Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

Product Details
Customization: Available
After-sales Service: Consult Newin Sales Representative
Warranty: Consult Newin Sales Representative

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
  • Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
  • Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
  • Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
  • Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
  • Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
Find Similar Products
  • Overview
  • Features
  • Product Parameters
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWN-GS
Cooling Method
Dry Wet Hybrid Cooling
Ventilation Mode
Induced Draft
Air Contact Form
Wet and Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industial & Air Conditioning
Certification
ISO, CE, CTI
Condition
New
Model
Nwn-GS
Cooling Capacity
52kw to 1545kw
Free Cooling
Capacity 9.1kw to 239.7kw ( Under 12/7/0 Celsius)
Transport Package
Container
Trademark
NEWIN
Origin
Shenzhen China
HS Code
84195000
Production Capacity
1000sets/Month

Product Description

Experience unmatched efficiency with our remarkable Advanced Dry Wet Hybrid Cooling Tower, designed specifically for superior heat dissipation.
This innovative solution seamlessly integrates dry and wet cooling technologies, ensuring your system operates with peak effectiveness and reliability. Elevate your operations with top-tier cooling performance that sets the standard for energy efficiency and environmental responsibility.

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
Features
NWN-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower

The cooling system of NWN-GS series integrates the attributes of wet and dry cooling, delivering optimal cooling performance, minimal energy consumption, and water conservation across varying ambient temperatures. It is particularly well-suited for arid desert regions and harsh cold climates. Additionally, its forced draft system allows the low-noise operation and represents the optimal cooling solution for inadequately ventilated and noise-sensitive locations.
Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

ADVANTAGE
 
Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

Dry-Wet Hybrid Cooling Mode

NWN-GS cooling tower has the capability to adapt its operational modes in response to fluctuations in ambient temperature.

Dry Cooling Mode
When the temperature falls below -10ºC or the output temperature is lower than the set point, the spray pump will cease operation and the cooling tower will switch to dry cooling mode. This minimizes water evaporation during cold seasons and provides ice water in certain working conditions as an alternative to refrigeration, resulting in water and energy savings.

Wet Cooling Mode
When the temperature exceeds a specific threshold (-2ºC), or when the output temperature surpasses a predetermined level, the spray pump initiates operation, causing the cooling tower to function in wet cooling mode. Evaporative cooling guarantees substantial cooling capacity.


 

Minimized Water Contamination, High Thermal Efficiency, Reduced Operational Expenditure.

 

The counter-flow closed-loop cooling system maintains optimal heat transfer efficiency while ensuring pure media protection, substantially reducing both environmental contamination potential and operational water treatment costs.

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

Wide application range with exceptional scenario compatibility.

 

This system is ideally suited for industries with stringent cooling water quality requirements (e.g., electronics, pharmaceuticals), precise temperature control needs (e.g., chemical process cooling), or restricted water discharge capabilities-effectively mitigating the contamination risks associated with open-loop cooling. It maintains high heat dissipation efficiency even in hot/humid climates while significantly reducing water consumption and freeze damage in cold/arid regions. Particularly well-adapted to diverse climate zones like Northern China, it delivers reliable performance across extreme environmental conditions.



MAIN PARTS
 

 

High Efficient Axial Flow Fan

> Utilization of the cooling tower special aluminum alloy axial flow fan, forward type blade structure design, small wind resistance, big air volume, low noise, good performance, high efficiency.

> Streamline high-strength fan stack ensures airflow uniform through the fan inlet and outlet area, maximum reduce the energy consumption.

> Fan motor's protection class: IP55, Insulation class: F class. Options: Two-speed, VFD or anti-explosion motor.

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage


Key Parts for Closed Circuit System And Dry-Wet Cooling Modes.

The fluid medium needing cooling gracefully circulates through the
fin tube heat exchanger and stainless steel heat exchange coil within the closed circuit system, maintaining cleanliness, reducing water treatment and maintenance costs, and conserving valuable water resources while ensuring efficient cooling.

Fin tube heat exchanger and stainless steel heat exchange coil are not only quintessential components of closed circuit systems, but also The key elements of dry-wet cooling modes are the cornerstone of our innovative cooling technology.
 

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

Finned Tube Heat Exchanger

Our fin tube heat exchanger is crafted using stainless steel tubes intertwined with aluminum spiral fins. This construction not only ensures remarkable anti-corrosion properties but also provides unmatched stability, making it a preferred choice.. The strategic design of our fin tube significantly amplifies the heat exchange area, optimizing thermal transfer efficiency. It facilitates complete air interchange with the fin tube, effectively allowing the equipment to operate in a water-saving mode during both dry and wet cooling phases, delivering superior performance. Moreover, it adeptly eradicates the emergence of "white smoke" during winter operations, thus maintaining an optimal environment for equipment longevity and operational excellence.

 


Stainless Steel Heat Exchange Coil

Our premium heat exchange coil is engineered with a stainless steel serpentine bending tube, seamlessly integrated with a robust framework. This combination guarantees exceptional thermal performance, ensuring full interaction with spray water for unparalleled heat exchange and cooling effectiveness. The stainless steel heat exchange pipes are engineered to be not only corrosion-resistant but also lightweight and recyclable, enhancing sustainability and durability.

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
 
Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

PLC Electrical Control System

 

Automated operation is achieved through intelligent control systems, further reducing operation and maintenance costs

 

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
Optional Various Additional Functions
· Vibration Cut-off Switch
· Electronic descaler
· Water treatment equipment
· Anti-freeze automatic heating system
 

Cost-effective Anti-Corrosion Solution
NEWIN NWN-Armour Anti-corrosion Technology

Products coated with NWN-Armour anti-corrosion coating exhibit outstanding resistance to corrosion, approaching the qualities of stainless steel. They serve as a cost-effective alternative to stainless steel.
Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

 

Product Parameters
Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
Model Wet Cooling Free Cooling Fan Motor Spray Pump Total Dimension Weight
Fluid Flow Cooling Capacity Cooling Capacity Power Power L W H Shipping Operation
m³/h kW kW kW kW mm mm mm kg kg
NWN-GS-60-Z7-S 10 52  9.1  1.1*1 0.75 1800 900 3480 760 1180 
NWN-GS-90-Z7-S 15 77  9.4  1.5*1 0.75 1800 900 3480 810 1230 
NWN-GS-120-Z7-S 20 103  17.8  1.1*2 0.75 2300 1100 3320 1030 1810 
NWN-GS-180-Z7-S 30 155  22.8  1.5*2 1.1 2850 1100 3370 1320 2260 
NWN-GS-230-Z7-S 40 206  31.1  2.2*2 1.1 2850 1100 3580 1420 2460 
NWN-GS-290-Z7-S 50 258  31.9  3*2 1.1 2850 1100 3580 1520 2560 
NWN-GS-350-Z7-S 60 309  34.6  3*2 1.1 2850 1200 3740 1690 2880 
NWN-GS-450-Z7-S 80 412  74.4  3*3 2.2 4600 1450 3940 3290 4600 
NWN-GS-600-Z7-S 100 515  76.9  4*3 2.2 4600 1450 3940 3490 4900 
NWN-GS-750-Z7-S 125 644  94.8  7.5*2 2.2 4650 1750 4410 4100 6160 
NWN-GS-850-Z7-S 150 773  124.4  7.5*2 3 4650 2250 4540 4700 7440 
NWN-GS-1000-Z7-S 175 901  125.7  7.5*2 3 4650 2250 4710 4900 7740 
NWN-GS-1150-Z7-S 200 1030  171.9  11*2 5.5 6200 2250 4820 6030 10210 
NWN-GS-1300-Z7-S 225 1159  175.2  11*2 5.5 6200 2250 4820 6230 10510 
NWN-GS-1450-Z7-S 250 1288  197.2  15*2 5.5 6250 2500 5080 6780 11620 
NWN-GS-1750-Z7-S 300 1545  239.7  15*2 7.5 6250 3000 5180 7740 13510 
Note:
1. Standard Design Working Condition: Fluid in/out temperature: 35/30ºC.
2. Standard design ambient wet/dry bulb temperature: 21/31ºC.
3. Above data sheet based on 40% ethylene glycol solution fluid.
4. Please contact NEWIN sales representative if working condition not same as above standard design condition.
NEWIN Manufacturing Base

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
NEWIN FACTORY
Nestled in the vibrant Huizhou, Guangdong, our expansive manufacturing base spans an impressive 10,000 square meters, offering a state-of-the-art environment for innovation and production excellence.

ISO CERTIFICATION
Boasting prestigious ISO certifications, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin exemplifies a commitment to superior quality and sustainable practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Cutting-edge Closed Type Cooling Tower Series engineered for optimal performance.
· NSH/ NST Highly efficient Open Type Cooling Tower Series designed for diversified applications.
· NTG Robust Industrial Type Cooling Tower Series tailored for demanding environments.
· NECN/NECH Sophisticated Evaporative Condenser systems that deliver superior cooling efficiency.
· NWFL Innovative Dry Air Cooler solutions offering high-capacity, energy-efficient performance.

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
NEWIN provides a comprehensive inventory of premium cooling tower accessories, catering to maintenance and replacement demands across a variety of cooling tower sizes and types. Reach out to us to tailor the precise cooling tower accessories you require.

CONTAIN:
· Fan drive system components including fan, fan stack, reducer, motor, and shaft, expertly crafted to enhance functionality.
· Water distribution elements like nozzles and drift eliminators, designed for optimal fluid management.
· Heat exchange components such as PVC infills and cooling coils, ensuring efficient thermal transfer.
· Additional accessories including air inlet louvers and valves, meticulously engineered for seamless integration.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Experience seamless transit with our expertly coordinated shipping solutions, ensuring your equipment arrives on time and in pristine condition.

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
Closed Type Cooling Towers Shipment: Discover the assurance of secure and efficient delivery, with our meticulous handling process safeguarding your valuable assets throughout their journey.
Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
Technical Strength& Standards

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage
Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

Certifications

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial UsageNwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial UsageNwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial UsageNwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

Nwn-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower for Industrial Usage

 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More