Industrial Usage Cooling Tower Chemical Ferilizer Industry Sugar Processing Industry
Model Description
Features
♦ Space saving, light-duty structures
♦ Energy saving, low noise
♦ Perfect corrosion resistance
♦ Convenient combination and easy maintenance
Components Instruction
STRUCTURE
NTG Series cooling tower shall be proposed in compliance with the specification of cooling tower for this job, All framework and structural members shall be constructed of Reinforced Concrete (supplied by customer) / of Hot-dip Galvanized Steel (supplied by vender) , to provide maximum strength and durability.
FAN STACK
The FRP velocity recovery fan stack is used in the proposed cooling tower. This profile of fan stack is designed on basis of the theory of air channel uniformity. It will guide the air flow exit vertically which will reduce the effect of re-circulation and also reduce the noise level.
DISTRIBUTION SYSTEM
Using the unique overflow device to realize smooth and even water distribution under different sustem load, the device completely eliminates the drift loss of coolig tower. Hot water basin cover avoids water pollution by foreign objects falling into hot basin. Meantime, it avoids direct sunlight and inhabit growth of algae.
FILL PACKING
Used high quality & improved performance PVC with good material, it is high cooling efficiency and anti-corrosive & UL V-0. Brand new PVC materials, integrated eliminators and louvers. The infills are hanging type, environmental friendly and big coefficient of heat transfer, good hydrophilicity. Small wind resistance, high ventilation performance. Special material for option if high entering water temperature.
FRAME STRUCTURE AND FASTENERS
Leading structure design and high-quality materials to make frame structure and fasteners, the standard configuration of structure and fasteners is superior hot-dip galvanized steel, good anti-corrosion, design lifespan is more than 15 years. Stainless steel or F.R.P frame structure available for poor water soltion, and SUS304 or SUS316L for fasteners.
Optional Accessories
♦ Noise reduction upgrade ♦ Anti-Freeze heater
♦ Vibration isolator & rubber mat ♦ Stainless steel framework / bolts and nuts (304 / 316)
♦ High-temperature upgrade ♦ Dual-speed Motor & VFD motorAnti-Freeze heater
Technical data
Item |
Water Flow
(m3/h) |
Cooling Capacity
Kcal/h |
Dimention
(mm) |
Fan |
Water
Pressure
(x104Kpa) |
Weight (kg) |
Model |
Length |
Width |
Height |
Diameter
(mm) |
Power
(Kw) |
Dry |
Wet |
NTG-800 |
800 |
8.0x106 |
7400 |
7400 |
7800 |
4700 |
30 |
8 |
11.63 |
18.45 |
NTG-1000 |
1000 |
1.0x107 |
9000 |
9000 |
8700 |
5460 |
45 |
8.8 |
19.68 |
31.23 |
NTG-1500 |
1500 |
1.5x107 |
10500 |
10500 |
9500 |
6000 |
55 |
10 |
29.34 |
46.75 |
NTG-2000 |
2000 |
2.0x107 |
12000 |
12000 |
10200 |
7700 |
90 |
11 |
45.03 |
68.69 |
NTG-2500 |
2500 |
2.5x107 |
13500 |
13500 |
10700 |
8000 |
132 |
11.5 |
46.2 |
75.3 |
NTG-3000 |
3000 |
3.0x107 |
15000 |
15000 |
11400 |
8530 |
160 |
12 |
65 |
99.2 |
NTG-3500 |
3500 |
3.5x107 |
16000 |
16000 |
12100 |
9140 |
160 |
13.3 |
76.05 |
104.8 |
NTG-4000 |
4000 |
4.0x107 |
17400 |
17400 |
12400 |
9140 |
200 |
13.5 |
78.5 |
132 |
Casing |
Fiberglass Reinforced Polyester |
Frame |
Galvanized steel / Concrete |
Infill |
PVC |
Drift eliminator |
PVC |
Distribution system |
Galvanized steel & P.V.C |
Ice-melting pipe |
Galvanized steel |
Clapboard |
Fiberglass Reinforced Polyester |
Pool |
Concrete |
NEWIN Industry cooling tower project cases
Factory
Cooling Tower Shipment
NEWIN COOLING TOWER