Introducing the NEWIN NWF Series: A Mixed Flow Closed Type Cooling Tower like no other, designed to transform industrial cooling solutions with unparalleled efficiency.
NWF The NWF series closed cooling tower integrates groundbreaking composite flow cooling technology, ensuring stable performance that is both energy-efficient and environmentally conscious. As the spray water cools the heat exchange coil, it journeys into the cold water basin via the PVC heat exchange layer, significantly reducing the tower's internal temperature while minimizing the noise traditionally associated with direct water fall.
High-Efficiency Mixed Flow Closed Circuit System
Operation
In this advanced cooling system, the fluid medium navigates through a high-performance serpentine coil heat exchanger. A continual external spray system moistens the coil's surface, promoting optimal cooling. This process allows the cooled medium to transfer heat efficiently with the spray water through a partition wall heat exchanger, ensuring a closed loop that maximizes cooling effectiveness. Cool, dry air enters the tower from the side, crossing paths with the spray water's vertical flow, creating a sophisticated composite heat transfer driven by fans. Post heat exchange, high-temperature saturated air is expelled from the tower, and the spray water undergoes a second heat transfer through the PVC heat exchange layer, before being collected in a basin, removing additional heat and ensuring exceptional cooling performance.
Advantage
> The Revolutionary mixed flow closed-loop circulation system ensures media purity, slashes maintenance costs, and preserves vital water resources, all while delivering superior cooling performance.
> This innovative engineering feat features a stainless steel coil heat exchanger and PVC heat exchange layer, a combination not only known for its efficiency but also its sleek appearance. This state-of-the-art design optimizes the heat transfer area, boosts heat exchange efficiency, and aids in minimizing noise pollution.
> The precisely engineered single-side air intake design reduces rear tower noise emissions, making it perfectly suited for noise-sensitive settings.
> The product boasts a smartly engineered compact structure and space-efficient design, facilitating the integration of multiple cooling towers seamlessly.
Features
COOLING TOWER PARTS
1. Axial Flow Fan
Introducing our high-performance aluminum alloy axial flow fan, engineered for superior operational efficiency with low noise output and stability. Its motor comes with an IP55 protection grade and F insulation grade, ensuring unmatched safety and steadfast dependability.
2. External Spray System
This innovative system sprays cool water onto the heat exchange coil, consistently maintaining a wet coil surface to optimize cooling efficiency.
3. Stainless Steel Heat Exchange Coil
Crafted from premium stainless steel, these coils deliver outstanding heat exchange efficiency and superior corrosion resistance. Their lightweight design extends the equipment's lifespan, and their recyclable nature underscores environmental sustainability.
4. MAH PVC Fill Film (PVC heat exchange layer)
Designed for excellence, the PVC filler heat exchange layer incorporates a seamless design that integrates filler, air inlet grille, and drift eliminator, ensuring steady air intake and drastically reducing water drift loss. This unique surface texture maximizes heat exchange surface area, boosting overall efficacy. Optionally, it can be upgraded to high-temperature materials to meet specific project conditions.
5. MBD PVC Drift Eliminator
Specifically tailored for closed cooling towers, this advanced drift eliminator efficiently extracts airborne water droplets with minimal wind resistance. It boasts a remarkable 99.99% capture rate, ensuring peak heat transfer performance.
6. Air Inlet Louver
Our air inlet louver guarantees that cool, dry air is evenly pulled through the coil and PVC heat exchange layer while limiting sun exposure and inhibiting microbial growth.
7. Heavy-duty Construction
Constructed with high-quality Z700 galvanized steel for robust durability and excellent corrosion resistance.For extreme environments, opt for the SUS314/316 or NWN-Armour anti-corrosion coated steel, offering extraordinary protection.
8. Access Door
Facilitates easy entry to the inner maintenance platform through the access door, simplifying maintenance tasks.
The presence of an Inspection Platform Inside the cooling tower is an inspection platform that significantly enhances the ease and convenience of performing routine inspections and maintenance, ensuring operational excellence.
Product Parameters

Design Conditions
NWF |
Dimension (mm) |
Weight (kg) |
Model |
L |
W |
H |
Dry |
Wet |
NWF-120-Z7-S |
2300 |
1910 |
2850 |
843 |
1935 |
NWF-180-Z7-S |
2300 |
1910 |
2930 |
883 |
2006 |
NWF-230-Z7-S |
2850 |
2110 |
2930 |
1140 |
2701 |
NWF-290-Z7-S |
3550 |
2110 |
2930 |
1377 |
3396 |
NWF-350-Z7-S |
4150 |
2110 |
2930 |
1601 |
4013 |
NWF-450-Z7-S |
4550 |
2250 |
3480 |
2055 |
4706 |
NWF-600-Z7-S |
4550 |
2250 |
3720 |
2197 |
4899 |
NWF-750-Z7-S |
5200 |
2250 |
4270 |
3201 |
6920 |
NWF-900-Z7-S |
5200 |
2250 |
4490 |
3549 |
7535 |
NWF-1000-Z7-S |
5200 |
2870 |
4490 |
4045 |
8589 |
NWF-1150-Z7-S |
5900 |
2870 |
4540 |
4536 |
9677 |
NWF-1450-Z7-S |
5900 |
3150 |
4690 |
5321 |
12230 |
NWF-1750-Z7-S |
6500 |
3150 |
4690 |
5943 |
13744 |
NWF-2300-Z7-S |
7500 |
3250 |
4900 |
6963 |
15214 |
Optional Various Additional Functions
Discover an array of optional enhanced functionalities designed to elevate the performance of your operations: Two-speed & VFD variable frequency motor, Vibration Cut-off Switch, Advanced Electronic Descaler, Comprehensive Water Treatment Equipment, Automatic Anti-freeze Heating System, Upgraded Noise Reduction, and an External Maintenance Platform with Guardrails. Additionally, enjoy seamless installation and maintenance with our specialized boom, engineered for efficiency.
Cost-effective Anti-Corrosion Solution
NWN-Armour Anti-corrosion Technology
Experience unparalleled protection with NWN-Armour anti-corrosion coating. Our products, coated with this innovative technology, show exemplary resistance to corrosion, closely rivaling the properties of stainless steel. This solution offers a remarkably cost-effective alternative to traditional stainless steel, maintaining superb durability and longevity for your equipment.el.
Our Wet Coil Cooling Tower with Enhanced Cooling Capacity is tailored to meet the diverse and demanding needs of numerous industries. Ideal for the energy sector, it efficiently manages thermal loads. In the pharmaceutical industry, it ensures precise temperature control. In HVAC systems, it enhances system performance and reliability. The chemical industry benefits from its robust cooling capabilities, while machinery manufacturing experiences increased operational efficiency. Perfect for metal processing, it provides consistent cooling for improved output. Plastic products manufacturing sees enhanced product quality, and industrial cooling applications enjoy reliable performance. Lastly, food processing operations benefit from its ability to maintain stringent hygiene standards and ideal environmental conditions.
NEWIN Manufacturing Base

State-of-the-Art NEWIN FACTORY
Nestled in Huizhou, Guangdong, our expansive manufacturing base spans a remarkable 10,000 square meters.
Industry-Leading ISO CERTIFICATION
Proudly certified with ISO9001:2015 for Quality Management and ISO14001:2015 for Environmental Management, assuring excellence.
Innovative WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
High-Tech Sheet Metal Processing Workshop
Efficient Cooling Tower Assembly Workshop
RIGOROUS TESTING
Our Independent Testing LAB ensures superior performance and reliability.
Explore the NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Discover the Closed Type Cooling Tower Series, engineered for utmost performance.
·
NSH/ NST Explore the Open Type Cooling Tower Series, designed for efficiency and durability.
·
NTG Experience the power of the Industrial Type Cooling Tower Series.
·
NECN/NECH Efficient and innovative Evaporative Condenser solutions.
·
NWFL Advanced Dry Air Cooler for optimal performance.
NEWIN offers a comprehensive range of cooling tower accessories, ensuring seamless maintenance and replacement for any size and type. Contact us to tailor the perfect set for your cooling tower.
OUR RANGE CONTAINS:
· Comprehensive Fan Drive System (fan/ fan stack/reducer/motor/shaft etc.)
· Precision Water Distribution components (nozzles/ drift eliminator etc.)
· Efficient Heat Exchange solutions (PVC infills/ cooling coil etc.)
· Additional accessories for enhanced functionality (air inlet louver/ valve etc.)
Packaging & Shipping
Open type cooling towers shipment
Closed type cooling towers shipment
Technical Strength& Standards


Certifications