High Quality Spindle Cross Cooling Tower Fills/Infill

Product Details
Customization: Available
Cooling Method: Cross Flow, Cooling Tower
Certification: ISO, CE, ISO, SGS

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • High Quality Spindle Cross Cooling Tower Fills/Infill
  • High Quality Spindle Cross Cooling Tower Fills/Infill
  • High Quality Spindle Cross Cooling Tower Fills/Infill
  • High Quality Spindle Cross Cooling Tower Fills/Infill
  • High Quality Spindle Cross Cooling Tower Fills/Infill
  • High Quality Spindle Cross Cooling Tower Fills/Infill
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
SPH
Condition
New
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet
Air Contact Way
Open
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Material
PVC or UPVC
Transport Package
20/40/40hq Container with Loose Packing
Specification
850 X 1000 mm, 1000 X 1000 mm
Trademark
NEWIN
Origin
China
HS Code
3926901000
Production Capacity
1000000

Product Description

High Quality Cross Cooling Tower Fills/Infill
SPH Cross Flow Film Fill :
High Quality Spindle Cross Cooling Tower Fills/Infill

Product Description

SPH  Newin SPH series fill is used for cross flow cooling tower, cooling tower PVC sheet filler with the advanced technical, long lifetime, low resistance, light weight. During the service, the fill can increase the water flow process. Fully solve gas-liquid exchange, reasonable design, not easy to hide dirt, easy to install.It is widely used in Square cooling tower.
 


FEATURES

-Applicable for cross flow square type cooling towers
-Using modified PVC sheet, unique modified formula makes the infill strong resistance and high durability.
-Vac form special processing, the inner side (fan side) edge with integrated liquid baffle plate, and controls the drift loss of water in minimum value. and maximize the heat exchange performance of the water and air.
-Standard heat temperature of 50 ° C, heatproof specification (optional) can use up to 80 ° C.
Parameter

PROPERTIES 

With different request in SPH film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Length (Max)  mm 1000
Module Width   mm 850/1000
Module Depth   mm -
Flute Height  mm 16
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 176
Sheet Thickness - Before Forming  mm 0.32
Sheet Thickness - After  Forming  mm 0.28
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.
 



STRUCTURE & INSTALLATION DRAWING

Newin supply structure & installation drawing advice with jobsite storage advice and quality control report along with shipment to make attention to customers when they receive the materials. OEM or special mold design also available on request.High Quality Spindle Cross Cooling Tower Fills/Infill

 

Application

APPLICATION & USAGE 

Newin SPH Film Fill with SGS test in ASTM Standards to keep high quality infill to get the high efficiency of the cooling tower. Inform us the tower model or size, we will estimate the Nos of sheets needed for your cooling tower replacing.
High Quality Spindle Cross Cooling Tower Fills/Infill



Applicable Commercial Standards

Sheets material is strictly followed below SGS test with ASTM standards. Each property or all properties as below tested by your products are also vailable on request.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material.




FILED DATA FOR CROSS FLOW FILM FILL REPLACEMENT

Fill in below measurements data for your maintenance cooling tower or reparing projects demand quality and reliability, count on Newin, site visit or maintenance service, engineered to fit the cooling tower fills or components. 
High Quality Spindle Cross Cooling Tower Fills/Infill
Options

Explore More Products You May Be Interested In:

High Quality Spindle Cross Cooling Tower Fills/Infill
High Quality Spindle Cross Cooling Tower Fills/Infill

High Quality Spindle Cross Cooling Tower Fills/Infill
NEWIN Manufacturing Base

High Quality Spindle Cross Cooling Tower Fills/Infill
NEWIN FACTORY
Embark on an awe-inspiring journey to our state-of-the-art manufacturing base, strategically nestled within the vibrant industrial hub of Huizhou, Guangdong. This expansive 10,000 square meter facility stands as a beacon of innovation and excellence, constantly setting new standards within the industry.

ISO CERTIFICATION
Our steadfast commitment to unparalleled quality and environmental stewardship is proudly underscored by our esteemed ISO certifications: ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, highlighting our unwavering dedication to excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

High Quality Spindle Cross Cooling Tower Fills/Infill
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unmatched cooling tower efficiency with our Closed Type Cooling Tower Series, meticulously crafted to offer superior performance and reliability for a wide array of industrial applications.
· NSH/ NST Discover the steadfast reliability and robust performance of our Open Type Cooling Tower Series, expertly engineered for optimal operation across diverse environments.
· NTG Explore the remarkable capabilities and industrial-strength engineering of our Industrial Type Cooling Tower Series, specifically crafted for the most demanding applications.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new benchmarks for performance in the industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, redefining the possibilities in cooling solutions.

High Quality Spindle Cross Cooling Tower Fills/Infill
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of premium accessories to cater to all your maintenance and replacement needs across various cooling tower sizes and types. Reach out to us to customize the perfect suite of accessories tailored to your specific cooling tower requirements.

CONTAIN:
· A robust Fan drive system, intricately designed to include a fan, fan stack, reducer, motor, and shaft, all engineered for optimal performance.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and drift eliminators for superior effectiveness.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, designed for peak performance.
· Additional essential accessories, including sophisticated air inlet louvers and valves, to seamlessly complete your system.
 
Packaging & Shipping

Open type cooling towers shipment: Our impeccably crafted open-type cooling towers are securely packaged to ensure pristine arrival at your destination. We utilize top-tier materials and sophisticated packing techniques to prevent any transit mishaps. Committed to flawless logistics and punctual delivery, our cooling solutions are primed for immediate operation, delivering reliability and efficiency from the very start.

High Quality Spindle Cross Cooling Tower Fills/Infill
Closed type cooling towers shipment: Experience unparalleled assurance with our comprehensive packaging solutions for closed-type cooling towers. Each tower is meticulously protected to endure the demands of transit, guaranteeing their arrival in impeccable condition, ready to deliver peak performance. Our steadfast focus on quality control and prompt shipping enables you to concentrate on maximizing the potential of our cutting-edge cooling technology in your operations.
High Quality Spindle Cross Cooling Tower Fills/Infill
High Quality Spindle Cross Cooling Tower Fills/Infill
Technical Strength& Standards

High Quality Spindle Cross Cooling Tower Fills/Infill
High Quality Spindle Cross Cooling Tower Fills/Infill

Certifications

High Quality Spindle Cross Cooling Tower Fills/InfillHigh Quality Spindle Cross Cooling Tower Fills/InfillHigh Quality Spindle Cross Cooling Tower Fills/InfillHigh Quality Spindle Cross Cooling Tower Fills/Infill

High Quality Spindle Cross Cooling Tower Fills/Infill



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More