Overview
Our Industrial Geareducers are expertly crafted and meticulously engineered to cater specifically to the cooling towers within expansive industrial and power plant settings. With an innovative design that transcends conventional standards, these geareducers are crafted to ensure optimal air circulation through the tower while significantly reducing maintenance demands.
Gearbox Reducer
Our second gear transmission reducers combine the power of spiral bevel and helical gear systems to deliver a robust performance. Featuring a compact design, they offer significant transmission power, smooth operation, and minimal noise. Crafted from premium 20CrMnTi material and treated with advanced heat processes, the gears boast exceptional wear and impact resistance. The lubrication system is an efficient blend of oil immersion and splash flow, maintaining ideal oil levels for optimal bearing lubrication. High-speed shaft entrances are fortified with skeleton or mechanical seals. After 8000 hours, the reducer's cover must be removed for seal inspection to determine replacement needs.
For maintenance ease, the lifting ring screw on the lid is solely for lid removal and not for gearbox lifting. Control instrument contact screw holes are strategically placed on the gearbox body, providing the flexibility to connect with control devices based on user specifications.
Our cooling tower-specific reducers primarily utilize vertical shaft gear transmissions, integrated with other transmission variants. The prominent product series include the M series and H series, ensuring versatility and adaptability in various applications.
Design Features:
· Ingenious design centered on fan performance parameters and specific operational requirements.
· Remarkable extended service life reaching up to 100,000 hours, boasting a service factor KA of 2.
· Comprehensive strength calculation and validation for gears, shafts, and other load-bearing components, coupled with in-depth bearing load capacity and life assessment.
· Innovative splash lubrication combined with a self-lubrication system for seamless operation.
· Our helical gears adhere to GB/T 3480 standards for involute gears strength calculation, while spiral bevel gears follow GB/T 10062 guidelines for load-capacity calculation of bevel gears.
· Adopts a forward-thinking modular design using diverse materials and standardized components to precisely cater to varying customer needs.
· Offers an optional sophisticated forced cooling system for maintaining precise oil temperature control even under the most extreme conditions.
Parameter
Reducer Technical Parameter
No. |
Model |
Nominal RPM |
Ratio |
Input RPM |
Power(kw) |
1 |
MSRD235 |
300 |
4.91 |
1480 |
45 |
220 |
4.42 |
980 |
30 |
200 |
4.91 |
980 |
30 |
2 |
MSRL200 (MSRL200A) |
265 |
5.6 |
1480 |
45 |
238 |
6.21 |
1480 |
45 |
200 |
4.77 |
980 |
30 |
210 |
4.62 |
980 |
30 |
191 |
5.08 |
980 |
30 |
173 |
5.6 |
980 |
30 |
156 |
6.21 |
980 |
30 |
3 |
MSRL250 (MSRL250A) |
165 |
8.97 |
1480 |
55 |
191 |
7.75 |
1480 |
55 |
214 |
6.91 |
1480 |
55 |
230 |
6.46 |
1480 |
55 |
251 |
5.89 |
1480 |
55 |
108 |
8.97 |
980 |
37 |
125 |
7.75 |
980 |
37 |
140 |
6.91 |
980 |
37 |
150 |
6.46 |
980 |
37 |
165 |
5.89 |
980 |
37 |
4 |
MSRL300 (MSRL300A) |
136 |
10.83 |
1480 |
160 |
145 |
10.13 |
1480 |
160 |
155 |
9.5 |
1480 |
160 |
184 |
8.04 |
1480 |
160 |
90 |
10.83 |
980 |
90 |
97 |
10.13 |
980 |
90 |
101 |
9.5 |
980 |
90 |
122 |
8.04 |
980 |
90 |
5 |
MSRL350A |
127 |
11.63 |
1480 |
160 |
136 |
10.95 |
1480 |
160 |
145 |
10.23 |
1480 |
160 |
155 |
9.68 |
1480 |
160 |
180 |
5.51 |
980 |
160 |
6 |
MSRL350D |
105 |
14.11 |
1480 |
200 |
117 |
12.52 |
1480 |
200 |
127 |
11.55 |
1480 |
200 |
7 |
MSRL400 |
101 |
14.63 |
1480 |
220 |
107 |
13.86 |
1480 |
250 |
116 |
12.78 |
1480 |
250 |
8 |
HSRL350 |
101 |
14.63 |
1480 |
185 |
107 |
13.86 |
1480 |
185 |
117 |
12.67 |
1480 |
200 |
127 |
11.75 |
1480 |
200 |
136 |
10.83 |
1480 |
200 |
9 |
HSRL400 |
101 |
14.63 |
1480 |
220 |
107 |
13.86 |
1480 |
250 |
116 |
12.78 |
1480 |
250 |
10 |
HSRL400T |
118 |
12.59 |
1480 |
200 |
Note:
1. The tables showcase a selection of our standard models, offering a glimpse into our capabilities. For those seeking tailor-made solutions, we are adept at providing bespoke configurations to meet your unique requirements.
2. Please note that the parameters indicated in these tables serve as a preliminary guide. For precise and authoritative specifications, we encourage consulting our official data sheets, expertly curated and issued by our technical department.
NEWIN Manufacturing Base

NEWIN FACTORY
Our expansive manufacturing base is strategically situated in the vibrant city of Huizhou, Guangdong, enveloping a sprawling area of 10,000 square meters, dedicated to innovation and precision.
ISO CERTIFICATION
We are proud holders of the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, underscoring our commitment to quality and sustainability.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Explore our cutting-edge Closed Type Cooling Tower Series, designed with precision and innovation to meet diverse cooling needs.
·
NSH/ NST Discover the versatile Open Type Cooling Tower Series, offering adaptability and high performance for a range of industrial applications.
·
NTG Introducing our robust and reliable Industrial Type Cooling Tower Series, engineered for durability and unwavering performance.
·
NECN/NECH Our high-efficiency Evaporative Condenser, designed to maximize cooling performance while minimizing environmental impact.
·
NWFL Advanced Dry Air Cooler, offering state-of-the-art cooling solutions to meet your demanding requirements.
At NEWIN, we pride ourselves on manufacturing and maintaining a comprehensive inventory of essential cooling tower accessories, crafted to impeccably cater to maintenance and replacement needs across a diverse range of sizes and types. Contact us to explore bespoke accessory customization tailored to your specific cooling tower requirements.
CONTAIN:
· Fan drive system (including fan, fan stack, reducer, motor, shaft, and more)
· Water distribution (featuring nozzles, drift eliminator, and more)
· Heat exchange (with PVC infills, cooling coil, and others)
· Other accessories (such as air inlet louver, valve, etc.)
Packaging & Shipping
Open type cooling towers shipment: Discover the pinnacle of precision and care with our open type cooling tower shipping services. Our team takes meticulous steps to prepare each unit, ensuring that it is dispatched in pristine condition, perfectly primed for easy installation and flawless operation upon arrival.
Closed type cooling towers shipment: Rely on our expertly orchestrated shipping solutions for closed type cooling towers. Our comprehensive process guarantees that your products are meticulously managed and delivered right on schedule, ensuring they reach your premises in perfect readiness, fully equipped to meet all your operational demands immediately.
Technical Strength& Standards


Certifications