Newin Advanced Dry Air Cooling System for High-Capacity Needs

Product Details
Customization: Available
Ventilation Mode: Mechanical Ventilation
Material: Metal

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Newin Advanced Dry Air Cooling System for High-Capacity Needs
  • Newin Advanced Dry Air Cooling System for High-Capacity Needs
  • Newin Advanced Dry Air Cooling System for High-Capacity Needs
  • Newin Advanced Dry Air Cooling System for High-Capacity Needs
  • Newin Advanced Dry Air Cooling System for High-Capacity Needs
  • Newin Advanced Dry Air Cooling System for High-Capacity Needs
Find Similar Products
  • Overview
  • Features
  • Working Principle
  • Parameter
  • Components& Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWFL-V
Air Contact Form
Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
ISO, CE
Condition
New
Cooling Capacity
207~936kw
Transport Package
20/40/40hq Container
Specification
Multi-cells is available
Trademark
NEWIN
Origin
China
HS Code
84195000

Product Description

NEWIN High-Capacity Dry Air Cooler: Elevate Your Cooling Experience with Cutting-Edge Innovation.


NWFL-V The NWFL-V series represents the zenith of cooling technology, featuring a sophisticated V type dry air cooler superbly crafted with an advanced Free Cooling System. Revel in unparalleled cooling efficiency, making it the perfect choice for HVAC systems and various other state-of-the-art facilities. Indulge in exceptional cooling prowess while being eco-conscious, as this groundbreaking technology dramatically reduces water usage, setting it apart from conventional evaporative cooling techniques. Experience a new era of resource-efficient cooling with the NWFL-V series.
Newin Advanced Dry Air Cooling System for High-Capacity Needs
Features
· Ingeniously crafted V-type design coupled with a cutting-edge Free Cooling System,
Delivering unparalleled cooling efficiency while masterfully eliminating the need for water consumption.

· Integrates highly efficient components, including the sophisticated EC motor,
Ensuring optimal system efficiency and offering remarkable energy savings.

· Thoughtfully designed with comprehensive redundancy,
Guaranteeing consistent performance by adeptly preventing any loss in thermal efficiency.

· Offers supreme reliability along with hassle-free maintenance for ultimate ease of use.
Newin Advanced Dry Air Cooling System for High-Capacity Needs
 
Working Principle

Newin Advanced Dry Air Cooling System for High-Capacity Needs
When the NWFL-V adiabatic cooler springs into action:
The cutting-edge EC fan system, a masterpiece of modern engineering, deftly draws in refreshingly cool, dry air, guiding it seamlessly into the tower via the brilliantly conceived V-shaped finned tube heat exchanger. This innovative V-shaped architecture significantly amplifies the cooling prowess by expanding the contact surface area, thus magnifying the cooling effect on both the incoming air and the heated process fluid. This results in a substantial leap in heat exchange efficiency. Upon achieving optimal heat exchange with the cool, dry air through the partition wall, the hot saturated air is masterfully expelled from the tower, achieving unparalleled Free Cooling through an entirely non-evaporative process.

Series Type Capacity 1. Fan Drive System 2. Heat Exchange System
NWFL-V V Range EC axial fans Finned coil
Maximum thermal performance 207~936kw Intelligent frequency conversion, 
more energy saving
Maximum heat transfer surface
Free cooling 
system
Non-evaporative cooling, non-water consumption; Dry air cooler can replace chillers in winter, greatly reduce energy consumption.
Application Small to medium industries & HVAC;
The places with limited water consumption;
High temperature industrial cooling process etc.
Parameter
 
Newin Advanced Dry Air Cooling System for High-Capacity Needs
Model Cooling Capacity Total Dimension Fan Weight
L W H Nos of Fans Noise Level Power Shipping Operation
kw mm mm mm Nos dB(A) kw kg kg
NWFL-231-4D10-800V 200 2740 2050 2190 4 79.4 3.14  1187  1386 
NWFL-231-6D10-800V 250 2740 2050 2190 4 82.7 3.76  1332  1586 
NWFL-231-8D10-800V 290 2740 2050 2190 4 87.8 4.89  1477  1786 
NWFL-241-4D10-800V 255 2740 2050 2550 4 80 4.43  1329  1590 
NWFL-241-6D10-800V 315 2740 2050 2550 4 81.8 5.47  1522  1854 
NWFL-241-8D10-800V 360 2740 2050 2550 4 84.5 6.49  1714  2119 
NWFL-251-4D10-800V 310 2740 2050 2980 4 81.5 6.44  1493  1817 
NWFL-251-6D10-800V 400 2740 2050 2980 4 83 7.61  1732  2146 
NWFL-251-8D10-800V 450 2740 2050 2980 4 85 8.81  1971  2475 
NWFL-261-4D10-900V 375 2740 2250 3300 4 80.8 7.37  1675  2060 
NWFL-261-6D10-900V 470 2740 2250 3300 4 84.9 8.35  1961  2453 
NWFL-261-8D10-900V 535 2740 2250 3300 4 86.4 9.75  2247  2847 
Note:
1. Standard design working condition- Fluid in/out Temp. Difference: 5ºC.
2. Standard design ambient temperature- Temp. Approach: 15ºC.
3. Thermal design based on pure water.
4. Please contact NEWIN sales representative if the working condition is different from the above standard design condition.
Components& Options
Newin Advanced Dry Air Cooling System for High-Capacity Needs
· Heavy-duty Construction

Crafted with meticulous precision, our galvanized steel panels are fortified with the revolutionary NEWIN Armour anti-corrosion coating. This state-of-the-art protective layer provides unparalleled resistance, comparable to stainless steel, allowing for operation at higher concentration cycles. This innovative feature not only extends the equipment's operational life but also dramatically reduces water usage. Furthermore, in the event of minor damage, the coating can be easily repaired, ensuring lasting durability and dependability.
· V Type Finned Coil Heat Exchanger

Engineered to perfection, our finned coil heat exchanger features copper tubes expertly integrated with strategically spaced aluminum fins, achieving maximum heat exchange efficiency. The copper tubes are precisely brazed to the coil headers and expertly flared to the finned coil, ensuring superior thermal conduction and optimal performance.
Newin Advanced Dry Air Cooling System for High-Capacity Needs
Newin Advanced Dry Air Cooling System for High-Capacity Needs
· EC Axial Fan

- Our EC motor's straight-shaft drive, crafted with unmatched precision, boasts an impressive IP55 protection grade and F insulation grade, engineered for superior performance. It ensures uninterrupted, efficient operation in challenging hot and humid conditions while delivering energy efficiency that meets or exceeds IE4 standards.

- Equipped with robust tapered roller bearings, our fans exhibit remarkable load-bearing capacity and provide an exceptional service life of over 20,000 hours, guaranteeing consistent performance and durability throughout the years.

- Through rigorous static and dynamic testing, we've meticulously minimized noise while maintaining outstanding heat exchange efficiency. By harnessing PFC technology, harmonics are kept below 35%, ensuring that our EC fan system maintains high static efficiency even at reduced speeds, offering a perfect balance of power and serenity.
· Adiabatic Intelligent Controls

- Our EC fans incorporate intelligent frequency conversion, adapting seamlessly to diverse operational requirements and significantly optimizing energy savings.

- The system facilitates dry operation capabilities for instances where water usage is limited, ensuring unwavering reliability across various conditions.
Newin Advanced Dry Air Cooling System for High-Capacity Needs

 

· Options

- Enhance the coil's resistance to external elements, significantly boosting its longevity and durability.
- Implement a coil freeze-up safeguard to maintain operational integrity even in colder climates.
- Choose our low-noise upgrade to enjoy quieter operation without sacrificing performance.
- Increase redundancy for heightened reliability and added assurance in operation.
NEWIN Manufacturing Base

Newin Advanced Dry Air Cooling System for High-Capacity Needs
NEWIN FACTORY
Nestled within the vibrant heart of Huizhou, Guangdong, our expansive manufacturing base stretches across an impressive 10,000 square meters. This state-of-the-art facility is a cornerstone of innovation and a beacon of production excellence, setting the stage for groundbreaking achievements.

ISO CERTIFICATION
Newin proudly holds prestigious ISO certifications, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management. This underscores our unwavering commitment to superior quality and sustainable, eco-friendly practices.

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Newin Advanced Dry Air Cooling System for High-Capacity Needs
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Our cutting-edge Closed Type Cooling Tower Series is meticulously engineered to deliver optimal performance, ensuring reliability and efficiency in every operation.
· NSH/ NST Our highly efficient Open Type Cooling Tower Series is masterfully designed for diversified applications, offering flexibility and exceptional performance.
· NTG Our robust Industrial Type Cooling Tower Series is specifically tailored to meet the demands of challenging environments, providing unparalleled durability and efficiency.
· NECN/NECH Our sophisticated Evaporative Condenser systems are crafted to deliver superior cooling efficiency, setting new standards in the industry.
· NWFL Our innovative Dry Air Cooler solutions offer high-capacity, energy-efficient performance, redefining cooling technology with their advanced design.

Newin Advanced Dry Air Cooling System for High-Capacity Needs
NEWIN offers a comprehensive inventory of premium cooling tower accessories, meticulously crafted to cater to maintenance and replacement demands across a variety of cooling tower sizes and types. Reach out to us to customize the precise cooling tower accessories that meet your specific needs.

CONTAIN:
· Our fan drive system components, including fan, fan stack, reducer, motor, and shaft, are expertly crafted to enhance functionality and ensure seamless operation.
· Our water distribution elements, such as nozzles and drift eliminators, are designed for optimal fluid management, ensuring efficiency and reliability.
· Our heat exchange components, including PVC infills and cooling coils, guarantee efficient thermal transfer and robust performance.
· Our additional accessories, including air inlet louvers and valves, are meticulously engineered for seamless integration and superior functionality.
 
Packaging & Shipping

Open Type Cooling Towers Shipment: Embark on a worry-free journey with our meticulously planned shipping solutions, ensuring your advanced equipment reaches you punctually and in perfect condition. Rely on our seasoned logistics team to manage every intricate detail seamlessly, allowing you to concentrate on your core business priorities.

Newin Advanced Dry Air Cooling System for High-Capacity Needs
Closed Type Cooling Towers Shipment: Enjoy unmatched peace of mind with our secure and timely delivery of Closed Type Cooling Towers. Our thorough handling protocols are tailored to protect your valuable assets, guaranteeing they arrive at their destination intact. Rest assured, our precise shipping strategies safeguard your investments every step of the way.
Newin Advanced Dry Air Cooling System for High-Capacity Needs
Newin Advanced Dry Air Cooling System for High-Capacity Needs
Technical Strength& Standards

Newin Advanced Dry Air Cooling System for High-Capacity Needs
Newin Advanced Dry Air Cooling System for High-Capacity Needs

Certifications

Newin Advanced Dry Air Cooling System for High-Capacity NeedsNewin Advanced Dry Air Cooling System for High-Capacity NeedsNewin Advanced Dry Air Cooling System for High-Capacity NeedsNewin Advanced Dry Air Cooling System for High-Capacity Needs

Newin Advanced Dry Air Cooling System for High-Capacity Needs

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More