Forced Draft Cooling Tower for Enhanced Performance and Reliability

Product Details
Customization: Available
After-sales Service: Consult Newin Sales Representative
Warranty: Consult Newin Sales Representative

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Forced Draft Cooling Tower for Enhanced Performance and Reliability
  • Forced Draft Cooling Tower for Enhanced Performance and Reliability
  • Forced Draft Cooling Tower for Enhanced Performance and Reliability
  • Forced Draft Cooling Tower for Enhanced Performance and Reliability
  • Forced Draft Cooling Tower for Enhanced Performance and Reliability
  • Forced Draft Cooling Tower for Enhanced Performance and Reliability
Find Similar Products
  • Overview
  • Product Description
  • Advantages
  • Components
  • Reference Projects
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
NCFN-GS
Cooling Method
Dry Wet Hybrid Cooling
Ventilation Mode
Forced Draft
Material
Aluminum Zinc
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ordinary
Application Fields
Industial & Air Conditioning
Certification
ISO, CE, CTI
Condition
New
Model
Ncfn-GS-L-850/1150/1300
Cooling Capacity
863kw to 1793kw
Free Cooling
Capacity 120kw to 247kw ( Under 12/7/0 Celsius)
Fan Motor Without Silencer
11kw to 37kw
Transport Package
Container
Specification
CE, UL, CTI
Trademark
NEWIN
Origin
Shenzhen China
HS Code
84195000
Production Capacity
1000sets/Month

Product Description

Introducing the Advanced Dry Wet Hybrid Cooling Tower - a state-of-the-art solution engineered for superior heat dissipation efficiency. Designed to seamlessly integrate cutting-edge technology with robust functionality, this cooling tower optimizes performance and ensures consistent reliability. Experience unparalleled thermal management that caters to your cooling needs with precision and innovation.

Forced Draft Cooling Tower for Enhanced Performance and Reliability
Product Description

NCFN-GS Series Dry-Wet Hybrid Forced Draft Closed Cooling Tower

The NCFN-GS series cooling system ingeniously combines the best of both wet and dry cooling technologies. This integration ensures unparalleled cooling efficiency, reduced energy usage, and significant water savings, adapting seamlessly to a range of ambient temperatures. Perfectly engineered for arid desert expanses and severe cold environments, it excels even under the toughest conditions. Moreover, its forced draft mechanism ensures ultra-quiet operation, establishing it as the ideal cooling choice for areas with limited ventilation and stringent noise restrictions.
Forced Draft Cooling Tower for Enhanced Performance and Reliability

Advantages

ADVANTAGE

Forced Draft Cooling Tower for Enhanced Performance and Reliability

Dry-Wet Hybrid Cooling Mode

The NCFN-GS cooling tower is ingeniously designed to seamlessly adapt its operational modes to the ever-changing ambient temperature, ensuring optimal performance at all times.

Dry Cooling Mode
When temperatures dip below -10ºC or the output temperature falls under the desired set point, the spray pump ceases operation. This transition to dry cooling mode minimizes water evaporation during the chilly seasons, allowing for the provision of ice water under certain conditions. It serves as a prudent refrigeration alternative, offering remarkable water and energy savings.

Wet Cooling Mode
Once the temperature climbs beyond a specific threshold (-2ºC), or when the output temperature overshoots the predetermined level, the spray pump springs into action, transitioning the cooling tower to an efficient wet cooling mode. The result is robust evaporative cooling that ensures substantial cooling capacity, even during the warmest conditions.

 

Water saving, Energy conservation, Environmental protection

> Compared to traditional wet cooling towers, this innovative system significantly curtails spray water usage, leading to an impressive reduction in overall water consumption.
> With the integration of intelligent control systems and cutting-edge cooling technology, the tower enhances energy efficiency, resulting in substantial electricity savings and a notable decrease in energy consumption.
> The dry-wet hybrid cooling mode adeptly minimizes water mist emissions, reducing the environmental footprint while boosting eco-friendliness.

Forced Draft Cooling Tower for Enhanced Performance and Reliability

Forced Draft Cooling Tower for Enhanced Performance and Reliability

Operation & Maintenance Cost Saving

> The closed-circuit circulation system ensures the purity of the cooling medium, which significantly cuts down on water contamination and lowers water treatment costs. Additionally, the winter utilization of dry cooling mode greatly diminishes the risk of component freezing, thereby reducing equipment operation and maintenance expenses, while ensuring long-term stability and reliability of the equipment.
> With factory assembly, transportation, and installation are streamlined and efficient, ultimately conserving valuable time and effort.


Components

MAIN PARTS

Forced Draft Centrifugal Fan Drive System

Introducing our state-of-the-art centrifugal fan, a masterpiece of engineering excellence, proudly bearing the prestigious AMCA Seal. This fan excels in air performance, sound quality, and Fan Efficiency Grade (FEG). Equipped with precisely designed wheel blades and a belt pulley drive, it has passed stringent static and dynamic balancing tests, achieving the highest G2.5 grade balancing standard. This ensures your cooling tower operates with superior heat transfer capabilities and whisper-quiet noise levels. Boasting a vast air volume capacity, it supports a flow range from 1000m3h to an impressive 100000m3h. Experience the unmatched benefits of this system, including exemplary stability, extraordinary efficiency, ultra-low noise, and reduced energy consumption.

Forced Draft Cooling Tower for Enhanced Performance and Reliability

Key Parts for Closed Circuit System And Dry-Wet Cooling Modes.

The high-efficiency cooling process begins as the fluid medium traverses through the
fin tube heat exchanger and stainless steel heat exchange coil within the closed circuit system, ensuring pristine conditions, minimizing water treatment costs, and reducing maintenance demands. This not only preserves precious water resources but also offers an efficient cooling solution.

Fin tube heat exchanger and stainless steel heat exchange coil are central not only to closed circuit systems but also serve as key components in Dry-Wet cooling modes.
 

Forced Draft Cooling Tower for Enhanced Performance and Reliability

Finned Tube Heat Exchanger

Crafted with precision, the fin tube heat exchanger utilizes stainless steel tubes paired with aluminum spiral fins. Its robust anti-corrosion attribute and enhanced stability are unparalleled. Designed with a focus on augmenting the heat exchange area, it optimizes heat transfer efficiency and promotes full air interaction with the fin tube. This facilitates water-saving operations during both dry and wet cooling phases. Remarkably, it also prevents the occurrence of "white smoke" during the winter, ensuring a superior working environment for the equipment and significantly extending its lifespan.

 


Stainless Steel Heat Exchange Coil

Our premium heat exchange coil features a stainless steel serpentine bending tube coupled with a robust framework, delivering exceptional thermal performance. It ensures complete contact with spray water for outstanding heat exchange and optimal cooling results. These stainless steel pipes offer superior corrosion resistance, and are also lightweight and fully recyclable, making them an eco-friendly choice.

Forced Draft Cooling Tower for Enhanced Performance and Reliability

Forced Draft Cooling Tower for Enhanced Performance and ReliabilityOptional Various Additional Functions
Enhance your system with our optional features, including a Two-speed & VFD variable frequency motor, Vibration Cut-off Switch, Electronic descaler, Water treatment equipment, Anti-freeze automatic heating system, Noise reduction upgrades, and an External maintenance platform with guardrail/Installation and maintenance boom, among others.
 

Cost-effective Anti-Corrosion Solution
NWN-Armour Anti-corrosion Technology

Our innovative NWN-Armour coating offers remarkable corrosion resistance, rivaling the resilience of stainless steel. It stands as a budget-friendly alternative to traditional stainless steel solutions.
Forced Draft Cooling Tower for Enhanced Performance and Reliability
Reference Projects

Forced Draft Cooling Tower for Enhanced Performance and Reliability

Product Parameters

Forced Draft Cooling Tower for Enhanced Performance and Reliability

Model Wet Cooling Free Cooling Fan Motor Spray Pump Total Dimension
(without silencer)
Weight
Fluid flow Cooling capacity Capacity
12/7/0ºC
Power Power L W H Shipping Operation
m³/h kW kW kW kW mm mm mm kg kg
NCFN-GS-L-510-F 66 340 77 5.5  2.2  4680 2200 2920 3468 5184
NCFN-GS-L-510-S 66 340 108 7.5  2.2  4680 2200 3040 3636 5421
NCFN-GS-L-640-S 97 499 111 7.5  2.2  4680 2200 3240 3908 5812
NCFN-GS-L-640-E 97 499 142 11.0  2.2  4680 2200 3360 4082 6041
NCFN-GS-L-1000-F 119 612 139 15.0  4.0  6920 2200 2990 5438 8061
NCFN-GS-L-1000-S 119 612 211 18.5  4.0  6920 2200 3110 5647 8213
NCFN-GS-L-1250-S 175 900 218 22.0  4.0  6920 2200 3310 5898 8698
NCFN-GS-L-1250-E 175 900 273 30.0  4.0  6920 2200 3430 6107 9019
NCFN-GS-L-1560-F 225 1158 206 37.0  5.5  7520 2400 3190 6291 9928
NCFN-GS-L-1560-S 225 1158 273 37.0  5.5  7520 2400 3310 6534 10311
NCFN-GS-L-1560-E 225 1158 273 45.0  5.5  7520 2400 3430 6777 10694
Note:
1. Standard Design Working Condition: Fluid in/out temperature: 35/30ºC.
2. Standard design ambient wet/dry bulb temperature: 21/31ºC.
3. Above data sheet based on 40% ethylene glycol solution fluid.
4. Please contact NEWIN sales representative if working condition not same as above standard design condition.

 

NEWIN Manufacturing Base

NEWIN FACTORY: The Hub of Excellence Our state-of-the-art facility sprawls over an impressive area exceeding 10,000 square meters.

Cooling Tower Workshops: Featuring dedicated sheet-metal, precision welding, advanced heat exchange coil, and comprehensive cooling tower assembly workshops.
Cooling Tower Infills Workshops: Specialized Fills production and Adhesive workshop area.


NEWIN COOLING TOWERS: Superior Quality and Performance

· NWN/ NWF/ NCFN - Closed Type Cooling Tower Series: Engineered for Maximum Efficiency Closed Type Cooling Tower Series
· NSH/ NST - Open Type Cooling Tower Series: Designed for Optimal Cooling Open Type Cooling Tower Series
· NTG - Industrial Type Cooling Tower Series: Robust and Reliable Industrial Type Cooling Tower Series
· NECN/NECH - Evaporative Condenser: Cutting-Edge Technology Evaporative condenser
· NWFL - Dry Air Cooler: Advanced Cooling Solutions Dry Air Cooler

NEWIN manufactures and maintains a comprehensive inventory of all major cooling tower accessories, catering to the maintenance and replacement requirements of virtually any size and type of cooling tower. Please reach out to customize the cooling tower accessories tailored to your needs.

CONTAIN: Comprehensive Solutions for All Needs
· Fan drive system: Including fan, fan stack, reducer, motor, shaft, and more.
· Water distribution: Featuring precision-engineered nozzles and efficient drift eliminators.
· Heat exchange: Utilizing high-quality PVC infills and innovative cooling coils.
· Other accessories: Air inlet louvers, valves, and additional essential components.

Forced Draft Cooling Tower for Enhanced Performance and Reliability
Packaging & Shipping

Open Type Cooling Towers Shipment - Ensuring Safe and Efficient Transit

Forced Draft Cooling Tower for Enhanced Performance and Reliability
Closed Type Cooling Towers Shipment - Dependable and Secured Freight Handling
Forced Draft Cooling Tower for Enhanced Performance and Reliability
Forced Draft Cooling Tower for Enhanced Performance and Reliability
Forced Draft Cooling Tower for Enhanced Performance and Reliability

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More