Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
  • Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
  • Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
  • Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
  • Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
  • Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
Find Similar Products
  • Overview
  • Features
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NBR
Condition
New
Hardness
Hardened Tooth Surface
Installation
90 Degree
Layout
Coaxial
Gear Shape
Conical - Cylindrical Gear
Step
Four-Step
Type
Gear Reducer
Application
Cooling Tower
Transport Package
Wooden Case
Trademark
NEWIN
Origin
China
HS Code
8419500090
Production Capacity
1000000mt Per Year

Product Description

High Quality Cooling Tower Belt Pulley Reducer

NBR & NSR The belt type reduction drive is an exceptional choice for a wide range of applications. It excels in power transfer between the driving and driven wheel pulleys, thanks to the tension in the belt. This mechanical transmission offers a host of advantages: a straightforward design, stable power transfer, and excellent vibration absorption capabilities. It enables power transmission over large axial distances between shafts, is cost-effective, requires no lubrication, and is easy to maintain. This makes it an ideal solution for cooling towers and various other mechanical equipment.

The comprehensive belt drive system is composed of a motor pulley, a fan pulley, and durable V belts. Available in two versatile types—upright mounting and upside-down mounting—this system adeptly meets the diverse requirements of different cooling tower configurations.
Reliable Cooling Tower Pulley Belt Reducer for Enhanced EfficiencyReliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency

Features

Crafted with meticulous precision, our Reliable Cooling Tower Pulley Belt Reducer showcases an exceptional belt sourced from a renowned manufacturer. This premium belt boasts impressive elasticity, offering users the flexibility to select the desired length within a specific range. This adaptability ensures seamless adjustment to varying center distance requirements, catering perfectly to more expansive operational environments.

The belt pulley reducer is ingeniously designed, featuring a straightforward yet robust structure that guarantees stable operation. Experience minimal vibration and whisper-quiet functionality, all while benefiting from an extended service life, making it a quintessential choice for efficiency-driven applications.
Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency

Drive type Drive efficiency Main components Maintenance Note.
Belt 90~95% Belt, motor pulley, fan pulley, big bearing Check belt tightness to prevent slipping.
Belt damaged need to be replaced.
Low installation requirement that it just need to keep the belt level.
Product Parameters

Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency

Model Nos.of
Groove
H H1 H2 H3 Ø1 Ø2 Ø3 Ø4 N-ØD K T
NBR-5 2 45 50 175 76 355 300 263 34 4-Ø13 37 8
NBR-6 3 65 60 225 105 456 348 300 38 4-Ø14 41 8
NBR-8 4 85 62 265 120 456 428 390 50 6-Ø16 53 12
NBR-10 4 85 62 310 135 608 500 450 50 4-Ø16 53 12
NBR-12 5 105 62 310 143 660 500 450 60 4-Ø16 63 12
NBR-14 6 125 62 320 153 660 500 450 75 6-Ø16 79.5 20
Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
Model Nos.of
Groove
H H1 H2 H3 Ø1 Ø2 Ø3 Ø4 N-ØD K T
NSR-8 4 85 55 420 105 430 580 540 38 4-Ø14 41 8
NSR-10 4 85 55 480 117 430 580 540 50 4-Ø14 53 12
NSR-12 4 85 205 700 133 608 730 688 50 4-Ø16 53 12
NSR-14 5 105 205 700 143 660 765 720 60 4-Ø18 63 12
NSR-16 8 165 205 800 153 660 765 720 75 4-Ø18 79.5 20
NEWIN Manufacturing Base

Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
The renowned NEWIN FACTORY: A hallmark of innovation and quality.
Situated in the vibrant hub of Huizhou, Guangdong, our expansive manufacturing base sprawls across an impressive 10,000 square meters, embodying our commitment to excellence.

ISO CERTIFICATION: A testament to our unwavering quality standards.
Proud recipients of the ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, underscoring our dedication to superior quality and environmental stewardship.

WORKSHOPS: The heart of our manufacturing prowess.
Welding Workshop: Where precision meets craftsmanship.
Filler Thermoforming Workshop: A fusion of innovation and technology.
Sheet Metal Processing Workshop: Crafting excellence with every curve and angle.
Cooling Tower Assembly Workshop: The birthplace of cooling innovation.

TESTING: Ensuring the pinnacle of performance and reliability.
Our Independent Testing LAB: Setting benchmarks in quality assurance.

Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
NEWIN COOLING TOWERS: Where performance meets perfection.

· NWN/ NWF/ NCFN: The elite Closed Type Cooling Tower Series. Closed Type Cooling Tower Series: Engineered for optimal efficiency.
· NSH/ NST: Leaders in the Open Type Cooling Tower Series. Open Type Cooling Tower Series: Open to unrivaled performance.
· NTG: Pioneering the Industrial Type Cooling Tower Series. Industrial Type Cooling Tower Series: Built for industrial excellence.
· NECN/NECH: Innovators in Evaporative Condenser technology. Evaporative condenser: Elevating condensation efficiency.
· NWFL: Masters of Dry Air Cooler innovation. Dry Air Cooler: Delivering the pinnacle of air cooling solutions.

Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
At NEWIN, we take pride in our extensive range of cooling tower accessories, designed to meet the diverse maintenance and replacement needs of cooling towers of nearly any size and type. Reach out to us for tailored accessory solutions crafted just for you.

CONTAIN: Comprehensive solutions for all cooling needs.
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.): Precision-engineered for unparalleled performance.
· Water distribution (nozzles/ drift eliminator etc.): Efficiency in flow management.
· Heat exchange(PVC infills/ cooling coil etc.): Optimizing thermal performance.
· Other accessories (air inlet louver/ valve etc.): Enhancing functionality and efficiency.
Packaging & Shipping

Open Type Cooling Towers Shipment: Delivering our innovative solutions to you is our priority. Our open-type cooling towers are swiftly and securely shipped, ensuring prompt delivery and minimal downtime for your operations. Trust in our reliable logistics to bring you the efficiency-enhancing capabilities of our Reliable Cooling Tower Pulley Belt Reducer, wherever you are located.

Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
Closed Type Cooling Towers Shipment: We pride ourselves on our comprehensive logistics network, ensuring that our closed type cooling towers reach you in an expedited manner. Every shipment is handled with care to preserve the integrity and performance of each Reliable Cooling Tower Pulley Belt Reducer, allowing you to benefit from enhanced efficiency at the earliest opportunity.
Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
Technical Strength& Standards

Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency
Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency

Certifications

Reliable Cooling Tower Pulley Belt Reducer for Enhanced EfficiencyReliable Cooling Tower Pulley Belt Reducer for Enhanced EfficiencyReliable Cooling Tower Pulley Belt Reducer for Enhanced EfficiencyReliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency

Reliable Cooling Tower Pulley Belt Reducer for Enhanced Efficiency


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More