Introducing the Newin Cellular Type Drift Eliminator, a pioneering solution in enhancing the efficiency of your cooling towers. This exceptional PVC Drift Eliminator is expertly crafted to provide superior performance and longevity. Experience the ultimate in drift elimination technology with Newin's state-of-the-art design, ensuring optimal operations for your cooling towers.
Product Description
BAD Newin BAIntroducing the Newin Cellular Type Drift Eliminator, an innovative solution designed specifically for efficient cooling tower applications. This remarkable product ensures the removal of minuscule droplets of water that are carried by the exhaust air, thereby significantly reducing any potential nuisance and health concerns that such droplets may cause if they escape through the tower along with the heated air. The BAD series drift eliminators from Newin have been meticulously engineered to create an intricate pathway for the air stream. As the water droplets navigate through this maze, they are compelled to change direction, causing them to collide with the side walls of the drift eliminator. This effectively leads to the coalescence of the droplets, allowing them to drain seamlessly back into the wet section of the cooling tower, ensuring maximum efficiency and performance.
FEATURES
- Exceptional anti-aging properties paired with high water absorption capabilities.
- Engineered for low airflow resistance while offering substantial structural strength.
- Designed for effortless installation and boasts an impressively long service life.
- Versatile design that can also be utilized as a replacement for air inlet louvers.
Parameter
PROPERTIES
When considering the various demands for BAD drift eliminators, such as specific length, width, materials, or thickness, we invite you to provide us with your comprehensive requirements. This enables us to deliver the most precise solution and quotation tailored to your needs. At Newin, we pride ourselves on meeting a diverse array of customer specifications. Furthermore, our fill media can be customized with flame retardant or anti-bacterial properties, available upon request, ensuring safety and efficiency for your cooling towers.
Module Length (Max) |
mm |
2440 |
Module Width (Max) |
mm |
500 |
Module Height |
mm |
140 |
Flute Height |
mm |
25 |
Sheet Thickness - Before Forming |
mm |
0.45 |
Sheet Thickness - After Forming |
mm |
0.38 |
Max. application temp. (short time) - PVC |
°C |
60 |
Customized size and thickness available for special request. Contact Newin for details. |
STRUCTURE & INSTALLATION DRAWING
Newin ensures a seamless experience by supplying detailed structure and installation drawing advice, complemented with jobsite storage guidance and a quality control report included with every shipment. This attention to detail guarantees that our customers are well-prepared upon receipt of materials. Additionally, we offer OEM services or bespoke mold designs to cater to specific requests, reinforcing our commitment to exceptional customization.

Application
APPLICATION & USAGE
The Newin BAD Cellular Drift Eliminator is expertly designed for replacing BAC systems. Tailored for cooling towers, and rigorously tested with SGS protocols under ASTM Standards to ensure top-tier quality infill. This guarantees the utmost efficiency for your cooling tower experience. Simply provide us with your tower model or its dimensions, and we will accurately determine the number of sheets required for its replacement.

APPLICABLE COMMERCIAL STANDARDS
Our sheets material adheres strictly to SGS testing in accordance with ASTM standards. Whether it's individual properties or a comprehensive suite of features, our products can be tested per your request.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake
sufficient tests to determine the suitability for any intended use of the material. |
FILED DATA FOR CELLUAR DRIFT ELIMINATOR REPLACEMENT
Please complete the measurements below for your cooling tower maintenance or repair projects. When quality and dependability are key, trust Newin for site visits or maintenance services. Our solutions are meticulously engineered to seamlessly integrate with your cooling tower fills or components.
NEWIN Manufacturing Base

NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements, showcasing our commitment to quality and innovation in every facet.
ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification. These certifications set the benchmark for excellence, reflecting our dedication to maintaining the highest standards.
WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop
TESTING
Dedicated Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series. Meticulously designed to deliver superior performance and unmatched reliability, each model embodies the cutting-edge of cooling tower technology, setting new standards in the industry.
·
NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance. Setting industry standards, these towers exceed expectations for enduring excellence and innovative design.
·
NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications. These towers ensure resilience and power at every turn, making them ideal for the most challenging environments.
·
NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models. These models set new standards in performance and operational excellence, revolutionizing the cooling industry with their advanced technology.
·
NWFL Harness the transformative power of advanced technology with our Dry Air Cooler. Expertly designed for superior airflow and maximum efficiency, it optimizes every facet of cooling for unmatched results, ensuring top-tier performance.
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.
CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision. This ensures seamless operation and long-lasting performance.
· Highly efficient water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance. These components optimize water management, enhancing overall efficiency.
· Premium heat exchange options, complete with top-quality PVC infills and cooling coils. Crafted for optimal performance and energy efficiency, they enhance thermal regulation and reduce energy consumption.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system. These enhance overall functionality and efficiency, elevating performance to new heights.
Packaging & Shipping
Open type cooling towers shipment: Experience unparalleled assurance with our meticulously engineered open-type cooling towers. Each unit is expertly packaged, ensuring they reach you in pristine condition. We prioritize supreme safety and security by employing only premium materials and strategic packing techniques, forming an impregnable shield against any potential transit damages. Enjoy seamless logistics and rapid delivery, ensuring that your cooling solutions become operational without delay, maximizing efficiency and performance.
Closed type cooling towers shipment: Discover peace of mind with our robust packaging solutions for closed-type cooling towers. Each unit is meticulously encased to withstand the rigors of transport, guaranteeing arrival at your site in pristine condition, ready to deliver top-tier performance. Our steadfast dedication to quality control and punctual shipping empowers you to focus on what truly matters - leveraging our state-of-the-art cooling technology to elevate your applications and achieve extraordinary results.
Technical Strength& Standards


Certifications