Customization: | Available |
---|---|
Warranty: | 2 Years |
Cooling Method: | Cross Flow |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
· Counter flow heat transfer, Higher condensation efficiency
Efficient condensation performance specially in hot and humid conditions.
· Closed circuit system, Energy saving and Environmental protection
Keep media clean, reduce water consumption and maintenance cost, longer equipment service life.
· Compact structure design, High Strength and Convenient
Small occupation area, Convenient to the shipment, Ease of installation and maintenance.
When NECN evaporative condenser is in operation:
The condensing coil is the main channel of refrigerant steam, which condenses the refrigerant steam into liquid by the way of evaporating and absorbing heat by spraying water. At the same time, the axial flow fan provides forced convection, which causes the air to form a counter flow inside the condenser and exchange heat with the refrigerant steam, so that to achieve efficient condensation performance.
Series | Type | Capacity | Fan Drive System | Condensation |
NECN | Counter Flow | Range | Axial fans | Condensing coil |
Fuller heat exchange | 40~4000kw | Provides forced convection, which causes the air to form a counter flow inside the condenser | The main channel of refrigerant steam. | |
Counter flow heat exchange, Closed circuit system | High efficiency, Energy-saving and Environmental protection | |||
Application | Refrigeration, Air conditioning, Chemical industry, Medicine and other fields. |
Table 1. Technical Specification
Item | Heat Rejection Capacity (KW) |
Dimension (mm) |
Axial Fan | Spray Pump | NH3 Ammonia Charge (kg) |
Weight (kg) |
|||||
Model | Length | Width | Height | Air Volume (m³/h) |
Power (Kw)x Qty |
Flow (m³/h) |
Power (Kw) |
Dry | Wet | ||
NECN-40 | 40 | 1150 | 900 | 1920 | 10500 | 0.55 | 14 | 0.75 | 8 | 350 | 600 |
NECN-64 | 64 | 1150 | 1150 | 1920 | 13050 | 0.75 | 14 | 0.75 | 9 | 400 | 700 |
NECN-80 | 80 | 2000 | 1150 | 2200 | 26100 | 0.75*2 | 30 | 1.1 | 11 | 520 | 1000 |
NECN-120 | 120 | 2000 | 1150 | 2200 | 26100 | 0.75*2 | 30 | 1.1 | 13 | 570 | 1100 |
NECN-160 | 160 | 2500 | 1150 | 2200 | 36600 | 1.1*2 | 40 | 1.5 | 18 | 650 | 1600 |
NECN-200 | 200 | 2500 | 1150 | 2350 | 36600 | 1.1*2 | 40 | 1.5 | 28 | 750 | 1700 |
NECN-280 | 280 | 2500 | 1400 | 2650 | 40600 | 1.5*2 | 40 | 1.5 | 41 | 850 | 1800 |
NECN-320 | 320 | 2500 | 1400 | 2650 | 40600 | 1.5*2 | 60 | 1.5 | 43 | 1050 | 2000 |
NECN-400 | 400 | 2500 | 1400 | 2650 | 46900 | 2.2*2 | 60 | 1.5 | 45 | 1250 | 2300 |
NECN-480 | 480 | 2500 | 1400 | 2650 | 53000 | 2.6*2 | 60 | 1.5 | 65 | 1350 | 2400 |
NECN-560 | 560 | 3000 | 1400 | 2850 | 63800 | 3.5*2 | 65 | 2.2 | 65 | 1650 | 3000 |
NECN-640 | 640 | 3000 | 1400 | 2850 | 90000 | 4*2 | 65 | 2.2 | 81 | 1850 | 3300 |
NECN-800 | 800 | 3000 | 2180 | 2850 | 90000 | 4*2 | 110 | 3 | 83 | 2050 | 3800 |
NECN-1000 | 1000 | 3518 | 2180 | 3250 | 110000 | 5.5*2 | 110 | 3 | 109 | 2450 | 4300 |
NECN-1200 | 1200 | 3518 | 2180 | 2850 | 150000 | 7.5*2 | 110 | 3 | 120 | 3150 | 4300 |
NECN-1400 | 1400 | 4010 | 2980 | 3910 | 180000 | 7.5*2 | 170 | 5.5 | 142 | 3700 | 7100 |
NECN-1600 | 1600 | 4010 | 2980 | 3910 | 220000 | 7.5*2 | 170 | 5.5 | 166 | 4180 | 7600 |
NECN-2000 | 2000 | 4510 | 2980 | 3910 | 300000 | 11*2 | 170 | 5.5 | 220 | 5050 | 8900 |
NECN-2400 | 2400 | 7036 | 2180 | 2850 | 300000 | 7.5*4 | 220 | 3*2 | 237 | 6300 | 8600 |
NECN-2800 | 2800 | 8020 | 2980 | 3910 | 360000 | 7.5*4 | 340 | 5.5*2 | 283 | 7400 | 14200 |
NECN-3200 | 3200 | 8020 | 2980 | 3910 | 440000 | 7.5*4 | 340 | 5.5*2 | 330 | 8360 | 15200 |
NECN-4000 | 4000 | 8020 | 2980 | 3910 | 600000 | 11*4 | 340 | 5.5*2 | 438 | 10100 | 17800 |
Table 2. Heat Emission Correction Index for R717
Condensing Temp. (°C) |
Air Inlet Wet Bulb Temp. (°C) | ||||||||||||
18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | |
30 | 1.40 | 1.51 | 1.63 | 1.79 | 1.99 | 2.24 | 2.56 | 3.00 | |||||
32 | 1.18 | 1.25 | 1.32 | 1.43 | 1.55 | 1.70 | 1.88 | 2.11 | |||||
34 | 1.02 | 1.07 | 1.12 | 1.19 | 1.28 | 1.36 | 1.48 | 1.61 | 1.80 | 2.06 | |||
35 | 0.95 | 0.99 | 1.03 | 1.08 | 1.15 | 1.23 | 1.30 | 1.39 | 1.53 | 1.69 | 1.90 | 2.15 | 2.47 |
36 | 0.89 | 0.92 | 0.96 | 1.01 | 1.07 | 1.13 | 1.20 | 1.28 | 1.39 | 1.53 | 1.70 | 1.91 | 2.17 |
38 | 0.78 | 0.81 | 0.83 | 0.86 | 0.90 | 0.94 | 0.99 | 1.05 | 1.12 | 1.21 | 1.31 | 1.44 | 1.59 |
40 | 0.70 | 0.72 | 0.74 | 0.76 | 0.80 | 0.83 | 0.87 | 0.91 | 0.96 | 1.02 | 1.09 | 1.18 | 1.29 |
42 | 0.63 | 0.64 | 0.66 | 0.68 | 0.71 | 0.74 | 0.76 | 0.80 | 0.84 | 0.88 | 0.93 | 0.99 | 1.06 |
44 | 0.56 | 0.58 | 0.59 | 0.61 | 0.63 | 0.65 | 0.67 | 0.70 | 0.76 | 0.76 | 0.79 | 0.83 | 0.86 |
Table 3. Heat Emission Correction Index for R22 & R134a
Condensing Temp. (°C) |
Air Inlet Wet Bulb Temp. (°C) | |||||||||||||
10 | 12 | 14 | 16 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 28 | |
29 | 0.86 | 0.94 | 1.03 | 1.15 | 1.37 | 1.43 | 1.55 | 1.68 | 1.92 | 2.10 | 2.52 | 3.10 | ||
31 | 0.77 | 0.83 | 0.90 | 0.99 | 1.10 | 1.17 | 1.24 | 1.34 | 1.47 | 1.62 | 1.83 | 2.10 | 2.48 | |
33 | 0.69 | 0.73 | 0.79 | 0.86 | 0.94 | 1.00 | 1.02 | 1.10 | 1.20 | 1.28 | 1.40 | 1.56 | 1.75 | 2.38 |
35 | 0.62 | 0.66 | 0.70 | 0.76 | 0.83 | 0.86 | 0.90 | 0.93 | 1.00 | 1.07 | 1.18 | 1.25 | 1.38 | 1.68 |
37 | 0.57 | 0.60 | 0.63 | 0.67 | 0.72 | 0.76 | 0.78 | 0.82 | 0.85 | 0.90 | 0.96 | 1.02 | 1.10 | 1.30 |
39 | 0.55 | 0.57 | 0.59 | 0.62 | 0.65 | 0.68 | 0.70 | 0.72 | 0.75 | 0.79 | 0.84 | 0.88 | 0.95 | 1.10 |
41 | 0.48 | 0.49 | 0.52 | 0.54 | 0.57 | 0.59 | 0.61 | 0.63 | 0.66 | 0.68 | 0.71 | 0.75 | 0.78 | 0.90 |
43 | 0.44 | 0.46 | 0.48 | 0.50 | 0.52 | 0.54 | 0.55 | 0.57 | 0.59 | 0.61 | 0.63 | 0.66 | 0.68 | 0.75 |
45 | 0.41 | 0.42 | 0.44 | 0.46 | 0.48 | 0.49 | 0.50 | 0.52 | 0.53 | 0.55 | 0.56 | 0.58 | 0.61 | 0.66 |
Instructions for Selection
1. Confirm condensing temperature, wet bulb temperature.
2. Calculate total heat abstraction amount that goes through system to condensers.
3. Take a reference to below Table 2. or Table 3., select heat abstraction amount correction index.
4. Total amount of heat abstraction multiplies heat correction index equals to the condensing load during the working conditions.
5. Take a reference to Graph Specification sheet, select the heat abstraction amount data which is bigger or equivalent tothe data after correction.
Axial Flow Fan
Adopts cooling tower special aluminum alloy axial flow fan,forward type blade structure design, small wind resistance, big air volume, low noise, good performance, high efficiency. Streamline high strength fan stack ensures airflow uniform through the fan inlet and outlet area, maximum reduce the energy consumption. Fan motor's protection class: IP55, Insulation class: F class.
Drift Eliminator
Adopts NEWIN made EVD series drift eliminator, advanced self-extinguishing PVC material. Special flow flute design changes the air flow direction, small wind resistant and effectively remove from the wet air moisture in the air, reduced the drift loss below 0.001%, maximum save the water, what's more, to make sure the area around cooling tower no pollution, and prevent from the germs spreading.
Water Distribution System
Spray system adopts SPJT pressure type nozzles, provide a fine and dense liquid mist under the pressure action of water pump, large spray area and evenly distribution.
Condensing Coil
Adopts 304 stainless steel coil, high anti-corrosion. Special coil set design, improving heat transfer performance. * Coil materials: SUS 304/316, Copper or Galvanized steel for option.
Air Inlet Grille
Easy disassembled type design. Special 3D stereo 45 degree ventilation channel, greatly improving product rigidity and wind load resistance. It reduces noise and prevents the growth of algae and it is anti-corrosion, anti-ultraviolet and maintenance free.
Heavy-duty Construction
Utilizing the NEWIN MAH series fill film, crafted from advanced self-extinguishing PVC material, this layer features a special texture design to offer ample heat exchange surface area. Equipped with a grille and water receiving edge to minimize drift water loss, it guarantees superior heat transfer efficiency. Optionally, upgrade to high-temperature resistant materials for enhanced performance.
About NWN-Armour plate
That is the galvanized steel panel with NWN-Armour anti-corrosion coating have excellent resistance and corrosion resistance approaching the characteristics of stainless steel. A cost-effective alternative to Stainless Steel 304.
NEWIN FACTORY
Nestled in the vibrant landscape of Huizhou, Guangdong, our expansive manufacturing base stretches across 10,000 square meters of cutting-edge facilities. This state-of-the-art environment is a cradle for creativity and production excellence, where innovation thrives.
ISO CERTIFICATION
Proudly flaunting esteemed ISO certifications, including ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, Newin exemplifies a steadfast dedication to peak quality and eco-friendly practices.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
Open Type Cooling Towers Shipment: Experience the pinnacle of logistics excellence with our expertly coordinated shipping solutions. We ensure that your equipment not only arrives on time but also in immaculate condition, ready to deliver peak performance right out of the box. Relish in the seamless transition from our facility to your site, where everything is meticulously planned and executed to perfection.