MVS Series Mechanical Vibration Switch: Unveiling the pinnacle of precision, the MVS Series Mechanical Vibration Switch stands as a testament to innovation and reliability in equipment monitoring. Designed with cutting-edge technology and engineering excellence, this switch ensures unmatched efficiency and accuracy in detecting vibrations, safeguarding your machinery with unprecedented ease. Experience the future of equipment monitoring with the MVS Series, where performance meets dependability.
Product Description
MVSMeet the MVS1110, a pinnacle of pure mechanical engineering in vibration monitoring solutions. This cutting-edge mechanical vibration switch is a sophisticated device comprised of intricately designed components such as springs, induction mechanisms, adjustment rods, reset buttons, micro switches, and more. Its core component, the sensing mechanism, operates in two distinct states: non-triggered and triggered. During standard operations, the mechanism rests in a non-triggered state. Once the machinery's vibration level escalates to or surpasses a predetermined threshold, the mechanism gracefully transitions to a triggered state, thereby shifting the micro switch contact state. The COM and NC contacts pivot from a normally closed to an open state, while the COM and NO contacts transition from a normally open to a closed state, thereby effortlessly enabling an alarm function or seamlessly shutting down equipment power.

Delve into the workings of this remarkable mechanical vibration switch, where the sensing mechanism, tensioned by a support rod and spring, pivots with finesse around its axis. This movement is sensitive to the magnitude of vibration acceleration. Adjusting the rod vertically alters the pre-stress on the induction mechanism, which sets the switch's activation point. Installed vertically, the design even accounts for gravity's influence. Illustrated in Figure 1, when vibrations remain below the pre-stress level, the switch rests in a non-triggered state. However, as shown in Figure 2, surpassing this threshold triggers the switch. The MVS1110's set point adjustment is ingeniously achieved by altering the spring angle with an adjustment lever, offering precision and adaptability in monitoring.
Upon reaching the trigger state, the sensing mechanism activates a chain reaction that pushes the micro switch's rocker arm upwards. This decisive motion alters the micro switch's contact configuration, outputting a precise contact signal. This capability ensures total control over the accompanying control loop, offering unmatched protection and alert functionality for rotational equipment. Through this elegant transition, the MVS1110 not only fortifies safety but also optimizes operational efficiency.
Application

NEWIN Manufacturing Base

NEWIN FACTORY: The Epitome of Precision and Superior Quality
Nestled in the dynamic hub of Huizhou, Guangdong, the NEWIN Manufacturing Base stands as a monumental beacon of technological prowess and innovation. Spanning a remarkable 10,000 square meters, this cutting-edge facility epitomizes our unwavering commitment to machinery excellence and unparalleled craftsmanship.
ISO CERTIFICATION: The Benchmark of Rigorous Standards and Quality Assurance
NEWIN boasts ISO9001:2015 accreditation for our exemplary Quality Management Systems and ISO14001:2015 for our visionary Environmental Management Systems. These prestigious certifications reflect our relentless pursuit of extraordinary quality while advocating for sustainable and eco-conscious practices.
WORKSHOPS: Where Mastery Meets Pioneering Innovation
Welding Workshop: Precision in every weld and mastery in every joint, reflecting a revolution in industry quality standards and craftsmanship.
Filler Thermoforming Workshop: Leading excellence and forging the future of thermoforming with groundbreaking innovation.
Sheet Metal Processing Workshop: Crafting durability and ensuring reliability through advanced metalworking techniques.
Cooling Tower Assembly Workshop: Assembling with precision, delivering performance that consistently surpasses expectations.
TESTING: Guaranteeing Unmatched Quality and Peak Performance
Independent Testing LAB: Conducting exhaustive evaluations to ensure our products consistently achieve superior quality outcomes.
NEWIN COOLING TOWERS: Crafted with Excellence in Mind
·
NWN/ NWF/ NCFN: Our ingeniously engineered closed type cooling tower series, designed to deliver unrivaled performance. Closed Type Cooling Tower Series: Engineered for superior thermal efficiency and steadfast dependability.
·
NSH/ NST: Aligning cutting-edge technology with our open type cooling tower series, setting new industry standards. Open Type Cooling Tower Series: Delivers unbeatable performance and reliability across diverse cooling applications.
·
NTG: Industrial Type Cooling Towers engineered to withstand intense industrial demands with robust solutions. Industrial Type Cooling Tower Series: Specifically designed to meet the demanding challenges of industrial environments.
·
NECN/NECH: Leading the frontier with evaporative condensers tailored for contemporary applications, ensuring maximum efficiency. Evaporative Condenser: Delivers peak efficiency without compromise, setting new industry benchmarks.
·
NWFL: Introducing a state-of-the-art dry air cooler engineered for exceptional performance in any weather condition. Dry Air Cooler: Employing advanced technology to deliver reliable and effective cooling solutions.
NEWIN provides a wide and comprehensive range of meticulously crafted cooling tower accessories. These components cater to the maintenance and replacement needs of virtually any cooling tower size or type. Get in touch with us to customize accessories precisely tailored to your exact specifications.
CONTAIN: Comprehensive Spectrum of Essential Components
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.): Engineered with precision for optimal performance excellence.
· Water distribution (nozzles/ drift eliminator etc.): Engineered to ensure uniform flow and highly efficient distribution.
· Heat exchange (PVC infills/ cooling coil etc.): Crafted with superior materials to boost heat transfer efficiency.
· Other accessories (air inlet louver/ valve etc.): Quality components ensuring seamless and efficient operation.
Packaging & Shipping
Open Type Cooling Towers Shipment: Experience a seamless and flawless transition with our Open Type Cooling Towers, meticulously engineered to deliver unparalleled air conditioning efficiency. Each unit, crafted with precision and care, is delivered to your doorstep, showcasing the pinnacle of quality and innovation. Designed to amplify your cooling capacities to unprecedented levels, these towers epitomize performance excellence and reliability.
Closed Type Cooling Towers Shipment: Our Closed Type Cooling Towers are dispatched adhering to rigorous safety and reliability standards. From our cutting-edge facilities, these durable and high-efficiency cooling systems are transported directly to your site, fully equipped to provide outstanding performance and effortlessly meet all your cooling requirements with superior ease.
Technical Strength& Standards

Certifications