Presenting the NEWIN NVD Series: an unparalleled Cellular Cooling Tower PVC Drift Eliminator designed to excel in performance and reliability. Engineered with precision, this cutting-edge solution effectively minimizes water loss, ensuring optimal efficiency for both wet and dry cooling applications. Discover the perfect synergy of advanced technology and superior quality with the NEWIN NVD Series, setting a new standard in drift elimination within cooling systems.
Product Description
NVD Newin NVD series cellular drift eliminator is your ultimate solution for maintaining the efficiency and safety of cooling towers. It expertly removes small water droplets entrained in the exhaust air, addressing potential nuisances and health risks by preventing their escape with heated air. Our innovative NVD series drift eliminators are crafted to compel air streams through a complex, winding path. As water droplets traverse this path, they are skillfully redirected, striking the side walls of the drift eliminator. This process facilitates coalescence and guides the water back into the cooling tower's wet section, ensuring superior performance and sustainability.
FEATURES
- Anti-aging properties coupled with exceptional water absorption capabilities.
- Minimal airflow resistance combined with robust, high-strength construction.
- Effortless installation process and an impressive long service life, promising reliability and durability.
Parameter
PROPERTIES
Our NVD drift eliminators are engineered to cater to a diverse array of specifications, including variations in length, width, materials, and thickness. We invite you to share your detailed requirements to ensure you receive the perfect solution and offer tailored to your needs. At Newin, we pride ourselves on meeting all customer demands with precision. Additionally, we offer fill media options with flame retardant or anti-bacterial properties upon request, providing you with solutions that prioritize safety and hygiene.
Module Length (Max) |
mm |
2440 |
Module Width (Max) |
mm |
500 |
Module Height |
mm |
130 |
Flute Height |
mm |
25 |
Sheet Thickness - Before Forming |
mm |
0.45 |
Sheet Thickness - After Forming |
mm |
0.38 |
Max. application temp. (short time) - PVC |
°C |
60 |
Customized size and thickness available for special request. Contact Newin for details. |
STRUCTURE & INSTALLATION DRAWING
Newin provides comprehensive structure and installation drawing advice, ensuring that our customers receive unparalleled guidance. Alongside your shipment, you will receive jobsite storage advice and a meticulous quality control report, ensuring everything is perfect upon receipt. For those with unique needs, OEM solutions or special mold designs are available upon request, guaranteeing a product that aligns perfectly with your specific requirements.
Application
APPLICATION & USAGE
The Newin NVD Cellular Drift Eliminator is expertly designed for optimum performance in counter-flow cooling towers. Its application promises superior quality and efficiency, ensuring your cooling system operates at its best. Our drift eliminator has undergone rigorous SGS testing adhering to ASTM Standards, ensuring high-quality infill that maximizes the efficiency of your cooling tower. Provide us with your tower model or dimensions, and we will expertly assess the number of sheets required for your cooling tower replacement.
Applicable Commercial Standards
The materials used for our sheets are meticulously tested to meet the stringent requirements of SGS with adherence to ASTM standards. On request, each or all properties demonstrated by your products can be thoroughly tested to ensure uncompromising quality.
Property |
Test Method |
Values |
Specific Gravity |
ASTM D792-13
Method B |
1.426g/cm3 |
Oxygen Index |
ASTM D2863-13 |
34.50% |
Tear Strength |
ASTM D1004-13 |
X direction |
111 N |
Y direction |
121 N |
Tensible Test |
ASTM D 882-12 |
Tensile Strength |
X direction |
51.1 MPa |
Y direction |
45.3 Mpa |
Elongation at
Break |
X direction |
87% |
Y direction |
56% |
Values shown above based on SGS Test No.: GZIN1708039662PS by Newin |
Statements and methods presented are based upon the best available information and practices known to Newin. Conditions of use may vary and are beyond control, the user should undertake sufficient tests to determine the suitability for any intended use of the material. |
FILED DATA FOR CELLUAR DRIFT ELIMINATOR REPLACEMENT
Complete the measurement data below for maintenance or repair projects. Trust in Newin for quality and reliability, whether you require a site visit or maintenance service. Our solutions are engineered to perfectly match your cooling tower fills or components, ensuring seamless integration and performance.
NEWIN Manufacturing Base

Explore the Impressive NEWIN FACTORY
Strategically nestled in the thriving heart of Huizhou, Guangdong, our expansive manufacturing base stretches over a remarkable 10,000 square meters, serving as a powerhouse of innovation.
ISO CERTIFICATION - A Resounding Mark of Quality
Proudly adorned with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification, our unwavering dedication to unrivaled quality and sustainable practices shines brightly.
WORKSHOPS - Centers of Excellence and Innovation
State-of-the-art Welding Workshop: Witness the mastery of precision and innovation, where every weld is a testament to superior craftsmanship.
Advanced Filler Thermoforming Workshop: Where the finest cutting-edge techniques converge with unmatched craftsmanship, producing exceptional results that set industry standards.
Precision Sheet Metal Processing Workshop: Perfecting the art of metalwork with an unwavering commitment to unmatched accuracy and finesse.
Cooling Tower Assembly Workshop: Excellence meticulously assembled, piece by piece, ensuring superior performance and reliability for every application.
TESTING - Unparalleled Quality Assurance
Independent Testing LAB: Ensuring product reliability and exceptional performance through rigorous testing protocols that exceed industry benchmarks.

NEWIN COOLING TOWERS: Efficiency Masterfully Redefined
· NWN/ NWF/ NCFN: Experience our Cutting-edge Closed Type Cooling Tower Series. Cutting-edge Closed Type Cooling Tower Series: Meticulously engineered for optimal efficiency and unmatched reliability across diverse applications.
· NSH/ NST: Discover our Innovative Open Type Cooling Tower Series. Innovative Open Type Cooling Tower Series: Seamlessly merging exquisite design with functionality for superior cooling performance.
· NTG: Unveil our Robust Industrial Type Cooling Tower Series. Robust Industrial Type Cooling Tower Series: Engineered to excel and endure within even the most demanding environments, ensuring longevity and reliability.
· NECN/NECH: Explore our Efficient Evaporative Condenser. Efficient Evaporative Condenser: Precision-engineered to deliver maximum cooling efficiency and outstanding performance.
· NWFL: Discover our High-performance Dry Air Cooler. High-performance Dry Air Cooler: Offering unparalleled cooling power blended seamlessly with an energy-saving design for optimal operational efficiency.

NEWIN stands as your trusted partner, offering a comprehensive range of essential cooling tower accessories. We meticulously cater to the maintenance and replacement needs of every cooling tower, regardless of its size or type. Reach out to us for bespoke solutions tailored precisely to your specific accessory requirements.
CONTAIN: Comprehensive Cooling Solutions for Every Need
· Comprehensive Fan drive system: Comprising fan, fan stack, reducer, motor, shaft, etc., each component meticulously engineered for pinnacle performance.
· Efficient Water distribution components: Including nozzles, drift eliminator, etc., expertly designed to guarantee superior water management.
· Superior Heat exchange elements: Featuring high-quality PVC infills and cooling coil, these components enhance thermal efficiency with effortless grace.
· Diverse Other accessories: Including air inlet louver and valve, enhancing the overall functionality and superior efficiency of your cooling tower.
Packaging & Shipping
Open type cooling towers shipment: Elevate your expectations with our expertly crafted shipping solutions tailored for open-type cooling towers. Revel in the unmatched reliability and punctuality of our service, as we diligently ensure your critical industrial cooling components are delivered with precision and care. Trust us to provide the reassurance you need for your operational victories, establishing a robust foundation for your enduring success.

Closed type cooling towers shipment: Maximize your industrial cooling capabilities with our flawlessly organized logistics for closed-type cooling towers. We promise a delivery process that is not only safe and swift but also secure and efficient, greatly minimizing downtime while boosting operational consistency. With our unwavering commitment to excellence, focus entirely on achieving outstanding business performance and catalyzing impressive growth.

Technical Strength& Standards


Certifications