Introducing the High-Performance Newin Adiabatic Cooler: Your Ultimate Choice for Optimal Refrigeration Solutions.
NWFL-VA Experience the future of cooling with the NWFL-VA series - a trailblazing V-type dry air cooler, expertly designed with a state-of-the-art Adiabatic Cooling System. Designed to deliver exceptional cooling efficiency all year round, this system is the perfect fit for data centers and a broad spectrum of other essential facilities. This groundbreaking solution ensures an exemplary free cooling experience, significantly curtailing water usage in comparison to conventional evaporative cooling technologies. This makes it the ideal sustainable and economical solution for the needs of contemporary businesses.
Features
· Experience the ingenious V-type configuration, harmoniously paired with a superior adiabatic cooling system designed to impress.
This system delivers exceptional cooling efficiency, all while maintaining remarkably low water consumption, setting a new standard in refrigeration.
· Featuring optimally efficient components like the groundbreaking advanced EC motor,
it ensures maximum system efficiency and presents significant energy savings, making it a sustainable choice.
· Thoughtfully designed with substantial redundancy,
it guarantees the complete elimination of any potential thermal performance loss, offering peace of mind.
· With high reliability at its core, it also offers unmatched ease of maintenance, ensuring a seamless user experience.
Working Principle

When the NWFL-VA adiabatic cooler springs into action:
Experience a refreshing revolution in cooling with the NWFL-VA adiabatic cooler. As revitalizing cold water cascades gracefully from the cooler's apex, it seamlessly infuses the high-efficiency evaporative cooling pads. Simultaneously, the advanced EC axial fan ingeniously draws in cool, dry air, guiding it skillfully over the pads for expert precooling. This cutting-edge adiabatic air precooling significantly elevates cooling capacity, ensuring superior refrigeration that efficiently chills the warm process fluid with unparalleled precision.
Series |
Type |
Capacity |
1. Fan Drive System |
2. Heat Exchange System |
3. Adiabatic Pre-cooler |
NWFL-VA |
V |
Range |
EC axial fans |
Finned coil |
Evaporative cooling pads |
Maximum thermal performance |
300~1680kw |
Intelligent frequency conversion,
more energy saving |
Maximum heat transfer surface |
Precooling the ambient air temperature,
improving higer cooling efficency |
*4.The wake up is on the top of the pads can ensure the cool dry air in adiabatic precooling process when the pump is not running. |
*5. Recirculation system is designed for further reduce the total water consumption. |
Adiabatic cooling
system |
Exceeding 90% annual water saving compared to normal cooling tower |
Application |
Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc. |
Parameter
Model |
Configuration Mode |
Flow |
Cooling Capacity |
Dimension (mm) |
Nos of Fins |
Fan Diameter |
Power |
F/V |
m3/h |
kw |
L |
W |
T |
nos |
mm |
kw |
NWFL-300VA |
V |
52 |
300 |
4000 |
1290 |
198 |
2 |
EC900 |
7.6 |
NWFL-600VA |
V |
104 |
600 |
4000 |
1290 |
198 |
4 |
EC900 |
15.3 |
NWFL-520VA |
V |
90 |
520 |
4500 |
1786 |
198 |
2 |
EC800 |
12.6 |
NWFL-1040VA |
V |
180 |
1040 |
4500 |
1786 |
198 |
4 |
EC800 |
25.3 |
NWFL-600VA |
V |
105 |
600 |
4000 |
2280 |
198 |
2 |
EC900 |
15.3 |
NWFL-1200VA |
V |
210 |
1200 |
4000 |
2280 |
198 |
4 |
EC900 |
30.6 |
NWFL-840VA |
V |
144 |
840 |
5500 |
2777 |
198 |
2 |
EC900 |
19.1 |
NWFL-1680VA |
V |
288 |
1680 |
5500 |
2777 |
198 |
4 |
EC900 |
38.2 |
* Important Notice: The data presented in this table provides a snapshot at the time of its release. For precise engineering and construction projects, it is crucial to avoid relying solely on this information. We warmly invite you to engage with our expert sales team and engineers, who will be delighted to provide you with comprehensive and precise details, ensuring an informed and confident purchase decision.
* Customization Alert: For projects requiring multiple cells, we highly recommend consulting directly with the manufacturer to receive bespoke solutions tailored to your unique requirements. Please be advised that NEWIN reserves the exclusive right to alter any parameters or dimensions within this table without prior notification, ensuring our products remain at the cutting-edge of innovation.
Components& Options
· Heavy-duty Construction
Crafted with meticulous precision, our galvanized steel panel is fortified with the groundbreaking NWN-Armour anti-corrosion coating. This robust barrier offers a stainless-steel level of resistance, empowering the system to function seamlessly with higher concentration cycles, thereby curbing water usage significantly. What's more, should any damage occur, it can be effortlessly mended, ensuring the system's durability and peak efficiency are maintained over time.
· V Type Finned Coil Heat Exchanger
This cutting-edge finned coil heat exchanger is engineered with precision, featuring copper tubes and aluminum fins uniquely spaced to maximize heat transfer. The structured design ensures each copper tube is meticulously brazed to coil headers and flared to finned coils, guaranteeing exceptional thermal conduction and stellar performance.
· EC Axial Fan
- With its sophisticated EC motor, this fan is equipped with a straight-shaft drive, boasting an IP55 protection grade and F insulation. Specifically designed for high-heat and humidity operations, it promises smooth, dependable functionality. Its energy efficiency exceeds IE4 standards, positioning it as an eco-conscious choice.
- The fan is designed with high-capacity tapered roller bearings, ensuring impressive load-bearing capabilities and a remarkable lifespan, extending beyond 20,000 hours of service.
- Through expert static and dynamic testing, noise is expertly minimized, maintaining exceptional heat exchange efficiency. The EC fan system employs PFC technology to keep harmonics below 35%, ensuring remarkable static efficiency, even at lower speeds.
· Adiabatic Pre-cooler
- The cooling pads, constructed from advanced impregnated cellulose, rest on a sturdy stainless steel framework, ensuring thorough water distribution from the top down. This ensures complete saturation, delivering superior evaporative cooling.
- Treated with anti-UV on the external surface, these cooling pads boast enhanced durability and can be effortlessly pressure-cleaned, extending their service life significantly.
- Equipped with a water circulation pump, these pads enhance cooling even during the height of summer, achieving optimal conditions effortlessly.
· Adiabatic Intelligent Controls
- Our intelligent frequency conversion in EC fans dynamically adjusts to the site's conditions, maximizing energy savings and operational efficiency.
- Engineered to perform efficiently even in dry environments where water use is limited, ensuring continuous, reliable operation.
· Options
- Enhance coil resistance for increased durability.
- Include safeguards to prevent coil freeze-up.
- Choose a low noise upgrade for a quieter operational experience.
- Increase redundancy measures to ensure unwavering reliability. For any bespoke requests, please contact a NEWIN sales representative to achieve your customized solution.
NEWIN Manufacturing Base

NEWIN FACTORY: A powerhouse of precision and efficiency, delivering top-tier machinery solutions.
Our expansive manufacturing base is strategically located in Huizhou, Guangdong, spanning an impressive 10,000 square meters, fully equipped for world-class production.
ISO CERTIFICATION: A testament to our unwavering commitment to excellence and sustainable practices.
ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification boast our adherence to rigorous international standards.
WORKSHOPS: Each dedicated to crafting perfection with advanced technology and skilled expertise.
Welding Workshop: Where precision meets durability, ensuring the integrity of every joint and structure.
Filler Thermoforming Workshop: Mastering the art of thermoforming to create essential components with precision.
Sheet Metal Processing Workshop: Crafting robust and refined metal parts with cutting-edge techniques.
Cooling Tower Assembly Workshop: Assembling innovation and efficiency in every cooling tower built.
TESTING: Rigorous and comprehensive, ensuring every product meets the highest standards of performance.
Independent Testing LAB: A hub of quality assurance, where every product is meticulously tested for excellence.
NEWIN COOLING TOWERS: Embodying innovation and efficiency, our wide range of towers caters to diverse industrial needs.
·
NWN/ NWF/ NCFN: Engineered for optimal performance, these closed type cooling towers are at the forefront of modern technology. Closed Type Cooling Tower Series: Designed for superior energy efficiency and reliability, even in demanding environments.
·
NSH/ NST: Open Type Cooling Towers that provide flexibility and high performance for a variety of applications. Open Type Cooling Tower Series: Versatile and robust, perfect for both standard and unique cooling requirements.
·
NTG: Industrial Type Cooling Tower Series, delivering powerful cooling solutions for heavy-duty applications. Industrial Type Cooling Tower Series: Engineered for maximum durability and efficiency in industrial settings.
·
NECN/NECH: Evaporative condenser offerings that combine high performance with energy-saving features. Evaporative Condenser: A cutting-edge solution for efficient heat rejection, ensuring high thermal performance.
·
NWFL: Dry Air Cooler for high-efficiency cooling with reduced water usage, ideal for eco-conscious operations. Dry Air Cooler: An environmentally-friendly choice that excels in reducing operational costs while providing excellent cooling.
NEWIN stocks a comprehensive array of cooling tower accessories designed to accommodate maintenance and replacement needs across a spectrum of tower sizes and models. Reach out to us for custom accessory solutions tailored to your specific requirements.
CONTAIN: A complete suite of essential components engineered for superior functionality and easy integration.
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.): Precision components ensuring dependable and efficient air circulation.
· Water distribution (nozzles/ drift eliminator etc.): Engineered for optimal flow and distribution, minimizing water loss.
· Heat exchange (PVC infills/ cooling coil etc.): Designed for effective heat transfer, enhancing overall system efficiency.
· Other accessories (air inlet louver/ valve etc.): Comprehensive solutions for seamless operation and maintenance.
Packaging & Shipping
Open type cooling towers shipment: Discover the art of perfect logistics with our open-type cooling towers. At Newin (Guangdong) Machinery Co., Ltd., we expertly manage every step of the process, ensuring each unit is packed with precision and care. This meticulous attention guarantees that your cooling towers arrive at their destination in immaculate condition, where and when you need them most.
Closed type cooling towers shipment: Our closed-type cooling towers shipment process is an embodiment of excellence, characterized by painstaking attention to detail. Every unit is handled with utmost care to ensure that it arrives at your location in flawless condition. Our shipping process at Newin (Guangdong) Machinery Co., Ltd. is crafted to cater to your specific requirements, promising a timely and secure delivery experience that exceeds expectations.
Technical Strength& Standards


Certifications