cooling tower is designed with bottle type structure, So that the volume of prevailing air is minimized. Every part of the cooling tower is designed and made precisely and further permits easy installation and endurance due to light weight and strong structure. The testing report of cooling capacity proves its high efficiency.
Casing and Water Basin
Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers' special requirements.Fiberglass reinforced polyester(FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed. The surface is as smooth as mirror and could resist ultraviolet radiation. Also, it is colorfast and durable.
Axial Fan
All cooling tower fans with adjustable pitch blades are applied to being balanced, so that it can operate stably and quietly. Material chosen are A.B.S, aluminum alloy, stainless steel and F.R.P. 
Fan Drive
Small capacity cooling tower adopts direct drive low noise fan. Bigger capacity fan equipped with Belt drive speed reducer. Adjust belt tension through automatic spring to save the manual maintenance. Total enclosed structure can assure the low noise operation. This series of cooling tower have passed the GB7190.1-1997 quality certification of supper low noise. Further more the belt is durable without negative effect from water vapor and sunshine.
Water Distribution 
The using of high coefficient rotating sprinkler heads made of reinforced plastic or aluminum alloy can reduce the pressure of friction loss. Besides, the water can be distributed evenly to achieve the max thermal performance. 

Infill
Standard and low noise cooling tower are using high class thermal formed PVC sheet. The sheets are added with industrial plaits material and long fiberglass to slow the aging and increase the strength. Moreover the water film is thinner and longer so that the infill cabbage coefficient is higher. The infill is formed in the factory, instead of at construction site. To avoid uneven problem during installing. And it cold be easily cleaned and maintained in future. High temperature cooling tower is using P.P. Infill that could withstand up to 90 degree C water temperature. The surface of such infill is corrugated to increase the filling pitch to make sure that infill is clog-free and overcome the problem of water quality.
Steel Parts
All the steel parts and hard wares are made of hot dip galvanized steel(HDGS), so that the cooling tower is rust-free, durable and long service life. And the frame is stable and with good rigidity, the load is evenly distributed among each foundation, which makes operation and assembly easily.
Parts  Material  Remark
Water Basin  F.R.P Water-resistance resin and high quality fiberglass mat
 Casing  F.R.P Water-resistance resin and high quality fiberglass mat
 Motor  Cast Iron Fully enclosed anti water type, other brand motors for optional
 Motor support  Hot dip galvanized  steel  In accordance with BS EN ISO1461:1999 standard
 Fan  A.B.S Aluminum alloy material for optional 
 Infill  P.V.C  film For high temperature inlet water, UPVC and PP material for optional
 Air inlet screen    P.V.C   F.R.P  for optional
 Sprinkler head  A.B.S  Aluminum alloy material for optional
 Sprinkler pipe  P.V.C  For high temperature inlet water, hot-dip galvanized steel for optional
 Bolts & Nuts   Electroplated   Stainless steel 304, 316 for optional


Component Instructions
 
Frame: HDGS Hot-dip galvanized U-steel
Casing: F.R.P.
Water basin: F.R.P.
Distributing system: HDGS & PVC 
Fan: ABS or Aluminum alloy
Motor: fully enclosed waterproof type
Infill: PVC/PP
Connections: Flange
Industrial High Quality Round Water Cooling Tower
 



Standard of Design & Manufacture

Manufacturer's standard according to national standard GB7190.1-1997, installation, acceptance criteria, and mainly refer to the following national standards and industry standards. 
GB/T 1447-83 glass fiber reinforced plastic tensile performance test methods. 
GB/T 1448-83 glass fiber reinforced plastic bending performance test methods 
GB/T 1462-88 fiber reinforced plastic water imbibition test method. 
GB 2828-87 batch-by-batch inspection counter sampling procedures and sampling table. 
GB/T 3854-84 fiber reinforced plastic barcol hardness test method. 
GB/T 1033-86 plastic density and relative density test method. 
GB/T 1040-92 plastic tensile test method. 
GB/T 8237-87 glass fiber reinforced plastic (FRP) using liquid unsaturated polyester resin 
GB/T 2576-89 fiber reinforced plastic resin content unsolvable test method 
GB/T 2577-89 glass fiber reinforced plastic resin content test method. 
JC/T 278-94 in the alkali glass fiber roving. 
GB/T 8924-88 glass fiber reinforced plastic combustion performance test method of oxygen index method. 
GBJ 102-87 industrial circulating water cooling design specification. 
GB 50204-92 concrete structure engineering construction and acceptance specification.


Options

Dul-speed motor & VFD motor
Color of tower body: customized
Silencer blanket/silencer skirt
Wind inducer
Stainless steel bolts

F.R.P air inlet louver


Technical data
 
                 Item Nominal Dimension Motor Fan  Air  Flow  water  Weight 
  Flow  (mm)   (Kw) Diam. (cmm) pressure (kg)
  Model (m3/h) Diam.   Height      (mm)     (Kpa) Net  Run.  
  Max.           weight Weight
NRT-8 6.2 945 1380 0.18 525 70 13 42 180
NRT-10 7.8 945 1530 0.18 600 85 13 46 190
NRT-15 11.7 1195 1415 0.37 600 140 13 54 290
NRT-20 15.6 1195 1590 0.55 730 160 14 67 300
NRT-25 19.5 1400 1820 0.75 730 200 16 98 500
NRT-30 23.4 1650 1705 0.75 730 230 16 116 530
NRT-40 31.2 1650 1775 1.5 890 280 16 130 550
NRT-50 39.2 1830 1835 1.5 890 330 17 190 975
NRT-60 46.8 2145 1955 1.5 1150 420 17 240 1250
NRT-80 62.6 2145 2035 1.5 1150 450 18 260 1280
NRT-100 78.1 2900 2370 2.2 1410 700 21 500 1690
NRT-125 97.5 2900 2555 2.2 1410 830 23 540 1640
NRT-150 117 2900 2555 2.2 1410 950 23 580 1680
NRT-175 136.8 3310 3165 4 1750 1150 30 860 1960
NRT-200 156.2 3310 3165 4 1750 1250 30 880 1980
NRT-225 175.5 4120 3580 5.5 2100 1500 33 1050 2270
NRT-250 195.1 4120 3580 5.5 2100 1750 33 1080 2800
NRT-300 234 4730 3680 7.5 2400 2000 34 1760 3930
NRT-350 273.2 4730 3680 7.5 2400 2200 34 1800 3790
NRT-400 312.1 5600 3840 11 2745 2400 36 2840 5740
NRT-500 392.4 5600 3840 15 2745 2600 36 2900 5800
NRT-600 468 6600 4470 15 3400 3750 42 3950 9350
NRT-700 547.2 6600 4470 18.5 3400 3750 42 4050 9450
NRT-800 626.4 7600 4720 22 3700 5000 45 4700 11900
NRT-1000 781.2 7600 4720 22 3700 5400 45 4900 12100


Application

Cooling tower is mainly used in air conditioning cooling system, frozen industry, injection molding, tanning, foaming, electricity, steam turbine, aluminum processing, air compressors, industrial water cooling, etc. Those industries could be divided into 4 categories as follows:

♦ Air temperature adjust : air conditioning, refrigerator, freezer, refrigeration, air conditioning, etc.;
♦ Manufacturing and processing: the food industry, pharmaceutical industry, metal casting, plastic industry, rubber industry, textile industry, steel mills, chemical industry, petrochemical products, etc.;
♦ Cooling the running machines: mechanical operation of the generator, steam turbine, air compressor, hydraulic press, engine, etc.;
♦ other industries...

Below is some round type cooling towers' project in different industries.

Shipping

Industrial High Quality Round Water Cooling Tower

FRQ:
1. Are you manufacturer?
Answer: Yes we are a cooling tower manufacturer located in Guangdong Province China. With 18 years of manufacturing and OEM service for several brand of famous cooling tower.
2. Can you provide the cooling tower parts different with the specification in above showing form?
Answer: We can manufacturer and newly design for special order based on your provided specification and drawing or performance requirements.
3. What products are you manufacturing?
Answer: Cooling towers with its accessories (motor, steel frame, plastic components, FRP panel, PVC infill, motor, water pump, motor fan, control box for fan)
4. What is the delivery time?
Answer: For round type cooling tower below 300RT, we have stock in warehouse. Other type cooling tower, need to production upon receive the PO. Leading time 15 working days.
5. What is your quality warranty?
Answer: 1 year for motor, 2 years for steel parts, 5 years for FRP pannel. Free parts available during garrantee peroid.
6. How many workers working in your factory?
Answer: 270 workers at the end of 2013.
7. Do you have any production management system or certification for products.
Answer: ISO 9001: 2008 quality and environment management system certificates. CTI certificate for cooling towers.




Industrial High Quality Round Water Cooling Tower

For cooling tower information please visit to newinmachine.en.made-in-china.com
For cooling tower parts information please visit to newinmachine.en.made-in-china.com


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
OEM/ODM Availability
Yes