Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency

Product Details
Customization: Available
Certification: ISO, CE
Condition: New
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
  • Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
  • Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
  • Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
  • Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Find Similar Products
  • Overview
  • Product Description
  • Parameter
  • Options
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
HOH
Ventilation Mode
Natural Ventilation
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Material
PVC/PP
Color
Black
Module Height
Customization
Module Width
810/910/1010mm
Flute Height
18mm
Service Life
More Than 20 Years
Installation
Hand up/Glued Into Blocks
Transport Package
Woodencase 20gp/40gp Container
Trademark
NEWIN
Origin
China
HS Code
8419909000
Production Capacity
1000000mt Per Year

Product Description

Discover the pinnacle of heat exchange efficiency with Newin's groundbreaking HOH Series Cooling Tower Fills. Designed with state-of-the-art innovation, this masterpiece is engineered to deliver unprecedented power and performance, guaranteeing optimal cooling for your operations. Place your confidence in Newin's expert craftsmanship, known for its unmatched reliability and exceptional heat exchange capabilities, and elevate your cooling solutions to new heights.
Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Product Description

HOH Discover the unparalleled performance of the Newin HOH Film Fill, a premium addition to your cooling tower system. This groundbreaking product is designed as a hanging film type cooling tower fill, skillfully incorporating a highly efficient cellular drift eliminator. Ingeniously molded with the air inlet louver, it evenly disperses water through a delicate thin film, gracefully flowing over expansive vertical surfaces. This process ensures maximum exposure to airflow, drastically enhancing cooling efficiency. Compared to traditional splash-type fills, this innovation offers significantly more water surface exposure per cubic foot, taking cooling performance to an entirely new level. Tested rigorously to ASTM Standards by SGS, this high-quality infill is engineered to boost your cooling tower's performance. Flexible installation options include hanging or glue assembly methods. Crafted from PVC with a commendable flame spread rating, it is designed to be self-extinguishing, ensuring safety and durability.


Pictures in Details

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Parameter
Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
 
 Module Length (Max)  mm Depend on customer demand
 Module Width   mm 810/910/1010
 Flute Height  mm 18
 Sheet Thickness - Before Forming  mm 0.32
 Sheet Thickness - After  Forming  mm 0.28
 Max. application temp. (short time) - PVC  °C 60
 Max.operating temp. (short time) - PP  °C 95
 Customized thickness available for special request. Contact Newin for details!
At Newin (Guangdong) Machinery Co., Ltd., we understand that customization is key when it comes to the HOH film fill requirements. Whether it's length, width, materials, or thickness, we are here to cater to your specific needs. Share your detailed requests with us to receive the perfect solution and personalized offer. Our comprehensive product range ensures that we can satisfy all customer demands, including options for flame retardant or anti-bacterial fill media available upon request.
 

Field Data for Cross Flow Film Fill Replacement
Please provide the measurements below for your cooling tower maintenance or repair projects. Trust in Newin for unparalleled quality and reliability. Whether you require a site visit or maintenance service, our solutions are meticulously engineered to seamlessly integrate with your cooling tower fills and components.

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Options

You may also be interested in exploring the following related products that perfectly complement our exceptional offerings and elevate your overall experience to new heights:

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
NEWIN Manufacturing Base

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
NEWIN FACTORY
Embark on a journey to our state-of-the-art manufacturing base, situated in the vibrant industrial hub of Huizhou, Guangdong. Our facility sprawls over an impressive 10,000 square meters, standing as a beacon of innovation and excellence.

ISO CERTIFICATION
Our unwavering commitment to unmatched quality and environmental responsibility is exemplified by our ISO certifications: the ISO9001:2015 Quality Management System Certification and the ISO14001:2015 Environmental Management System Certification.

WORKSHOPS
Cutting-edge Welding Workshop
Advanced Filler Thermoforming Workshop
Precision Sheet Metal Processing Workshop
Comprehensive Cooling Tower Assembly Workshop

TESTING
Dedicated Independent Testing LAB

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Experience exceptional efficiency with our Closed Type Cooling Tower Series, crafted for superior performance and unwavering reliability.
· NSH/ NST Discover unrivaled reliability with our Open Type Cooling Tower Series, engineered for premium operation and seamless integration.
· NTG Explore the robust power of our Industrial Type Cooling Tower Series, designed for heavy-duty applications and exceptional results.
· NECN/NECH Seamlessly integrate superior efficiency with our innovative Evaporative Condenser models, offering modern solutions for contemporary needs.
· NWFL Harness the power of advanced technology with our state-of-the-art Dry Air Cooler, designed for optimal airflow and peak performance.

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
NEWIN is your trusted partner in cooling tower solutions, offering a broad spectrum of accessories to meet your maintenance and replacement needs for various cooling tower sizes and types. Contact us to customize the ideal accessory suite for your cooling tower.

CONTAIN:
· A robust Fan drive system, including fan, fan stack, reducer, motor, and shaft, engineered for maximum efficiency and durability.
· Efficient Water distribution components, featuring advanced nozzles and drift eliminators designed for optimal water management.
· Premium Heat exchange options, with state-of-the-art PVC infills and cooling coils that ensure excellent heat transfer efficiency.
· Additional essential accessories, such as air inlet louvers and high-performance valves, to complete and enhance your system.
 
Packaging & Shipping

Open type cooling towers shipment: Our meticulously engineered open-type cooling towers are expertly packaged to ensure they reach you in pristine condition. We prioritize safety and security, using high-quality materials and strategic packing techniques to safeguard against any potential transit damages. Experience seamless logistics and punctual delivery, ensuring that your cooling solutions are operational without delay.

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Closed type cooling towers shipment: Experience unmatched peace of mind with our carefully crafted packaging solutions for closed-type cooling towers. Each unit is diligently encased to endure transportation challenges, ensuring they arrive at your location in perfect condition and ready to perform. With our unwavering commitment to quality assurance and prompt shipping, you can focus on harnessing the power of our advanced cooling technology for your needs.
Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Technical Strength& Standards

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency
Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency

Certifications

Efficient Cooling Tower Infill for Superior Natural Ventilation EfficiencyEfficient Cooling Tower Infill for Superior Natural Ventilation EfficiencyEfficient Cooling Tower Infill for Superior Natural Ventilation EfficiencyEfficient Cooling Tower Infill for Superior Natural Ventilation Efficiency

Efficient Cooling Tower Infill for Superior Natural Ventilation Efficiency

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier