Introducing the Newin Cellular Type Drift Eliminator, an advanced solution designed for unparalleled efficiency. Also known as the PVC Drift Eliminator or simply the Drift Eliminator for Cooling Towers, this product is engineered to significantly enhance the performance of cooling systems. Count on Newin (Guangdong) Machinery Co., Ltd. to deliver exceptional quality and innovation with our PP Drift Eliminator, ensuring optimal wet and dry air contact for your cooling needs.
Product Description
BAD Newin BAThe D Celluar Drift Eliminator by Newin (Guangdong) Machinery Co., Ltd. is expertly engineered to efficiently remove small water droplets from exhaust air, mitigating potential nuisances and health concerns. Without intervention, these droplets could escape through the tower's top with heated air. Our BAD series drift eliminators are crafted with precision to guide the air stream through a complex path. This intricate design ensures water droplets are redirected, striking the drift eliminator's side walls to coalesce and flow back into the cooling tower's wet section, optimizing both safety and efficiency.
FEATURES
- Resilient to aging, the drift eliminators boast superior water absorption capabilities for enhanced performance.
- Featuring low airflow resistance and exceptional strength, they deliver robust and efficient operation.
- Designed for straightforward installation and extended service life, offering long-term reliability.
- Versatile enough to serve as a replacement for air inlet louvers, adapting to various system requirements.
Parameter
PROPERTIES
At Newin (Guangdong) Machinery Co., Ltd., we understand the critical role of precision in drift eliminators. Whether you require specific adjustments in length, width, materials, or thickness, our bespoke solutions are designed to meet your exact specifications. Share your detailed requirements with us, and we will provide you with the optimal solution and a competitive offer. Catering to specific needs, we also offer fill media in flame-retardant or anti-bacterial versions upon request, ensuring we can meet your every demand.
Module Length (Max) |
mm |
2440 |
Module Width (Max) |
mm |
500 |
Module Height |
mm |
140 |
Flute Height |
mm |
25 |
Sheet Thickness - Before Forming |
mm |
0.45 |
Sheet Thickness - After Forming |
mm |
0.38 |
Max. application temp. (short time) - PVC |
°C |
60 |
Customized size and thickness available for special request. Contact Newin for details. |
STRUCTURE & INSTALLATION DRAWING
Newin is committed to delivering excellence not just in products but also in service. We provide comprehensive structure and installation drawing advice, alongside jobsite storage guidance and a quality control report shipped with your order. This ensures that you are prepared and informed upon receipt of the materials. We also offer OEM services and the opportunity for special mold designs tailored to your unique requirements. Trust Newin to enhance your project with precision and care every step of the way.

Application
APPLICATION & USAGE
The Newin BAD cellular drift eliminator stands as a premier choice for those seeking to replace BAC components. This advanced product ensures seamless integration into existing systems, optimizing overall performance. Designed specifically for cooling towers, each component undergoes rigorous SGS testing in compliance with ASTM Standards, assuring unparalleled quality. This guarantees the highest efficiency for your cooling towers. Simply provide us with your tower model or dimensions, and we will expertly calculate the number of sheets required for a successful replacement.

APPLICABLE COMMERCIAL STANDARDS
Our sheets adhere strictly to SGS testing standards in accordance with ASTM protocols. We ensure each property, among many, is meticulously tested. Upon request, our products can undergo comprehensive evaluations to meet your specifications.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
FILED DATA FOR CELLUAR DRIFT ELIMINATOR REPLACEMENT
For precise maintenance or repair projects involving cooling towers, input the required measurements below. Trust in Newin (Guangdong) Machinery Co., Ltd. for excellence and dependability. We offer on-site evaluations and maintenance services tailored to fit cooling tower fills and components with expert engineering precision.
NEWIN Manufacturing Base

NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements.
ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for excellence.
WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop
TESTING
Dedicated Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model embodies the cutting-edge of cooling tower technology.
·
NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
·
NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
·
NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
·
NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.
CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping
Open type cooling towers shipment: Our meticulously engineered open-type cooling towers are expertly packaged, guaranteeing they reach you in immaculate condition. We prioritize the utmost safety and security, employing premium materials and strategic packing techniques to provide an impregnable shield against any potential transit damages. Revel in seamless logistics and prompt delivery, ensuring that your cooling solutions become operational without delay for maximum efficiency and performance.
Closed type cooling towers shipment: Experience peace of mind with our robust packaging solutions for closed-type cooling towers. Each unit is meticulously encased to endure the rigors of transport, ensuring arrival at your site in pristine condition and ready to deliver top-tier performance. Our steadfast dedication to quality control and punctual shipping empowers you to concentrate on what truly matters - harnessing our cutting-edge cooling technology to enhance your applications and achieve unparalleled outcomes.
Technical Strength& Standards


Certifications