Efficient Air Inlet Louver Designed for Wet and Dry Air Contact

Product Details
Customization: Available
Cooling Method: Cross Flow, Cooling Tower
Certification: ISO, CE, ISO, CE, SGS
Still deciding? Get samples of $ !
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
  • Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
  • Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
  • Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
  • Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
  • Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
Find Similar Products
  • Overview
  • Features
  • Parameter
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NAL Series
Condition
New
Ventilation Mode
Mixing Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Ordinary
Material
PVC
Application Fields
Cross Flow Cooling Tower
Model--Lah
PVC
Size
65/70thicknessx Any Length X Any Width
Continuous Operation Tempperature
50 Degree Centigrade
Max.Applicationtemp. (Short Term)
60 Degree Centigrade
Color
Black
Corrugation Height
18 mm
Thickness
65/70mm
Application
Cross Flow Square Cooling Tower
Transport Package
20/40/40hq Container with Loose Packing
Specification
65/70mm thickness
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

PVC Material Cooling Tower Fill Nal Air Inlet Louver

NAL series Newin NAL series air inlet louver is meticulously crafted from high-strength PVC sheets, expertly bonded for enhanced durability. The robust surrounding frame is available in your choice of galvanized steel or stainless steel, ensuring maximum resilience. Its state-of-the-art honeycomb inlet grille design not only optimizes airflow into the cooling tower but also serves as an effective barrier against impurities. This innovative feature significantly minimizes water splash, thereby reducing the risk of icing and water damage while preventing unnecessary water loss.

Efficient Air Inlet Louver Designed for Wet and Dry Air Contact

Features

Product Highlights

· Effectively prevents debris from penetrating, ensuring a clean and uncontaminated air environment.
· Efficiently prevents water droplet splashes, keeping interiors dry and protected.
· Limits sunlight entry into cooling towers to curb algae growth, promoting a healthier ecosystem.
· Significantly reduces noise emanating from the tower for a quieter operational environment.
· Delivers exceptional performance with minimal pressure drop, enhancing operational efficiency.
· Designed for easy installation, with straightforward access for routine cleaning and maintenance.
· Versatile usage across a vast array of new and retrofit applications, including air inlets for both package.
and field-erected counter flow and straight-sided cross flow towers, fresh air make-up systems, and air pollution control scrubbers.


Parameter

Properties
Whether you're customizing the NAL Air Inlet Louver by adjusting its length, width, materials, or thickness, Newin (Guangdong) Machinery Co., Ltd. stands by to fulfill your specific needs. Share your detailed requirements to receive a tailored solution and offer. We promise to address every customer demand. Additionally, our fill media is crafted with options for flame retardant or anti-bacterial finishes, made available upon request.

Module Length (Max)  mm 2440
Module Width (Max)  mm 600
Module Thickness  mm 65
Flute Height  mm 25
Sheet Thickness - Before Forming  mm 0.45
Sheet Thickness - After  Forming  mm 0.35
Max. application temp. (short time) - PVC  °C 60
Customized size and thickness available for special request. Contact Newin for details.


Structure & Installation Drawing
Newin provides comprehensive structure and installation drawing guidance, coupled with valuable onsite storage tips and a meticulous quality control report to ensure seamless integration upon delivery. When your materials arrive, rest assured, as our OEM capabilities or custom mold designs are at your disposal for any special requests.Efficient Air Inlet Louver Designed for Wet and Dry Air Contact

Application

Application & Usage

Designed to perfection, the Newin EVL air inlet louver is expertly crafted for use in counter flow cooling towers. With rigorous SGS testing aligned with ASTM Standards, it ensures unparalleled quality in infill, achieving optimal efficiency for your cooling towers. Simply provide us with the tower model or dimensions, and we will expertly determine the precise air inlet louver size for your replacement needs.
Efficient Air Inlet Louver Designed for Wet and Dry Air Contact


Applicable Commercial Standards
The sheets material is meticulously tested following stringent SGS protocols under ASTM standards. You can request testing for each property or the comprehensive suite of properties as evaluated by your products, ensuring quality assurance and adherence to the highest standards.

Property Test Method Values
Specific Gravity ASTM D792-13
Method B
1.426g/cm3
Oxygen Index ASTM D2863-13 34.50%
Tear Strength ASTM D1004-13 X direction 111 N
Y direction 121 N
Tensible Test ASTM D 882-12 Tensile Strength X direction 51.1 MPa
Y direction 45.3 Mpa
Elongation at
Break
X direction 87%
Y direction 56%
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin
Statements and methods presented are based upon the best available information and practices 
known to Newin. Conditions of use may vary and are beyond control, the user should undertake 
sufficient tests to determine the suitability for any intended use of the material.



Filed Data for Air Inlet Louver Replacement
Kindly provide the measurements below for your maintenance or repair projects. Trust in Newin for quality and reliability, whether it's a site visit or maintenance service. Our solutions are engineered precisely to fit the cooling tower fills or components, ensuring seamless integration and superior performance. Efficient Air Inlet Louver Designed for Wet and Dry Air Contact

NEWIN Manufacturing Base

Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
NEWIN FACTORY
Embark on an inspiring journey to our state-of-the-art manufacturing base, strategically nestled in the thriving industrial hub of Huizhou, Guangdong. Sprawling across an expansive 10,000 square meters, this facility stands as a beacon of innovation, excellence, and technological advancements.

ISO CERTIFICATION
We proudly underscore our unwavering commitment to unparalleled quality and environmental stewardship with our prestigious ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification, setting the benchmark for excellence.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience unrivaled efficiency and innovation with our Closed Type Cooling Tower Series, meticulously designed to deliver superior performance and unmatched reliability. Each model embodies the cutting-edge of cooling tower technology.
· NSH/ NST Discover the steadfast reliability of our Open Type Cooling Tower Series, expertly engineered for optimal operation and robust performance, setting industry standards and exceeding expectations for enduring excellence.
· NTG Explore the remarkable capabilities of our Industrial Type Cooling Tower Series, specifically crafted to conquer heavy-duty and demanding applications, ensuring resilience and power at every turn.
· NECN/NECH Seamlessly integrate cutting-edge efficiency with our state-of-the-art Evaporative Condenser models, setting new standards in performance and operational excellence, revolutionizing the cooling industry.
· NWFL Harness the transformative power of advanced technology with our Dry Air Cooler, expertly designed for superior airflow and maximum efficiency, optimizing every facet of cooling for unmatched results.

Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
NEWIN is your trusted partner in premier cooling tower solutions, offering an extensive range of accessories to meet your maintenance and replacement needs. Tailor your selection to fit a wide variety of cooling tower sizes and types. Contact us to customize the perfect suite of accessories tailored to your cooling tower for optimal performance.

CONTAIN:
· A robust Fan drive system, incorporating fan, fan stack, reducer, motor, and shaft, engineered for durability and precision, ensuring seamless operation.
· Highly efficient Water distribution components, featuring precision-engineered nozzles and advanced drift eliminators for superior performance, optimizing water management.
· Premium Heat exchange options, complete with top-quality PVC infills and cooling coils, crafted for optimal performance and energy efficiency, enhancing thermal regulation.
· Additional essential accessories, such as air inlet louvers and valves, to seamlessly complete your system, enhancing overall functionality and efficiency, and elevating performance.
Packaging & Shipping

Open type cooling towers shipment: Experience unparalleled security and precision as we masterfully orchestrate the transportation of your open-type cooling towers. Each tower is carefully cradled in premium-grade materials, utilizing cutting-edge packing techniques to ensure their immaculate arrival. Our steadfast commitment to protecting your investment provides an unmatched safeguard against any potential transit risks. Relish the ease of our streamlined logistics and prompt delivery, meticulously crafted to activate your cooling solutions without any delay.

Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
Closed type cooling towers shipment: Delight in the confidence provided by our outstanding packaging solutions, meticulously crafted for closed-type cooling towers. Each unit is enveloped with exquisite care and robust resilience, ready to withstand the most demanding transit conditions, ensuring their immaculate arrival and immediate deployment. Our unwavering dedication to excellence and swift delivery enables seamless integration of our state-of-the-art cooling innovations into your operations, liberating you from logistical concerns.
Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
Technical Strength& Standards

Efficient Air Inlet Louver Designed for Wet and Dry Air Contact
Efficient Air Inlet Louver Designed for Wet and Dry Air Contact

Certifications

Efficient Air Inlet Louver Designed for Wet and Dry Air ContactEfficient Air Inlet Louver Designed for Wet and Dry Air ContactEfficient Air Inlet Louver Designed for Wet and Dry Air ContactEfficient Air Inlet Louver Designed for Wet and Dry Air Contact

Efficient Air Inlet Louver Designed for Wet and Dry Air Contact














Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More