Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower

Product Details
Customization: Available
After-sales Service: 12 Months
Warranty: 24 Months
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
  • Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
  • Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
  • Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
  • Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
  • Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
Find Similar Products
  • Overview
  • Features
  • Product Parameters
  • Application
  • NEWIN Manufacturing Base
  • Packaging & Shipping
  • Technical Strength& Standards
  • Certifications
Overview

Basic Info.

Model NO.
NWF Series
Cooling Method
Mixed Flow
Ventilation Mode
Mixing Ventilation
Material
Hdgs or SUS
Air Contact Form
Wet and Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE, CTI
Condition
New
Water Capacity
150m3/H
Inlet/Outlet Temperature
37/32c
Case Material
Galvanized Steel Plate
Coil Material
SUS304/ Copper
Pump
Minamoto
Transport Package
Wood Packing, 20gp, 40gp Container Loading
Specification
CE, UL, CTI
Trademark
NEWIN
Origin
Shenzhen China
HS Code
84195000
Production Capacity
1000sets/Month

Product Description

NEWIN NWF Series Mixed Flow Series Closed Circuit Cooling Tower

NWF series closed cooling tower employs efficient composite flow cooling technology, stable operation, energy saving and environmental friendly. Once the spray water has cooled the heat exchange coil, it is channeled into the cold water basin through the PVC heat exchange layer, effectively reducing the temperature within the tower and minimizing noise caused by straight falling spray water into the bottom basin.

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
High-Efficiency Mixed Flow Closed Circuit System

Operation
The fluid medium requiring cooling flows through the efficient serpentine coil heat exchanger. A continuous external spray system moistens the coil surface to facilitate cooling, allowing the cooled medium to exchange heat with the spray water through a partition wall heat exchanger, creating a closed loop for effective cooling. Low-temperature dry air enters the tower laterally and intersects vertically with the direction of the spray water flow, forming a composite heat transfer powered by fans. Once the air and spray water have fully exchanged heat, high-temperature saturated air is discharged outside of the tower while the spray water undergoes secondary heat transfer through a PVC heat exchange layer before falling into a water collection basin, effectively removing more heat for superior cooling efficiency.
 
Advantage
> The Mixed flow close-loop circulation system guarantees the purity of the media, diminishes expenses for maintenance, and conserves precious water resources while the efficient cooling.
> The combination of a stainless steel coil heat exchanger and PVC heat exchange layer is not only efficient, but also elegant. This innovative design maximizes the heat transfer area, enhances heat exchange efficiency, and even contributes to noise reduction.
> The single-side air intake design reduces noise emissions at the rear of the tower, making it ideal for use in noise-sensitive environments.
> The product has a compact structure and space-saving design, allowing for the combination of multiple cooling towers.
Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
Features

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
COOLING TOWER PARTS

1. Axial Flow Fan
The aluminum alloy axial flow fan operates with low noise, stability, and efficiency. The motor is equipped with a protection grade of IP55 and an insulation grade of F, ensuring heightened safety and reliability.

2. External Spray System
Spray cool water into heat exchange coil,continuously wets the surface of the coil for cooling.

3. Stainless Steel Heat Exchange Coil
Stainless steel coils exhibit superior heat exchange efficiency, enhanced corrosion resistance, light weight, prolonged equipment lifespan, and are environmentally sustainable due to their recyclability.

4. MAH PVC Fill Film ( PVC heat exchange layer)
The PVC filler heat exchange layer utilizes an integrated design of filler, air inlet grille, and drift eliminator to guarantee consistent air intake, significantly minimize water drift loss, and ensure optimal heat transfer performance. Furthermore, the unique surface texture provides ample heat exchange surface area, thereby enhancing overall efficiency. The filler could be upgraded to high-temperature materials to align with the specific working conditions of the project.

5. MBD PVC Drift Eliminator
The exclusive drift eliminatordesigned for closed cooling towers is adept at efficiently extracting airborne water droplets, boasting minimal wind resistance and an impressive capture rate of 99.99%, thus guaranteeing optimal heat transfer performance.

6. Air Inlet Louver
Ensure cool dry air evenly sucked in and passed through the coil and the PVC heat exchange layer, Limiting sun exposure and microbial growth.

7. Heavy-duty construction
 The high-quality Z700 galvanized steel frame and shell,offering corrosion resistance. For particularly harsh environments, the optional SUS314/316 or NWN-Armour anti-corrosion coated steel provides exceptional protection.

8. Access Door
Into the tower inner maintenance platform through the access door. The presence of an inspection platform within the cooling tower enhances the convenience of conducting inspections and maintenance.

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
Product Parameters

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower

Design Conditions
 
NWF Dimension (mm) Weight (kg)
Model L W H Dry Wet
NWF-120-Z7-S 2300 1910 2850 843 1935
NWF-180-Z7-S 2300 1910 2930 883 2006
NWF-230-Z7-S 2850 2110 2930 1140 2701
NWF-290-Z7-S 3550 2110 2930 1377 3396
NWF-350-Z7-S 4150 2110 2930 1601 4013
NWF-450-Z7-S 4550 2250 3480 2055 4706
NWF-600-Z7-S 4550 2250 3720 2197 4899
NWF-750-Z7-S 5200 2250 4270 3201 6920
NWF-900-Z7-S 5200 2250 4490 3549 7535
NWF-1000-Z7-S 5200 2870 4490 4045 8589
NWF-1150-Z7-S 5900 2870 4540 4536 9677
NWF-1450-Z7-S 5900 3150 4690 5321 12230
NWF-1750-Z7-S 6500 3150 4690 5943 13744
NWF-2300-Z7-S 7500 3250 4900 6963 15214

Optional Various Additional Functions
Two-speed& VFD variable frequency motor/ Vibration Cut-off Switch/ Electronic descaler/ Water treatment equipment/ Anti-freeze automatic heating system/ Noise reduction upgrade/ External maintenance platform and guardrail/Installation and maintenance boom etc.

 

Cost-effective Anti-Corrosion Solution
NWN-Armour Anti-corrosion Technology

Products coated with NWN-Armour anti-corrosion coating exhibit outstanding resistance to corrosion, approaching the qualities of stainless steel. They serve as a cost-effective alternative to stainless steel.
Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower

 

Application

Energy industry • Pharmaceutical industry • HVAC • Chemical industry • Machinery manufacturing • Metal processing • Plastic products • Industrial cooling • Food processing 

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
 
NEWIN Manufacturing Base

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
NEWIN FACTORY 
Manufacturing base Situated In Huizhou, Guangdong. It Covers An Area Of 10,000 Square Meters.

ISO CERTIFICATION
ISO9001:2015 Quality Manergement System Certification ISO14001:2015 Environmental Manergement System Certification

WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop

TESTING
Independent Testing LAB

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
NEWIN COOLING TOWERS:

· NWN/ NWF/ NCFN Closed Type Cooling Tower Series
· NSH/ NST Open Type Cooling Tower Series
· NTG Industrial Type Cooing Tower Series
· NECN/NECH Evaporative condenser
· NWFL Dry Air Cooler

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
NEWIN manufactures and stocks all major cooling tower accessories to meet maintenance and replacement needs of almost any size and types of cooling tower. Please contact us to customize the cooling tower accessories you need. 

CONTAIN:
· Fan drive system (fan/ fan stack/reducer/motor/shaft etc.)
· Water distribution (nozzles/ drift eliminator etc.)
· Heat exchange(PVC infills/ cooling coil etc.)
· Other accessories (air inlet louver/ valve etc.)
 
Packaging & Shipping

Open type cooling towers shipment

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
Closed type cooling towers shipment
Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
Technical Strength& Standards

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower
Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower

Certifications

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling TowerNewin Nwf Series Mixed Flow Series Closed Circuit Cooling TowerNewin Nwf Series Mixed Flow Series Closed Circuit Cooling TowerNewin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower

Newin Nwf Series Mixed Flow Series Closed Circuit Cooling Tower

 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier