Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE, ISO, CE
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material
  • Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material
  • Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material
  • Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material
  • Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material
  • Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material
Find Similar Products

Basic Info.

Model NO.
MBD
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Noise Level
Low
Application Fields
Industrial
Warranty
One Year
Usage
Cooling Tower
Application
Replace for Cooling Tower
Height
146mm
Transport Package
20/40/40hq Container with Loose Packing
Specification
CTI
Trademark
NEWIN
Origin
China
HS Code
84195000
Production Capacity
15000 Sets /Year

Product Description

Marley XCEL Eliminators Replace cellular Type 146mm Height PP/PVC Material 

NEWIN cooling tower drift eliminators

Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and losr velocity at impact on the blade walls and fall back into the tower.

MBD-146 Eliminator

Features
- Cellular design 

- Made of flame retardant pvc material
- Anti-aging, low airflow resistance, high strength
- Optimal droplet capture
- easy installation and long service life

Specification

Model--MBD PVC
Max.length depend on customer demand
Width depend on customer demand
Height 146 mm
Continuous
operation tempperature
50ºC
Max.applicationtemp.
(short term)
60ºC
Color Black
Application Marley cooling tower, counter flow cooling tower

Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container
Trade Terms: EXW, FOB, CFR,CIF, DDU.
Payment term: T/T, L/C, West Union
Minimum Order Quantity: 1000pcs

MBD drift eliminator Pictures --- cooling tower drift eliminator
Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material

Packing & Shipment
Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material


PVC Plastic sheet(after molding) Physical and mechanical property 
No. Item symbol unit index test method
1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008
2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91
    crosswise     ≥38.0  
3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91
    crosswise     ≥160  
4 Folded in half Coldness
Resistance Temperature
ordinary type tb ºC ≤-8 DL/T 742-2001
    Frigostabile type     ≤-18  
5 oxygen index OI -- ≥30 GB/T 2406 1-2008

Cooling tower plastic parts code and standard
GB/T 1033-1986 plastic density and relative density experiment method
GB/T 1040-1992 plastic tensile performance test methods
GB/T 1633-1979 thermoplastic softening point (d) test method
GB/T 1843-1996 plastic cantilever beam impact test method
GB/T 2406-1993 plastic combustion performance test method, oxidation index
GB/T 13022-1991 plastic film tensile performance test methods
GB/T 1190-1991 plastic rectangular tear performance test methods

Replacement for other brand cooling towers:

Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.
Marley Xcel Eliminators Replace Cellular Type 146mm Height PP/PVC Material

You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver,
please visit to below website below for more details. 
http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com
http://newinmachine.en.made-in-china.com







Contact person

Erin Lian
 
 
 *******************************************
 Website : http://newinmachine.en.made-in-china.com
                  http://newinmachine.en.made-in-china.com
                 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier