New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory

Product Details
Customization: Available
Cooling Method: Cross Flow
Ventilation Mode: Mechanical Ventilation
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
  • New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
  • New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
  • New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
  • New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
  • New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
Find Similar Products

Basic Info.

Model NO.
NST-600
Material
FRP
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, ISO, CTI
Condition
New
Nominal Flow
600 M3/H
Motor Power
7.5*3 Kw
Fan Diameter
2400 Mm
Net Weight
4560 Kg
Running Weight
12500 Kg
Water Pressure
42 Kpa
Transport Package
20/40/40hq Container with Loose Packing
Specification
customized
Trademark
NEWIN
Origin
China
HS Code
841950
Production Capacity
15000 Sets / Year

Product Description

New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory

New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
NST series cross flow square  cooling tower is available in capacity for single cell from 100 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements.This cooling tower is highly used in heating, ventilation, air-conditioning, and light to medium processing applications.

New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory

Features

♦ Thermal isolated  casing, Stainless steel 304 /316L material
♦ Prevents external heat into the tower and insulation, damps the vibration
♦ Resistant to acid and alkali, effectively eliminate the oxidation on the surface of the galvanized
♦ Modular design, high strength, good rigidity, nice appearance
♦ Factory assembled, easy installation and maintenance 

New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory


Space Saving, Light-duty Structures
Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly.


Energy Saving, Low Noise
Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Double speed motor for optional to power saving according to customers' special requirements.
Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). 


Good Corrosion Resistance
Tower casing, tank and panel are made up of high corrosion resistance performance FRP material, and Galvanized steel structure improves the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life.

Convenient combination and Easy Maintenance
Combinations can be used to meet the requirements of different working condition.If limited space in end user, we can also design for the special cooling tower to meet users' requirements for the performance of thermal and noise.


New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory

Components Instruction

Motor                                                                                            
Fully enclosed type, with protection grade: IP55,   and insulation class:  F.  Smooth operation, low failure rate. Options: Siemens, ABB motor, etc.

Fan and Reducer
Adopting low speed, big chord length and width of blade fan, with characteristic of stable wind speed, low noise, few eddy current and high efficiency, etc. Enough air flow can be easily get at low rotating speed of the fan, what's more, the cooling tower fan blade angle can also be adjusted according to different climate condition, therefore, the cooling tower can not only be ensured in the rough conditions but meet the operation requirements of users.

Infill 
Brand new PVC infill is vacuum formed of 0.3 thickness or more thicker PVC film with excellent chemical and high distortion resistance, big coefficient of heat transfer, small wind resistance, high ventilation performance. 
We have different materials to suit different water temperature. What's more, the PVC filler's compact package design is convenient to take out for cleaning, and the special designed configuration of the filling incorporates the function of drift eliminator, louver and wet deck surface.

Steel Structure 
Hop-dip galvanized steel framework to keep the cooling tower great performance and long lifespan, good anti-corrosion, guarantee the use of more than 15 years. Stainless steel hardware parts are also available for options if somewhere special condition needed.

Distribution System
Hot water distribution system is used F.R.P parts, non-corrosive and long life, and are specially designed for uniform distributing and ease of inspection. A distribution cover is attached on top to prevent    water from splashing out and other dirt to come into the water.   

Inspection Door
Inspection doors are used to provide a convenient access to the interior for inspection, maintenance, adjustment of the internal parts, like float valve, cleaning up the lift-out strainer and flushing of the water basin.
 
Parts  Material  Remark
Water Basin  F.R.P Water-resistance resin and high quality fiberglass mat
 Casing  F.R.P Water-resistance resin and high quality fiberglass mat
 Motor  Cast Iron Fully enclosed anti water type(TEFC), other brand motors for optional
 Motor support  Hot dip galvanized  steel  In accordance with BS EN ISO1461:1999 standard
 Fan  A.B.S Aluminum alloy material multi-blades low fan
 Driven system   Hot dip galvanized steel  Belts and pulley or Gear reducer
 Infill  P.V.C  film Hanging up type film fill with integrated drift eliminator, UPC, PP material as optional
 Flame work    Hot dip galvanized steel   Stainless steel 304, 316 for optional
 Water distributing system  F.R.P.  Top water distributing water basing
 Eliminator  P.V.C  PVC blade type eliminators e
 Bolts & Nuts   Electroplated   Stainless steel 304, 316 for optional

Technical Parameters of NST Series Cross Flow Cooling Towers
 
         Item Dimension (mm)  Fan Water Inlet  Water Outlet Weight (kg)
 Model Length Width Height Diameter
 (mm)
Motor 
(Kw)
(DN) (DN) Dry Wet
NST-19-A16-3A12-C1 1900 3800 3680 1600 3.0 100*2 125 1250 2650 
NST-22-B16-3A12-C1 2200 3800 3680 1600 4.0 125*2 150 1350 2750 
NST-22-B18-3A14-C1 2200 4010 4080 1800 4.0 125*2 150 1450 2950 
NST-26-C22-3A14-C1 2600 4420 4080 2200 5.5 125*2 200 1550 3250 
NST-26-C22-3A15-C1 2600 4420 4280 2200 5.5 150*2 200 1720 3530 
NST-26-D22-3A16-C1 2600 4420 4480 2200 5.5 150*2 200 1820 4170 
NST-30-D24-3A16-C1 3000 4620 4680 2400 7.5 150*2 250 2280 4700 
NST-30-D24-4A14-C1 3000 5230 4280 2400 7.5 150*2 250 2620 5470 
NST-30-E24-4A16-C1 3000 5230 4680 2400 11 150*2 250 2750 5700 
NST-33-E28-4B18-C1 3300 5640 5130 2800 11 150*4 300 3050 6600 
NST-33-F28-4B20-C1 3300 5640 5530 2800 15 150*4 300 3450 7000 
NST-38-F28-4B20-C1 3800 5640 5530 2800 15 150*4 300 3750 7800 
NST-38-F34-4B20-C1 3800 6240 5630 3400 18.5 150*4 350 4250 8600 
NST-46-G34-4B20-C1 4600 6240 5630 3400 18.5 150*4 350 4850 10200 
NST-46-G36-4B22-C1 4600 6450 6030 3600 30 150*4 350 5250 14500 
NST-51-I36-4B22-C1 5100 6450 6080 3600 30 200*4 400 5650 15500 
NST-53-J42-4B24-C1 5300 7060 6530 4200 30 200*4 400 6450 17800
NST-53-J42-4B26-C1 5300 7440 6930 4200 30 200*4 400 7150 19500 


Factory 

New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
Cooling Tower Shipment

New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory

NEWIN COOLING TOWER

New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory
New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory


New 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic FactoryNew 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic FactoryNew 600 Ton FRP Square Type Cross Flow Cooling Tower for Plastic Factory

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier