Introducing the EVL Cooling Tower Air Inlet Louver
The Newin EVL Series Air Inlet Louver is crafted from premium, high-strength PVC sheets. Skillfully bonded, it can be encased in a durable frame of either galvanized steel or stainless steel. This cutting-edge honeycomb inlet grille is engineered to optimize airflow into your cooling tower, efficiently filtering out impurities and preventing water splash. This innovative design minimizes risks of icing and proximate water damage, while significantly reducing unnecessary water loss.
Features
Features
- Enhance airflow efficiency and optimize cooling performance within the tower.
- Serve as a vigilant guard against debris intrusion, maintaining cleaner operations.
- Effectively prevent the splashing of water droplets, ensuring a safer environment.
- Significantly limit sunlight penetration to curb algae growth, promoting clearer water.
- Substantially reduce noise for a quieter operational experience.
- Engineered to achieve remarkably low pressure drop, enhancing system efficiency.
- Designed for straightforward installation and hassle-free cleaning and maintenance access.
- Versatile in application, ideal for both new installations and retrofits, covering air inlets
for package and field-erected counter flow, straight-sided cross flow towers, fresh air make-up systems, pollution control scrubbers, and VOC stripping operations.
Parameter
Properties
To ensure the perfect fit and function, we cater to a variety of specifications for the EVL air inlet louver, including options for length, width, materials, and thickness. Simply provide us with your detailed requirements, and we'll tailor a precise solution and offer that perfectly meets your needs. At Newin, we pride ourselves on our ability to accommodate every customer request. We also offer fill media that boasts flame retardant or antibacterial properties, available upon request, ensuring safety and hygiene.
Module Length (Max) |
mm |
2440 |
Module Width (Max) |
mm |
800 |
Module Thickness |
mm |
80 |
Flute Height |
mm |
25 |
Sheet Thickness - Before Forming |
mm |
0.5 |
Sheet Thickness - After Forming |
mm |
0.4 |
Max. application temp. (short time) - PVC |
°C |
60 |
Customized size and thickness available for special request. Contact Newin for details. |
Structure & Installation Drawing
For a seamless experience, Newin provides comprehensive support, including structural and installation drawing guidance, on-site storage advice, and a thorough quality control report delivered with your shipment. This ensures that our valued customers are well-prepared upon receiving the materials. Additionally, we offer OEM services and specialized mold design options to meet unique requirements upon request.

Application
Application & Usage
The state-of-the-art Newin EVL air inlet louver is meticulously engineered for use in counter flow cooling towers. Adhering to rigorous SGS testing and ASTM standards, this top-notch air inlet ensures exceptional quality and enhances the efficiency of your cooling tower to its peak. Simply provide us with your tower model or dimensions, and we will expertly assess and recommend the perfectly sized air inlet louver for seamless replacement.
Applicable Commercial Standards
The selection of sheet materials for our products is executed with precision, aligning strictly with SGS testing under ASTM standards. We offer comprehensive testing of each property or all properties based on your specific product requirements, ensuring a customized solution available at your request.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices
known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
Filed Data for Cross Flow Film Fill Replacement
For your maintenance or repair projects, trust Newin to deliver the data you need for assured quality and reliability. By filling in the measurement data below, you can rely on us for on-site visits or maintenance services. Our solutions are expertly engineered to seamlessly fit your cooling tower fills or components, ensuring lasting performance and satisfaction.

NEWIN Manufacturing Base

NEWIN FACTORY
Discover our state-of-the-art manufacturing base, strategically positioned in the dynamic and industrious heart of Huizhou, Guangdong. Spanning a remarkable 10,000 square meters, this expansive facility is the cornerstone of our innovative prowess, driving us towards unmatched excellence and breakthrough achievements in our field.
ISO CERTIFICATION
With a steadfast commitment to quality and environmental stewardship, our esteemed certifications include ISO9001:2015 for unparalleled Quality Management and ISO14001:2015, underscoring our dedication to exemplary Environmental Management practices.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Step into the future with our advanced Closed Type Cooling Tower Series, engineered with precision to deliver unmatched efficiency and superior performance for your needs.
·
NSH/ NST Introducing our expertly crafted Open Type Cooling Tower Series, designed to provide optimal performance with consistent reliability in every application.
·
NTG Explore our Industrial Type Cooling Tower Series, purposefully crafted to meet the stringent demands of industrial applications with unparalleled durability and efficiency.
·
NECN/NECH Our remarkable Evaporative Condenser sets new industry standards, delivering supreme cooling efficiency and outstanding performance.
·
NWFL Our Dry Air Cooler series exemplifies cutting-edge design and exceptional energy efficiency, redefining the benchmarks in cooling technology.
NEWIN is your reliable partner, providing an extensive array of cooling tower accessories. We manufacture and stock components to support maintenance and replacements across a wide range of sizes and types. Connect with us to customize the precise accessories that align perfectly with your distinct requirements.
CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (nozzles/ drift eliminator etc.)
· Heat exchange (PVC infills/ cooling coil etc.)
· Other accessories (air inlet louver/ valve etc.)
Packaging & Shipping
Open Type Cooling Towers Shipment: Dive into a realm of seamless delivery excellence with our open type cooling towers. These towers are meticulously crafted to embody the pinnacle of safety and reliability standards. Our proficient team masterfully orchestrates a flawless logistics experience, ensuring your order arrives promptly at your desired location, without a hitch! Trust us to deliver perfection that elevates the standards of excellence.
Closed Type Cooling Towers Shipment: Our closed type cooling towers are cradled with the utmost precision and care, ensuring they reach you in immaculate condition. We promise a secure and timely journey, preserving the unparalleled performance and integrity of our top-tier cooling systems from our factory floor to your doorstep. Rely on our seasoned expertise for a smooth, worry-free shipping experience, providing unwavering confidence at every stage of the process.
Technical Strength& Standards

Certifications