High-Capacity Dry Air Cooler for Innovative Cooling Solutions
NWFL-V The NWFL-V series represents a remarkable leap forward in the realm of high-performance cooling technology, featuring a V-type dry air cooler ingeniously engineered with a state-of-the-art Free Cooling System. This system ensures extraordinary cooling efficiency, making it exceptionally well-suited for HVAC systems and a myriad of other facilities. A standout feature is its non-water consumption, offering a sustainable and cost-effective alternative to traditional evaporative cooling methods.
Features
· Ingenious V-type design coupled with an outstanding Free cooling system,
Ensuring unparalleled cooling efficiency while remarkably conserving water resources with zero consumption.
· Incorporation of optimally efficient components, such as the advanced EC motor,
Guaranteeing maximum system efficiency and significant energy savings.
· Substantial redundancy incorporated,
Effectively eliminating any potential thermal performance losses.
· Exceptional reliability paired with straightforward and hassle-free maintenance.
Working Principle

When the remarkable NWFL-V adiabatic cooler is set into action:
The advanced EC fan system initiates the process by drawing in the refreshingly cool and dry air. This air is then guided into the tower through our meticulously designed V-shaped finned tube heat exchanger. The innovative and large-contact-surface V-shaped construction greatly enhances the cooling dynamics, swiftly accelerating the cooling of both the air and the hot process fluid. This design brilliantly boosts heat exchange efficiency. Once the air has engaged in thorough partition wall heat exchange with the cool, dry air, the now hot and saturated air is efficiently expelled from the tower. The result is the achievement of unparalleled Free Cooling, utilizing non-evaporative cooling methods, to create an exceptionally efficient cooling solution.
Series |
Type |
Capacity |
1. Fan Drive System |
2. Heat Exchange System |
NWFL-V |
V |
Range |
EC axial fans |
Finned coil |
Maximum thermal performance |
207~936kw |
Intelligent frequency conversion,
more energy saving |
Maximum heat transfer surface |
Free cooling
system |
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption. |
Application |
Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc. |
Parameter
Model |
Cooling Capacity |
Total Dimension |
Fan |
Weight |
L |
W |
H |
Nos of Fans |
Noise Level |
Power |
Shipping |
Operation |
kw |
mm |
mm |
mm |
Nos |
dB(A) |
kw |
kg |
kg |
NWFL-231-4D10-800V |
200 |
2740 |
2050 |
2190 |
4 |
79.4 |
3.14 |
1187 |
1386 |
NWFL-231-6D10-800V |
250 |
2740 |
2050 |
2190 |
4 |
82.7 |
3.76 |
1332 |
1586 |
NWFL-231-8D10-800V |
290 |
2740 |
2050 |
2190 |
4 |
87.8 |
4.89 |
1477 |
1786 |
NWFL-241-4D10-800V |
255 |
2740 |
2050 |
2550 |
4 |
80 |
4.43 |
1329 |
1590 |
NWFL-241-6D10-800V |
315 |
2740 |
2050 |
2550 |
4 |
81.8 |
5.47 |
1522 |
1854 |
NWFL-241-8D10-800V |
360 |
2740 |
2050 |
2550 |
4 |
84.5 |
6.49 |
1714 |
2119 |
NWFL-251-4D10-800V |
310 |
2740 |
2050 |
2980 |
4 |
81.5 |
6.44 |
1493 |
1817 |
NWFL-251-6D10-800V |
400 |
2740 |
2050 |
2980 |
4 |
83 |
7.61 |
1732 |
2146 |
NWFL-251-8D10-800V |
450 |
2740 |
2050 |
2980 |
4 |
85 |
8.81 |
1971 |
2475 |
NWFL-261-4D10-900V |
375 |
2740 |
2250 |
3300 |
4 |
80.8 |
7.37 |
1675 |
2060 |
NWFL-261-6D10-900V |
470 |
2740 |
2250 |
3300 |
4 |
84.9 |
8.35 |
1961 |
2453 |
NWFL-261-8D10-900V |
535 |
2740 |
2250 |
3300 |
4 |
86.4 |
9.75 |
2247 |
2847 |
Note:
1. Standard design working condition- Fluid in/out Temp. Difference: 5ºC.
2. Standard design ambient temperature- Temp. Approach: 15ºC.
3. Thermal design based on pure water.
4. Please contact NEWIN sales representative if the working condition is different from the above standard design condition.
Components& Options
· Heavy-duty Construction
The galvanized steel panel, fortified with our advanced NEWIN Armour anti-corrosion coating, offers formidable resistance and durability similar to stainless steel. This ensures the equipment performs optimally with elevated concentration cycles, significantly minimizing water usage. Furthermore, any damage to the coating is effortlessly repairable, ensuring prolonged and efficient service.
· V Type Finned Coil Heat Exchanger
Crafted with precision, our finned coil heat exchanger utilizes expertly spaced copper tubes and aluminum fins, maximizing thermal performance. The tubes are securely brazed to the coil headers and flared to the finned coil, assuring exceptional thermal conduction and performance under various conditions.
· EC Axial Fan
- Our EC motor, featuring a straight-shaft drive, is engineered for resilience with an IP55 protection grade and F insulation level. It excels in continuous operation under extreme heat and humidity, maintaining smooth operation and superior energy efficiency that meets or exceeds IE4 standards.
- With durable tapered roller bearings, our fans promise remarkable load capacity and an outstanding lifespan exceeding 20,000 hours, guaranteeing sustained high performance and longevity.
- Through meticulous static and dynamic testing, noise levels are significantly reduced without compromising heat exchange effectiveness. The integration of PFC technology keeps harmonics under control at below 35%, ensuring the EC fan system retains high static efficiency even at lower speeds.
· Adiabatic Intelligent Controls
- The intelligent EC fans effortlessly adapt with frequency conversion to accommodate diverse operational conditions on site, driving heightened energy savings.
- Provides dry operation capability when water usage is restricted, ensuring versatile functionality.
· Options
- Enhance the coil's resistance capacity to fortify against challenging operational demands.
- Safeguard against coil freeze-ups, ensuring reliable operation in extreme conditions.
- Opt for a low noise upgrade to create a quieter operational environment.
- Increase system redundancy to bolster reliability and operational security.
NEWIN Manufacturing Base

NEWIN FACTORY
Nestled within the vibrant locale of Huizhou, Guangdong, our expansive manufacturing base spreads across a remarkable 10,000 square meters. This state-of-the-art environment fosters innovation and showcases our commitment to production excellence.
ISO CERTIFICATION
Proudly boasting prestigious ISO certifications such as ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin stands as a beacon of dedication to outstanding quality and sustainable practices.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Dedicated Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Discover our cutting-edge Closed Type Cooling Tower Series, meticulously engineered for optimal performance and reliability.
·
NSH/ NST Introducing the highly efficient Open Type Cooling Tower Series, expertly designed for a wide array of applications.
·
NTG Our robust Industrial Type Cooling Tower Series is tailored to thrive in the most demanding environments.
·
NECN/NECH Explore our sophisticated Evaporative Condenser systems, delivering unparalleled cooling efficiency.
·
NWFL Our Innovative Dry Air Cooler solutions offer high-capacity, energy-efficient performance, setting a new standard in cooling technology.
NEWIN offers an extensive inventory of premium cooling tower accessories, fulfilling maintenance and replacement needs for various sizes and types. Contact us to customize the precise cooling tower accessories tailored to your requirements.
CONTAIN:
· Fan drive system components, including fan, fan stack, reducer, motor, and shaft, are expertly crafted to enhance performance and function.
· Water distribution elements such as nozzles and drift eliminators are designed for optimal fluid management and efficiency.
· Heat exchange components like PVC infills and cooling coils ensure efficient thermal transfer, maximizing cooling performance.
· Additional accessories, including air inlet louvers and valves, are meticulously engineered for seamless integration and superior performance.
Packaging & Shipping
Open Type Cooling Towers Shipment: Embark on a worry-free shipping journey with our meticulously organized logistics services. We guarantee punctual delivery and maintain the immaculate condition of your equipment from our facilities to your doorstep.
Closed Type Cooling Towers Shipment: Enjoy peace of mind with our secure, reliable delivery service. Our detailed and careful handling ensures the utmost protection of your precious assets, guaranteeing they reach you in perfect condition every time.
Technical Strength& Standards


Certifications