PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
  • PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
  • PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
  • PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
  • PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
  • PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
SHH
Condition
Cooling Tower
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Material
PVC, PP
Transport Package
Woodencase 20gp/40gp Container
Specification
950 x 950 mm, 950 x 1270 mm
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
500000/Year

Product Description

Introducing our exceptional Cooling Tower Cross Flow Fill, crafted meticulously from premium PVC materials, available in versatile widths of 950mm and 1270mm. This innovative fill is designed to optimize airflow and cooling efficiency, ensuring your cooling tower operates at peak performance with reduced energy consumption.

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
Product Description

SHH Discover the Newin SHH series cross flow film fill, expertly designed for square cooling towers. This cutting-edge product boasts advanced technology with a remarkable lifespan, low resistance, and lightweight construction. Its surface is impeccably smooth and radiant, with robust pressure strength to prevent breakage upon contact. Non-toxic and non-irritating, it assures superior safety. Crafted from high-quality new PVC raw materials, it guarantees exceptional quality and durability. Rigorous testing and production operations confirm its outstanding cooling performance.


FEATURES

- Crafted with modified PVC sheets, the unique formula delivers unmatched strength and exceptional durability, ensuring long-lasting performance.

- Utilizing advanced Vac form special processing, featuring an integrated liquid baffle plate on the fan side edge, it minimizes water drift loss while maximizing the heat exchange efficiency between water and air.

- Standard heat resistance accommodates temperatures up to 50°C, with an optional heatproof specification available to handle temperatures reaching 80°C.


PICTURE IN DETAIL

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology

Parameter

PROPERTIES

We understand the diverse needs of our clients when it comes to SHH film fill's dimensions, materials, and thickness. At Newin, we are committed to tailoring our solutions to meet your specific requirements accurately. Our PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology can be customized to your desired length, width, material, or thickness specifications. Do inform us of your precise needs to ensure you receive the perfect solution. Additionally, we offer fill media in both flame-retardant and anti-bacterial variants, available upon request.
Module Length (Max)  mm 950
Module Width   mm 950/1270
Module Depth   mm -
Flute Height  mm 20
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 147
Sheet Thickness - Before Forming  mm 0.32
Sheet Thickness - After  Forming  mm 0.28
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.

STRUCTURE & INSTALLATION DRAWING

Newin is dedicated to ensuring seamless integration of our products. We provide comprehensive structure and installation guidance, along with job site storage recommendations and a quality control report, accompanying your shipment. This way, we ensure that our customers have all the information they need upon receiving the materials. For those requiring unique specifications, we also offer OEM services or special mold designs tailored to your specific needs, available upon request.
PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
Application

APPLICATION & USAGE

The Newin SHH Film Fill is expertly designed for the Shinwa cooling tower series, showcasing unparalleled versatility and performance. SNC-U, SDC-U Field Erected, rigorously tested with SGS under ASTM Standards to assure superior quality infill, guaranteeing maximum efficiency of your cooling tower. Share with us your tower model or dimensions, and we'll precisely calculate the number of sheets required for seamless replacement in your cooling tower.
PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology

FILED DATA FOR CROSS FLOW FILM FILL REPLACEMENT

Provide the measurements below for your maintenance cooling tower or repair projects. Trust in Newin for quality and reliability; our experts are available for site visits or maintenance services, ensuring our engineered solutions perfectly fit your cooling tower fills or components.
PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
Options

Discover Other Exciting Opportunities:

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
NEWIN Manufacturing Base

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
NEWIN FACTORY
Embark on an awe-inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the dynamic industrial hub of Huizhou, Guangdong. Stretching over an expansive 10,000 square meters, this facility stands tall as a beacon of innovation, excellence, and cutting-edge technological advancements.

ISO CERTIFICATION
We proudly emphasize our unwavering commitment to unrivaled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for unmatched excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unparalleled efficiency and groundbreaking innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model showcases the pinnacle of cooling tower technology.
· NSH/ NST Discover the unwavering reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry benchmarks and consistently exceeding expectations for enduring excellence.
· NTG Explore the extraordinary capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unparalleled results.

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit a wide variety of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories designed for your cooling tower to achieve optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Discover unparalleled security and precision through our masterfully orchestrated transportation services specifically for open-type cooling towers. Each tower is meticulously wrapped in top-tier materials and employs state-of-the-art packing methodologies, ensuring they reach your facility in impeccable form. We take pride in our unyielding dedication to safeguarding your investment, providing full coverage against any potential transit hazards. Embrace the ease of our flawless logistics and timely delivery, meticulously orchestrated to activate your cooling solutions without any delay, thus ensuring operational continuity.

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
Closed type cooling towers shipment: Revel in the confidence that comes with our exceptionally crafted packaging solutions, meticulously tailored for closed-type cooling towers. Each unit is carefully encased with unparalleled attention to detail and robustness to withstand even the harshest transit scenarios, guaranteeing they arrive in immaculate condition, primed for immediate deployment. Our unwavering commitment to excellence and expeditious delivery empowers you to seamlessly integrate our state-of-the-art cooling innovations into your operations, free from any logistical inconveniences, thus streamlining your implementation process.
PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
Technical Strength& Standards

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology

Certifications

PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology
PVC Cooling Tower Fill with Enhanced Offset Fluted Airflow Technology

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More