Mixed Flow Evaporative Fluid Coolers, Are Used for Heating, Ventilation, Air-Conditioning, and Light to Medium Processing Applications

Cooling Method: Counter Flow
Ventilation Mode: Mechanical Ventilation
Material: FRP
Air Contact Form: Wet
Air Contact Way: Open
Tower Shape: Square
Customization:
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
LKH
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, ISO
Condition
New
Nominal Flow
80-1000 M³/H
Usage
for Manufacture
Wet Bulb Temperature
28 Deg.C
Transport Package
20/40/40hq Container with Loose Packing
Specification
customized
Trademark
NEWIN
Origin
China
HS Code
841950
Production Capacity
15000 Sets/ Year

Product Description

Mixed Flow Evaporative Fluid Coolers, are used for heating, ventilation, air-conditioning, and light to medium processing applications
Mixed Flow Evaporative Fluid Coolers, Are Used for Heating, Ventilation, Air-Conditioning, and Light to Medium Processing Applications

LKH series cross flow square cooling tower is available in capacity for single cell from 100 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements.This cooling tower is highly used in heating, ventilation, air-conditioning, and light to medium processing applications.


Features
-  Factory assembled, convenient transportation and installation
-  Excellent heat exchange performance 
-  Easy maintenance without stop working 
-  Small cover area, low comprehensive investment
-  Energying saving and environment friendly

 

Mixed Flow Evaporative Fluid Coolers, Are Used for Heating, Ventilation, Air-Conditioning, and Light to Medium Processing Applications
Components Instruction

AXIAL FLOW FAN

Uses cooling tower special aluminum alloy axial flow fan,forward type blade structure design, small wind resistance, big air volume, low noise, good performance, high efficiency. Streamline high strength fan stack gurantees airflow uniform through the fan inlet and outlet area, maximum reduce the energy comsuption. Fan motor's protection class: IP55, Insulation class: F class.

 

COOLING COIL

Cooling coils as the core parts of closed cooling tower, are maded up of great quality copper coil or steel coil. Coil inside is through cooling medium, outside is cooled by water spray to meet the cooling requirement.
Steel coils (G type) are used by high quality Ф25 mm seamless fluid tube, and processed by H.D.G.(hot dip galvanised) to enhance the coil pipe anti-corrosion ability, extend service life.
Copper coils (T type) are used by T2 deoxidized acid copper tube, silver electrode is used to connect between the copper pipe and elbow welding, low solder joint and good quality, design pressure is 1.2MPa.

 

ALUMINIUM ZINC PLATE

Shell plate uses imported aluminium zinc plate, which is one of the strongest corrision resistance plate, service life is 3-6 times of ordinary galvanized sheet, with strong termal resistance, high heat resistance, beautiful appearance, ect.

 

SPRAY PUMP

Used great mechanical seal to prevent from the leakage, made by dedicated outdoor motor, and special configuration imported bearings, to ensure that the fan, water pump has long term reliable operation, low power, large flow, low noise, excellent performance, etc. The pump body is precision casting, strong and long service life.

 

DRIFT ELIMINATOR

Original detachable eliminator adopts good performance PVC material, its special structure could change the air flow direction, effectively remove from the wet air moisture in the air, redeased the drift loss below 0.001%, maximum save the water, what's more, to make sure the area around cooling tower no pollution, and prevent from the germs spreading.

 

HIGH EFFICIENCY FILM FILLS

Hanging film type fill which spreads the water into a thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow. It incorporates highly efficient cellular eliminators and louvers, integrally molded within the fill sheets, preventing water from escaping and assuring precise air distribution throughout wide variations in airflow. Unlike towers equipped with separate external louvers, this fill operates virtually icefree even in extremely cold weather.

 

ADVANCED WATER DISTRIBUTION SYSTEM

The spray system uses in a variety of high flow rate and anti clogging basket type nozzles, to ensure the continuous uniform water spraying on the surface of the coil. Under the help of induced air, water can cover all the coils to the utmost extent to do the complete heat exchage among water, air and refrigerant. In this case, heat transfer efficiency will increase dramatically. The nozzle is connected on spray pipe branch. When cleaning, the nozzles and spray pipe branch can be easily dismounted.

Technical Specification of LKH Series Cooling Tower

Item Water
 Flow 
(m3/h)
Dimension (mm)         Fan Spray Pump Inlet/Outlet 
Pipe 
Diameter
 (mm)
Weight (kg)
 Model Length Width Height Air 
Volume
(m³/h)
Power 
(Kw)xQty
Flow 
(m³/h)
Power 
(Kw)
Dry Wet
LKH-30 30 2500 1970 2263 32000 1.1*2 32.5 1.5 80 T:850 3100
2550 1970 2263 G:930 3230
LKH-40 40 2500 1970 2263 32000 1.1*2 32.5 1.5 80 T:900 3200
2550 1970 2263 G:1080 3420
LKH-50 50 3100 1970 2395 48000 1.1*3 45 2.2 80 T:1160 3820
3160 1970 2395 G:1280 3940
LKH-60 60 3100 1970 2395 48000 1.1*3 45 2.2 80 T:1250 3950
3160 1970 2395 G:13900 4100
LKH-70 70 3100 1970 2890 48000 1.1*3 58 2.2 100 T:1320 4090
3160 1970 2890 G:1500 4310
LKH-80 80 3100 1970 2890 48000 1.1*3 58 2.2 100 T:1460 4230
3160 1970 2890 G:1610 4400
LKH-100 100 3100 1970 2890 48000 1.1*3 58 2.2 100 T: 1630 4420
3160 1970 2890 G:1800 4590
LKH-125 125 3840 2340 3120 64000 1.1*4 89 4 125 T: 1870 5820
4600 2340 3120 G:2040 5990
LKH-150 150 4350 2340 3645 80000 1.5*4 100 5.5 150 T: 2130 6560
5220 2340 3645 G:2350 6780
LKH-175 175 4350 2340 3645 80000 1.5*4 130 5.5 150 T:2400 6780
5220 2340 3645 G:2580 6960
LKH-200 200 4350 2340 3645 80000 1.5*4 130 5.5 150 T:2650 6930
5220 2340 3645 G:2820 7120
LKH-250 250 5630 2340 3890 120000 2.2*4 172 7.5 200   T:2920 8630
6760 2340 3890   G:3200 9110



Mixed Flow Evaporative Fluid Coolers Draing
Mixed Flow Evaporative Fluid Coolers, Are Used for Heating, Ventilation, Air-Conditioning, and Light to Medium Processing Applications

Optional Accessories

♦ Noise reduction upgrade                      ♦ Anti-Freeze heater
♦ Vibration isolator                                   ♦ Stainless steel casing and framework / bolts and nuts (304 / 316)
♦ High-temperature upgrade                   ♦ Dual-speed Motor & VFD motorAnti-Freeze heater

Mixed Flow Evaporative Fluid Coolers, Are Used for Heating, Ventilation, Air-Conditioning, and Light to Medium Processing Applications

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now