Effective Drift Eliminators for Open Air Contact Cooling Towers

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Effective Drift Eliminators for Open Air Contact Cooling Towers
  • Effective Drift Eliminators for Open Air Contact Cooling Towers
  • Effective Drift Eliminators for Open Air Contact Cooling Towers
  • Effective Drift Eliminators for Open Air Contact Cooling Towers
  • Effective Drift Eliminators for Open Air Contact Cooling Towers
  • Effective Drift Eliminators for Open Air Contact Cooling Towers
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
BAD
Condition
New
Ventilation Mode
Mechanical Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Noise Level
Low
After-Sales Service
One Year
Warranty
One Year
Material
PVC
Tower Shape
Blade or Cellular
Application Fields
Cooling Tower
Transport Package
20/40/40hq Container with Loose Packing
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000

Product Description

Introducing the exceptional Newin Cellular Type Drift Eliminator, also known as the PVC Drift Eliminator, meticulously engineered for peak performance in cooling towers. Designed to significantly reduce drift loss, this advanced solution ensures optimal cooling efficiency and sustainability in open-air contact cooling tower operations.
Effective Drift Eliminators for Open Air Contact Cooling Towers
Product Description

BAD Series – Drift Eliminators Newin BAOur D cellular drift eliminator stands as a guardian of efficiency, expertly removing even the tiniest water droplets entrained in the exhaust air. By doing so, it significantly reduces potential nuisances and health issues that arise if these droplets escape along with the heated air at the top of the tower. The BAD series drift eliminators are ingeniously engineered to craft a complex, tortuous path for the air stream. As water droplets traverse this path, they are compelled to shift direction, impacting the side walls of the drift eliminator, which leads to their coalescence and subsequent drainage back into the cooling tower's wet section. This process ensures an effective reduction in drift loss, enhancing the overall performance of your cooling tower.

FEATURES

- Boasting anti-aging properties and superior water absorption, our drift eliminators offer unparalleled longevity and efficacy.
- With low airflow resistance combined with high structural strength, they ensure optimal performance without compromising durability.
- Designed for easy installation and extended service life, these drift eliminators are the perfect choice for long-term efficiency.
- They can also serve as a replacement option for air inlet louvers, offering versatile utility.
Parameter

PROPERTIES

Our Effective Drift Eliminators for Open Air Contact Cooling Towers are tailored to meet an array of specific requirements, whether it be varying lengths, widths, materials, or thicknesses. At Newin (Guangdong) Machinery Co., Ltd., we invite you to share your precise needs with us to ensure an accurate solution and competitive offer. We excel at accommodating every customer demand, providing fill media options in both flame retardant and anti-bacterial executions upon request.
Module Length (Max)  mm 2440
Module Width  (Max)  mm 500
Module Height  mm 140
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.38
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


STRUCTURE & INSTALLATION DRAWING

Newin is committed to enhancing your experience with comprehensive structure and installation drawing guidance, coupled with meticulous job site storage advice and a thorough quality control report accompanying each shipment. This ensures you have all the essential information at your fingertips when receiving your materials. We also offer OEM or bespoke mold design services to cater to unique project needs, available upon request.

Effective Drift Eliminators for Open Air Contact Cooling Towers

Application

APPLICATION & USAGE

The innovative Newin BAD cellular drift eliminator is designed for optimal replacement of BAC components. Our drift eliminators are perfect for cooling towers, ensuring top-notch performance with SGS-certified testing under ASTM Standards. This rigorous quality control guarantees maximum efficiency for your cooling towers. Simply provide us with your tower model or specifications, and we will accurately calculate the required number of sheets for replacement.

Effective Drift Eliminators for Open Air Contact Cooling Towers

APPLICABLE COMMERCIAL STANDARDS

The sheet materials are meticulously tested to meet the highest SGS standards in accordance with ASTM protocols. All the essential properties, or any specific attributes you require, are available for testing upon request.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.


FIELD DATA FOR CELLULAR DRIFT ELIMINATOR REPLACEMENT

For your maintenance cooling tower or repair projects that demand unparalleled quality and reliability, trust Newin. We offer site visits or maintenance services that are precisely engineered to integrate seamlessly with your cooling tower fills or components.
Effective Drift Eliminators for Open Air Contact Cooling Towers

NEWIN Manufacturing Base

Effective Drift Eliminators for Open Air Contact Cooling Towers
NEWIN FACTORY
Embark on an inspiring journey through our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Spanning an expansive 10,000 square meters, this facility is a beacon of innovation and technological advancement. Immerse yourself in an environment where pioneering breakthroughs and excellence converge, setting new standards in manufacturing.

ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: ISO9001:2015 Quality Management and ISO14001:2015 Environmental Management. These certifications exemplify our dedication to setting industry benchmarks for excellence and responsible practices.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Effective Drift Eliminators for Open Air Contact Cooling Towers
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Immerse yourself in unrivaled efficiency and groundbreaking innovation with our Closed Type Cooling Tower Series. Each model is meticulously designed to deliver superior performance and unmatched reliability, embodying the pinnacle of cooling tower technology.
· NSH/ NST Discover the unwavering reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance. These towers set industry standards and consistently exceed expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty applications. These towers ensure resilience and power at every turn, meeting the demands of the most challenging environments.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models. These models set new standards in performance and operational excellence, revolutionizing the cooling industry with unparalleled innovation.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler. Expertly designed for superior airflow and maximum efficiency, this cooler optimizes every facet of cooling, delivering unmatched results.

Effective Drift Eliminators for Open Air Contact Cooling Towers
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit a variety of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories for optimal cooling tower performance.

CONTAIN:
· A robust Fan drive system, featuring a fan, fan stack, reducer, motor, and shaft. Engineered for durability and precision, this system ensures seamless operation.
· Highly efficient Water distribution components, with precision-engineered nozzles and advanced drift eliminators. These components optimize water management for superior performance.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils. Crafted for optimal performance and energy efficiency, these options enhance thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system. These accessories enhance overall functionality and efficiency, elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Our meticulously engineered open-type cooling towers are expertly packaged, ensuring they reach you in immaculate condition. We prioritize the utmost safety and security, employing premium materials and strategic packing techniques to provide an impregnable shield against any potential transit damages. Revel in seamless logistics and prompt delivery, ensuring that your cooling solutions become operational without delay for maximum efficiency and performance.

Effective Drift Eliminators for Open Air Contact Cooling Towers
Closed type cooling towers shipment: Experience peace of mind with our robust packaging solutions for closed-type cooling towers. Each unit is meticulously encased to endure the rigors of transport, ensuring arrival at your site in pristine condition and ready to deliver top-tier performance. Our steadfast dedication to quality control and punctual shipping empowers you to concentrate on what truly matters - harnessing our cutting-edge cooling technology to enhance your applications and achieve unparalleled outcomes.
Effective Drift Eliminators for Open Air Contact Cooling Towers
Effective Drift Eliminators for Open Air Contact Cooling Towers
Technical Strength& Standards

Effective Drift Eliminators for Open Air Contact Cooling Towers
Effective Drift Eliminators for Open Air Contact Cooling Towers

Certifications

Effective Drift Eliminators for Open Air Contact Cooling TowersEffective Drift Eliminators for Open Air Contact Cooling TowersEffective Drift Eliminators for Open Air Contact Cooling TowersEffective Drift Eliminators for Open Air Contact Cooling Towers

Effective Drift Eliminators for Open Air Contact Cooling Towers


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier