Eco-Friendly Smart Dosing Control for Sustainable Cooling Water Management
Product Description
NEWIN has launched the all-new "Water Trace" series automatic chemical concentration monitoring and dosing system, featuring fluorescence sensor technology at its core and specifically designed for recirculating cooling water systems. The system uses an online fluorescence sensor to detect the concentration of fluorescent chemicals in the water in real time every three seconds, and leverages intelligent chemical control technology to achieve closed-loop feedback control-automatically adjusting the dosing pump's output to ensure the chemical concentration remains consistently within the set range. This system effectively addresses the dosing control challenges of both phosphorus-free and phosphorus-containing formulations, providing reliable and stable chemical dosing. It helps users optimize chemical usage, reduce operating costs, and achieve optimal water treatment performance.
This system effectively solves the dosing control challenges of both phosphorus-free and phosphorus-containing formulations, providing stable and reliable chemical dosing assurance. It helps users optimize chemical dosages, reduce operating costs, and achieve optimal water treatment performance.
Key characteristics of NEWIN's specialized fluorescent tracer include:
Innovative molecular architecture - Boasting high fluorescence efficiency with only a concentration of 100 ppb required for dependable detection and consistent control.
Exceptional solubility - Remaining colorless in both concentrated and dosed states, ensuring no visual impact or color alteration in water treatment chemicals.
Inert fluorescent tracer - Neutral pH with excellent compatibility with treatment chemicals, ensuring no adverse chemical reactions or incompatibility, and preserving system pH balance.
Superior fine particle management - Dust-free mixing enhances operational safety and ease, contributing to a seamless operational experience.
Remarkable long-term stability - Featuring a shelf life exceeding one year in original packaging, with no decomposition or degradation, ensuring enduring reliability.
Advantages
Installation - No special tools required for installation or removal.
Easy Operation - 4-20 mA and Modbus RTU outputs; automatic color/turbidity compensation; downloadable historical data.
Easy Maintenance - 5-minute cleaning; typically no additional maintenance needed within 3 months.
Anti-Interference - Automatic color/turbidity compensation ensures readings are unaffected by color or turbidity; also provides accurate turbidity measurement (error <10% for >15 NTU).
High Stability & Accuracy - High-temperature/high-humidity resistant filters and ultra-narrow bandwidth gallium phosphide (GaP) technology ensure accurate and stable test data for NEWIN's dedicated fluorescent tracer.
Parameter

| |
Water Trail Series (ANTRA Series) |
| Main Technical Requirements |
Work Pressure |
0.2-1.0MPa |
| Operating Temperature |
0-50ºC |
| Equipment Protection Grade |
IP55 |
| Recommended Ambient Temperature |
0~30ºC |
| Relative humidity |
<85% |
| Number of Sensor Connections |
2-10 |
| Dosing Control Quantity |
standard configuration: 2 channels, expandable to 3 channels |
| Touch Screen Specifications |
7" color touch screen, resolution 1024*600 |
| Cloud Remote Control Service |
support |
| Historical Data Storage |
yes |
| 3G/4G Access |
support |
| Monitoring & Control System |
Drug Concentration Meter |
accuracy 1ppm, RS485 output |
| Conductance |
measuring range 0-10000uS/cm, RS485 output |
| pH Optional |
measurement range 0-14, RS485 output |
| ORP Optional |
measurement range ±1500mV, RS485 output. |
| Flow Meter |
float magnetic induction type, low flow alarm |
| Related Parameters |
Pipeline Standard |
American standard, industrial grade UPVC, SCH80, modular design, fully connected by order |
| Inlet And Outlet Pipe Size |
(DN20-DN50), NPT internal thread |
| Size of Sewage Outlet |
(DN20-DN50) |
| Size of Dosing Pipeline |
1/2" (DN15), NPT internal thread |
| Filter |
self-cleaning device, filtration precision 100um |
| Hanging Rack |
Industrial grade quick connector, 2 groups with a total of 3 mounting positions, suitable for Type II mounting positions |
| Overall Size |
designed according to customer site (cabinet integrated type) |
| Equipment Net Weight |
50-100kg |
| Supply Voltage |
AC220V/50HZ/1P |
| Power Consumption |
<500w (excluding dosing pump load) |
NEWIN Manufacturing Base

NEWIN FACTORY
Discover the impressive and expansive manufacturing base of NEWIN, strategically nestled in the bustling industrial heartland of Huizhou, Guangdong. This state-of-the-art facility stretches over a substantial 10,000 square meters, dedicated to achieving excellence in every aspect of production.
ISO CERTIFICATION
NEWIN is proud to uphold the pinnacle of industry standards with ISO9001:2015 Quality Management System Certification and ISO14001:2015 Environmental Management System Certification. These certifications ensure our unwavering commitment to impeccable quality and sustainable practices.
WORKSHOPS
Welding Workshop
Filler Thermoforming Workshop
Sheet Metal Processing Workshop
Cooling Tower Assembly Workshop
TESTING
Independent Testing LAB
NEWIN COOLING TOWERS:
·
NWN/ NWF/ NCFN Introducing the Revolutionary Closed Type Cooling Tower Series, meticulously engineered for optimal efficiency and outstanding performance.
·
NSH/ NST Experience the Innovative Open Type Cooling Tower Series, expertly designed for versatility and dependable reliability in diverse applications.
·
NTG Presenting the Robust Industrial Type Cooling Tower Series, masterfully crafted for heavy-duty cooling solutions.
·
NECN/NECH Advanced Evaporative Condenser, offering exceptional thermal management and superior energy efficiency.
·
NWFL Explore the Efficient Dry Air Cooler, delivering reliable performance across varied cooling requirements.
At NEWIN, we specialize in manufacturing and maintaining a comprehensive inventory of essential cooling tower accessories. Our products are always ready to meet the diverse maintenance and replacement demands for any size or type of cooling tower. Connect with us for customized solutions tailored precisely to your specific requirements.
CONTAIN:
· Comprehensive Fan Drive System (including fan, fan stack, reducer, motor, shaft, etc.)
· Advanced Water Distribution Components (featuring nozzles, drift eliminator, etc.)
· Superior Heat Exchange Elements (such as PVC infills, cooling coil, etc.)
· Additional Accessories (including air inlet louver, valve, etc.)
Packaging & Shipping
Open Type Cooling Towers Shipment: At Newin, we recognize that the journey is as crucial as the destination itself. This understanding drives us to ensure our remarkable open type cooling towers are packaged with exceptional care and precision. Each unit is meticulously encased to withstand the trials of transportation, ensuring that what reaches your doorstep is not just a shipment, but a deliverance of unparalleled quality. Our shipping solutions are meticulously crafted to align with our esteemed standards, guaranteeing your equipment arrives in pristine condition, a testament to our unwavering dedication to excellence.
Closed Type Cooling Towers Shipment: At Newin, we take immense pride in our detailed and careful packaging process for closed type cooling towers. Each unit is crafted with meticulous precision and unparalleled attention to detail, ensuring safe arrival at its final destination-fully intact and primed for optimal performance. By selecting Newin, you're aligning with a partner devoted to excellence, not just through our superior products, but in every interaction and phase of your journey with us. Trust us to meet your needs and receive not merely a product, but a firm assurance of our commitment to delivering superior quality at every step.
Technical Strength& Standards


Certifications