Effective Water Trap Dust Collector for Cooling Tower Drift Control

Product Details
Customization: Available
Cooling Method: Cooling Tower
Certification: ISO, CE
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Effective Water Trap Dust Collector for Cooling Tower Drift Control
  • Effective Water Trap Dust Collector for Cooling Tower Drift Control
  • Effective Water Trap Dust Collector for Cooling Tower Drift Control
  • Effective Water Trap Dust Collector for Cooling Tower Drift Control
  • Effective Water Trap Dust Collector for Cooling Tower Drift Control
  • Effective Water Trap Dust Collector for Cooling Tower Drift Control
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Application
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
EVD
Condition
New
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Material
PVC
Application Fields
Cooling Tower
Height
145mm
Sheet Space
25 mm
Transport Package
20/40/40hq Container with Loose Packing
Specification
customized
Trademark
NEWIN
Origin
China
HS Code
3926901000
Production Capacity
1000000mt Per Year

Product Description

Introducing the Newin 145mm Series Cooling Tower PVC Drift Eliminator - your ultimate solution for superior cooling tower performance! Specially engineered by Newin (Guangdong) Machinery Co., Ltd., this product ensures exceptional drift control. Experience unparalleled efficiency and reliability in managing cooling tower emissions with the Effective Water Trap Dust Collector, designed to enhance your cooling tower operations.

Effective Water Trap Dust Collector for Cooling Tower Drift Control

Product Description

EVD Introducing the EVD series cellular drift eliminator, a remarkable innovation by Newin (Guangdong) Machinery Co., Ltd., designed to optimize performance and safety. This advanced system effectively captures and removes even the tiniest droplets of water that typically escape with exhaust air, reducing potential health risks and environmental nuisances. The innovative design of the EVD series drift eliminators features a complex labyrinth that significantly disrupts the airflow. As water droplets traverse this path, they are deftly redirected and collected on the walls, ensuring efficient coalescence and drainage back into the cooling tower's wet section, enhancing operational efficacy.



FEATURES

- Anti-aging construction, coupled with exceptional water absorption capabilities, ensures longevity and superior performance.
- Boasting low airflow resistance and robust high-strength, this product is engineered to perfection.
- Designed for effortless installation, the drift eliminator promises an extended service life, delivering value and reliability.
- Ingeniously versatile, it can seamlessly replace the air inlet louver, enhancing your system's adaptability.
Parameter

PROPERTIES

At Newin (Guangdong) Machinery Co., Ltd., we understand the diverse and unique needs of our clients. Our EVD drift eliminators are customizable with options in length, width, materials, thickness, and more. Simply provide us with your detailed specifications, and we will tailor the perfect solution for you. We are committed to meeting all customer requirements, ensuring high standards and satisfaction. Additionally, upon request, our fill media can be crafted in flame-retardant or anti-bacterial versions for enhanced safety and hygiene.
Module Length (Max)  mm 2440
Module Width  (Max)  mm 500
Module Depth   mm 145
Flute Height  mm 25
Flute Corrugation Angle  degrees -
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.4
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - High temp.  °C 80
Customized size and thickness available for special request. Contact Newin for details.
 


STRUCTURE & INSTALLATION DRAWING

To ensure a seamless experience, Newin provides comprehensive structure and installation drawing advice, along with guidance on jobsite storage. Our commitment to quality is reflected in the quality control report that accompanies each shipment, drawing attention to crucial details for when our valued customers receive their materials. Should you have unique specifications, our OEM services and special mold design options are readily available upon request.
Effective Water Trap Dust Collector for Cooling Tower Drift Control
Application

APPLICATION & USAGE

Introducing the Newin EVD Cellular Drift Eliminator This remarkable component adheres to SGS testing under ASTM Standards, ensuring premium quality and exceptional efficiency for your cooling tower. Simply share the model or size of your tower with us, and we will expertly calculate the precise number of sheets required for your cooling tower replacement.Effective Water Trap Dust Collector for Cooling Tower Drift Control
 

APPLICABLE COMMERCIAL STANDARDS

The sheet material meticulously complies with SGS testing, following ASTM standards. Testing is available for each property, or collectively, as per your product requirements.
Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.

ESSENTIAL DATA FOR CELLULAR DRIFT ELIMINATOR REPLACEMENT

Provide the measurement details below to meet your cooling tower maintenance or repair project needs. For supreme quality and dependability, trust Newin. Whether it's a site visit or maintenance service, our solutions are precisely engineered to fit your cooling tower fills and components seamlessly.

Effective Water Trap Dust Collector for Cooling Tower Drift Control
Options

Introducing the Newin cooling tower drift eliminator - a groundbreaking solution engineered to maximize efficiency and performance in cooling towers. This innovative product, crafted with precision, is built to seamlessly enhance airflow, ensuring optimal function and reliability. With the Newin cooling tower drift eliminator, experience unmatched durability and unparalleled quality that sets new standards in the industry.
Effective Water Trap Dust Collector for Cooling Tower Drift Control

NEWIN Manufacturing Base

Effective Water Trap Dust Collector for Cooling Tower Drift Control
NEWIN FACTORY
Embark on a captivating journey to our cutting-edge manufacturing base, strategically located in the bustling industrial hub of Huizhou, Guangdong. Spanning an impressive 10,000 square meters, this facility is a shining example of innovation, excellence, and advanced technology.

ISO CERTIFICATION
Our steadfast dedication to supreme quality and environmental responsibility is proudly highlighted by our renowned ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification.

WORKSHOPS
State-of-the-Art Welding Workshop
Sophisticated Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Integrated Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing Laboratory

Effective Water Trap Dust Collector for Cooling Tower Drift Control
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unparalleled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously crafted to provide superior performance and unmatched reliability.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered to ensure optimal operation and robust performance, setting industry benchmarks.
· NTG Explore the exceptional capabilities of our Industrial Type Cooling Tower Series, specifically designed to tackle heavy-duty and demanding applications, ensuring resilience and power.
· NECN/NECH Seamlessly integrate advanced efficiency with our cutting-edge Evaporative Condenser models, setting new standards in performance and operational excellence.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every aspect of cooling.

Effective Water Trap Dust Collector for Cooling Tower Drift Control
NEWIN is your trusted partner in premium cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Customize your selection to fit a wide array of cooling tower sizes and types. Contact us to tailor the perfect suite of accessories for your cooling tower.

CONTAIN:
· A durable Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for precision and longevity.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators, delivering superior performance.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for peak performance and energy efficiency.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system and enhance overall functionality and efficiency.
Packaging & Shipping

Open type cooling towers shipment: Uncover the unparalleled care and precision that defines the packaging of our expertly engineered open-type cooling towers. Each unit is carefully enveloped in superior, high-grade materials using strategic packing techniques. This guarantees that these advanced units arrive at your destination in immaculate, flawless condition. By prioritizing safety and security, we eliminate any potential for transit damages, offering you complete peace of mind. With our streamlined logistics and reliable delivery service, your cooling solutions are ready to perform from day one. Experience the outstanding power and efficiency of our products immediately, assured that every detail has been meticulously managed with consummate professionalism.

Effective Water Trap Dust Collector for Cooling Tower Drift Control
Closed type cooling towers shipment: Revel in unmatched assurance with our sturdy, expertly designed packaging solutions, crafted specifically for closed-type cooling towers. Each unit is meticulously and securely encased to endure the rigors of transport, ensuring they arrive at your facility unscathed and ready for optimal performance. Our steadfast commitment to superior quality control and prompt delivery allows you to concentrate on what truly matters - leveraging the remarkable advantages of our state-of-the-art cooling technology in your applications. Embrace seamless operation without any stress or concern, confident that your solutions will arrive intact and on schedule, underpinned by our relentless pursuit of excellence.
Effective Water Trap Dust Collector for Cooling Tower Drift Control
Effective Water Trap Dust Collector for Cooling Tower Drift Control
Technical Strength& Standards

Effective Water Trap Dust Collector for Cooling Tower Drift Control
Effective Water Trap Dust Collector for Cooling Tower Drift Control

Certifications

Effective Water Trap Dust Collector for Cooling Tower Drift ControlEffective Water Trap Dust Collector for Cooling Tower Drift ControlEffective Water Trap Dust Collector for Cooling Tower Drift ControlEffective Water Trap Dust Collector for Cooling Tower Drift Control

Effective Water Trap Dust Collector for Cooling Tower Drift Control

 


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More