Introducing the Adiabatic Cooler NWFL-VA Series
Exquisite NWFL-VA Excellence Behold the NWFL-VA series, a cutting-edge V type dry air cooler meticulously crafted with an advanced Adiabatic Cooling System. Delivering unparalleled, efficient cooling all year round, it is the ultimate free cooling solution, ideal for data centers and a multitude of other facilities. Notably, it significantly minimizes water consumption, offering an exceptional alternative to traditional evaporative cooling methods.
Features
· Ingenious V type design combined with an innovative adiabatic cooling system,
Delivering exceptional cooling efficiency while maintaining impressively low water consumption.
· Crafted with optimally efficient components, such as the industry-leading EC motor,
Ensuring peak system efficiency coupled with outstanding energy savings.
· Generous redundancy options available,
Effectively eliminating any thermal performance degradation.
· High reliability seamlessly paired with easy maintenance protocols.
Working Principle
When the NWFL-VA adiabatic cooler springs into action:
An ingenious process begins: cold water cascades from the pinnacle of the cooler, meticulously distributing itself across the evaporative cooling pads. Meanwhile, revitalizing cool dry air is beckoned in by the efficient EC axial fan, sweeping over the pads and receiving a preliminary cooling touch. This adiabatic precooling of air significantly enhances the cooling capacity, brilliantly preparing it to chill the warm process fluid with remarkable efficiency.
Series |
Type |
Capacity |
1. Fan Drive System |
2. Heat Exchange System |
3. Adiabatic Pre-cooler |
NWFL-VA |
V |
Range |
EC axial fans |
Finned coil |
Evaporative cooling pads |
Maximum thermal performance |
300~1680kw |
Intelligent frequency conversion,
more energy saving |
Maximum heat transfer surface |
Precooling the ambient air temperature,
improving higer cooling efficency |
*4.The wake up is on the top of the pads can ensure the cool dry air in adiabatic precooling process when the pump is not running. |
*5. Recirculation system is designed for further reduce the total water consumption. |
Adiabatic cooling
system |
Exceeding 90% annual water saving compared to normal cooling tower |
Application |
Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc. |
Parameter
Model |
Configuration Mode |
Flow |
Cooling Capacity |
Dimension (mm) |
Nos of Fins |
Fan Diameter |
Power |
F/V |
m3/h |
kw |
L |
W |
T |
nos |
mm |
kw |
NWFL-300VA |
V |
52 |
300 |
4000 |
1290 |
198 |
2 |
EC900 |
7.6 |
NWFL-600VA |
V |
104 |
600 |
4000 |
1290 |
198 |
4 |
EC900 |
15.3 |
NWFL-520VA |
V |
90 |
520 |
4500 |
1786 |
198 |
2 |
EC800 |
12.6 |
NWFL-1040VA |
V |
180 |
1040 |
4500 |
1786 |
198 |
4 |
EC800 |
25.3 |
NWFL-600VA |
V |
105 |
600 |
4000 |
2280 |
198 |
2 |
EC900 |
15.3 |
NWFL-1200VA |
V |
210 |
1200 |
4000 |
2280 |
198 |
4 |
EC900 |
30.6 |
NWFL-840VA |
V |
144 |
840 |
5500 |
2777 |
198 |
2 |
EC900 |
19.1 |
NWFL-1680VA |
V |
288 |
1680 |
5500 |
2777 |
198 |
4 |
EC900 |
38.2 |
* Please note that this sample table only displays data available at the time of issue. For precise engineering purposes, kindly verify the detailed information with our sales team and engineers before proceeding with your purchase. Your accuracy is our priority.
* For multi-cell configurations, we encourage you to consult directly with the manufacturer to discover tailored solutions that best fit your needs. NEWIN retains the right to modify the parameters or dimensions in this table without prior notification, ensuring you always receive the most up-to-date technology.
Components& Options
· Heavy-duty Construction
Crafted with galvanized steel panels and fortified with NWN-Armour anti-corrosion coating, our heavy-duty construction boasts superior resistance akin to stainless steel. This robust design supports high concentration cycles, significantly reducing water consumption, and ensures durability even in challenging environments. Maintenance is a breeze, as the coating can be easily repaired if needed.
· V Type Finned Coil Heat Exchanger
Engineered for optimal performance, the V Type finned coil heat exchanger is a masterpiece of thermal efficiency. Constructed with precision-crafted copper tubes and aluminum fins, the adequate spacing guarantees superior heat transfer. The copper tubes are meticulously brazed to the coil headers and affixed to the finned coil via flaring, ensuring unmatched thermal continuity.
· EC Axial Fan
- The EC motor boasts a straight-shaft drive with an IP55 motor protection rating and F-class insulation, ensuring long-lasting performance in hot, humid environments. With energy efficiency reaching IE4 or higher, it's designed for excellence.
- Featuring tapered roller bearings, the fan showcases impressive load-bearing capabilities and longevity, with a service life exceeding 20,000 hours.
- Through comprehensive static and dynamic testing, the fan minimizes noise while optimizing heat exchange performance. With PFC technology, harmonics remain below 35%, maintaining high static efficiency even at low speeds.
· Adiabatic Pre-cooler
- Our evaporative cooling pads, crafted from impregnated cellulose cellular materials, are encased in robust stainless steel frames. The innovative design ensures thorough water distribution from the pad tops, maximizing cooling effectiveness.
- Enhanced with anti-UV treatment, the evaporative cooling pads are resilient and easily cleaned with a pressure washer, promising a long service life.
- Equipped with a water circulation pump, these pads effectively maintain design conditions even during peak summer heat.
· Adiabatic Intelligent Controls
- Intelligent frequency conversion in EC fans adapts to various site conditions, providing substantial energy savings.
- Ensures dry operation forcefully when water usage is restricted, maintaining optimal performance.
· Options
- Enhanced coil resistance capabilities for demanding environments
- Coil freeze-up safeguard for uninterrupted operation in cold climates
- Low noise upgrade for a quieter operation
- Increased redundancy for enhanced reliability. For any customized requirements, please contact a NEWIN sales representative.
NEWIN Manufacturing Base
NEWIN FACTORY
Our expansive manufacturing base is strategically located in the vibrant city of Huizhou, Guangdong, occupying a vast area of 10,000 square meters.
ISO CERTIFICATION
Proudly certified with ISO9001:2015 for outstanding Quality Management Systems and ISO14001:2015 for our commitment to superior Environmental Management practices.
WORKSHOPS
State-of-the-art Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Expert Cooling Tower Assembly Workshop
TESTING
Our Independent Testing LAB ensures rigorous quality control and product excellence.
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Innovative Closed Type Cooling Tower Series
·
NSH/ NST Efficient Open Type Cooling Tower Series
·
NTG Robust Industrial Type Cooling Tower Series
·
NECN/NECH High-performance Evaporative Condenser
·
NWFL Reliable Dry Air Cooler
NEWIN expertly manufactures and maintains a comprehensive inventory of cooling tower accessories, ensuring solutions to fit the maintenance and replacement needs of virtually any size and type of cooling tower. Reach out to us for customized accessory solutions.
CONTAIN:
· Fan drive system (including fan, fan stack, reducer, motor, shaft, etc.)
· Water distribution components (such as nozzles, drift eliminator, etc.)
· Heat exchange elements (including PVC infills, cooling coil, etc.)
· Additional accessories (such as air inlet louver, valve, etc.)
Packaging & Shipping
Open Type Cooling Towers Shipment: Experience the seamless delivery of our open type cooling towers, meticulously packaged to ensure they reach you in pristine condition. Trust in our reliable shipping processes to bring you excellence in cooling technology.
Closed Type Cooling Towers Shipment: Revel in the secure shipment of our closed type cooling towers, designed for maximum protection during transit. Rest assured, our packaging and shipping solutions prioritize the integrity and efficiency of your cooling needs.
Technical Strength& Standards
Certifications